1、 Standard Practice Multiphase Flow Internal Corrosion Direct Assessment (MP-ICDA) Methodology for Pipelines This NACE International standard represents a consensus of those individual members who have reviewed this document, its scope, and provisions. Its acceptance does not in any respect preclude
2、anyone, whether he or she has adopted the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not in conformance with this standard. Nothing contained in this NACE International standard is to be construed as granting any right, by implication or o
3、therwise, to manufacture, sell, or use in connection with any method, apparatus, or product covered by Letters Patent, or as indemnifying or protecting anyone against liability for infringement of Letters Patent. This standard represents minimum requirements and should in no way be interpreted as a
4、restriction on the use of better procedures or materials. Neither is this standard intended to apply in all cases relating to the subject. Unpredictable circumstances may negate the usefulness of this standard in specific instances. NACE International assumes no responsibility for the interpretation
5、 or use of this standard by other parties and accepts responsibility for only those official NACE International interpretations issued by NACE International in accordance with its governing procedures and policies which preclude the issuance of interpretations by individual volunteers. Users of this
6、 NACE International standard are responsible for reviewing appropriate health, safety, environmental, and regulatory documents and for determining their applicability in relation to this standard prior to its use. This NACE International standard may not necessarily address all potential health and
7、safety problems or environmental hazards associated with the use of materials, equipment, and/or operations detailed or referred to within this standard. Users of this NACE International standard are also responsible for establishing appropriate health, safety, and environmental protection practices
8、, in consultation with appropriate regulatory authorities if necessary, to achieve compliance with any existing applicable regulatory requirements prior to the use of this standard. CAUTIONARY NOTICE: NACE International standards are subject to periodic review, and may be revised or withdrawn at any
9、 time in accordance with NACE technical committee procedures. NACE International requires that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of initial publication. The user is cautioned to obtain the latest edition. Purchasers of NACE Internat
10、ional standards may receive current information on all standards and other NACE International publications by contacting the NACE International FirstService Department, 15835 Park Ten Place, Houston, Texas 77084-5145 (telephone +1 281-228-6200). Approved 2016-02-12 NACE International 15835 Park Ten
11、Place Houston, Texas 77084-5415 +1 (281) 228-6200 ISBN 1-57590-333-4 2015, NACE International NACE SP0116-2016 Item No. 21402 _ Foreword This standard practice outlines a methodology to assess pipeline integrity because of the threat internal corrosion in onshore and offshore pipelines and other pip
12、ing systems that normally carry multiphase fluids (gas, water, and oil) termed multiphase flow internal corrosion direct assessment (MP-ICDA). Liquid separators (drips), compressing stations, vessels, and other equipment not related to pipelines are not included in this standard. This standard appli
13、es to pipelines, both onshore and offshore, containing carbon dioxide (CO2), hydrogen sulfide (H2S), oxygen (O2), and other corrosive species. Additionally, this standard applies to pipelines that continuously contain a liquid phase (water and condensate and/or oil and/or petroleum compounds), a pos
14、sible solids content of various mineral scales, biofilms, or corrosion product compounds, and a continuous gas phase with fluid conditions that are not specifically covered by NACE SP01101 for wet gas internal corrosion direct assessment (WG-ICDA). Additionally, solids may be included as a phase by
15、itself and may also be included in multiphase flow analysis of fluid streams. This standard is intended for use by pipeline operators, oil/gas producers (upstream), and other pipeline industry individuals who manage pipeline integrity (both onshore and offshore) for pipelines that are normally under
16、 multiphase loading conditions and are outside the scope of NACE SP0110,1 NACE SP0206,2 and NACE SP0208.3 The MP-ICDA methodology has been developed to meet the needs of pipeline operators and producers to assess the integrity of pipelines with respect to the internal corrosion threats posed by the
17、fluids. MP-ICDA is a structured process that combines pre-assessment, indirect inspections, detailed examination, and post-assessment to evaluate the impact of predictable pipeline integrity threats such as internal corrosion. Specifically, the goal of MP-ICDA is to identify locations with the great
18、est likelihood of internal corrosion and its influencing factors, such as water content, flow regime, liquid hold-up, flow velocities, temperature and pressure changes. These locations are exposed and examined in accordance with criteria established in Section 4. The results of these examinations ar
19、e used as a basis for assessing the condition and integrity of the remaining pipeline segments (those with less likelihood of corrosion). Direct assessment (DA) does not depend on the ability of a pipeline to undergo in-line inspection (ILI) by smart-pigging or pressure testing, making it most valua
20、ble to those pipelines unable to accept pigs or those that cannot be hydrostatically pressure tested. This standard is intended to provide an integrity assessment methodology for internal corrosion for pipelines where ILI cannot be performed; however, the MP-ICDA methodology may also serve, compleme
21、nt, or assist in those cases in which ILI was conducted or is contemplated to demonstrate the reliability of the ICDA process. It can also be used for optimizing the selection/justification, inspection frequency, or prioritization of pipelines that are subjected to ILI. In multiphase flow systems, s
22、ubregions of a pipeline that is identified within a region that are more susceptible to internal corrosion depend on the flow pattern that are defined by flow velocities, sudden changes of geometries, changes in elevation caused by the topography of the terrain, sharp elbows, expansions, changes in
23、internal diameter and other changes that may influence the hydrodynamics of the flow. Multiphase flow and flow regimes can be determined by the use of flow models that have a hydrocarbon phase envelope (water and hydrocarbon), and the interaction between the gas and liquid phase, and allow the predi
24、ction under flowing conditions that shows local temperature, pressure, and fluid composition for a pipeline. Depending on the flow (i.e., velocity, gas/liquid quality, temperature, pressure, wall surface conditions, etc.), and specific operating conditions, the effects of flow regimes are considered
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NACESP01162016MULTIPHASEFLOWINTERNALCORROSIONDIRECTASSESSMENTMPICDAMETHODOLOGYFORPIPELINESITEMNO21402PDF

链接地址:http://www.mydoc123.com/p-835801.html