KS L ISO 26845-2012 Chemical analysis of refractories-General requirements for wet chemical analysis atomic absorption spectrometry and inductively coupled plasma atomic emission s.pdf
《KS L ISO 26845-2012 Chemical analysis of refractories-General requirements for wet chemical analysis atomic absorption spectrometry and inductively coupled plasma atomic emission s.pdf》由会员分享,可在线阅读,更多相关《KS L ISO 26845-2012 Chemical analysis of refractories-General requirements for wet chemical analysis atomic absorption spectrometry and inductively coupled plasma atomic emission s.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、 KSKSKSKSKSKSKSK KSKSKS KSKSK KSKS KSK KS KS L ISO 26845 , KS L ISO 26845: 2012 2012 9 18 http:/www.kats.go.krKS L ISO 26845:2012 : ( ) ( ) () LH KCC ( ) : (http:/www.standard.go.kr) : :2012 9 18 2012-0442 : : ( 02-509-7270) (http:/www.kats.go.kr). 10 5 , . KS L ISO 26845:2012 i ii 1 1 2 1 3 .2 4 2
2、5 7 5.1 (stock reagents) 7 5.2 .15 6 .16 6.1 16 6.2 16 6.3 16 6.4 .16 7 17 8 .17 8.1 17 8.2 17 9 ( ) 17 9.1 .17 9.2 .17 9.3 .17 10 18 11 .18 12 .18 KS L ISO 26845:2012 20 KS L ISO 26845:2012 ii 2008 1 ISO 26845, Chemical analysis of refractories General requirements for wet chemical analysis, atomic
3、 absorption spectrometry(AAS) and inductively coupled plasma atomic emission spectrometry(ICP-AES) methods . KS L ISO 26845:2012 , Chemical analysis of refractories General requirements for wet chemical analysis, atomic absorption spectrometry and inductively coupled plasma atomic emission spectrome
4、try methods 1 ( ) , , , , , , , . KS L ISO 10058 1, KS L ISO 10058 2, KS L ISO 10058 3 KS L ISO 20565 1, KS L ISO 20565 2, KS L ISO 20565 3 KS L ISO 21079 1, KS L ISO 21079 2, KS L ISO 21079 3 KS L ISO 21587 1, KS L ISO 21587 2, KS L ISO 21587 3 2 . . ( ) . KS A 5101 1, 1: KS A ISO 31 0, 0: KS L 001
5、1, KS M 0016, KS M 0032, KS M 8379, ( ) KS M ISO 6353 1, 1: KS M ISO 6353 2, 2: 1 KS M ISO 6353 3, 3: 2 KS M ISO 6955, , , ISO 5022, Shaped refractory products Sampling and acceptance testing ISO 8656 1, Refractory products-Sampling of raw materials and unshaped products Part 1: Sampling scheme KS L
6、 ISO 26845:2012 2 3 , KS L 0011 . 3.1 ( ) 3.2 ( ) 3.3 - - (1 %80 %, ), ( )(5 %50 %, ) (IV)(0.1 %45 %, ) 4 4.1 4.1.1 (Atomic absorption spectrometer; AAS) KS M 0016 . - . 4.1.2 (Flame emission spectrophotometer) . 4.1.3 (Inductively coupled plasma atomic emission spectro-meter, ICP-AES) 4.1.4 (Molecu
7、lar absorption spectrometer) KS M ISO 6286 . 4.1.5 (Photometer) 1 cm . 4.2 4.2.1 KS L ISO 26845:2012 3 (Mecker) (Bunsen) 4.2.2 1 150 C . 4.2.3 ( ) 4.2.4 ( ) . 4.3 4.3.1 0.1 mg . 4.3.2 . 4.3.3 . 4.3.4 (10 mm) ( 12 mm200 mm) . divinylbenzene(DVB) 8 %, 75 m150 m 18 mL . 1.0 mL1.5 mL . (1 2) 120 mL 70 m
8、L . 1 . KS L ISO 26845:2012 4 : mm 1 2 3 1 4.4 . 4.4.1 , 20 mL 30 mL 4.4.2 , . 75 mL 150 mL . 4.5 4.5.1 0.1 mL 50 mL . 90 KS L ISO 26845:2012 5 4.5.2 , 500 mL, 1 000 mL 4.5.3 . 4.5.4 , 500 mL 4.5.5 50 mL, 100 mL, 200 mL, 300 mL, 400 mL, 500 mL . 4.5.6 . 4.5.7 2 . : mm a) b) 1 2 3 2 KS L ISO 26845:20
9、12 6 4.5.8 . 250 mL, 500 mL 4.5.9 . 100 mL, 250 mL, 500 mL, 1 000 mL 4.5.10 , 5 mL 4.5.11 75 mm . 4.6 4.6.1 125 mm . 4.6.2 , 15 mL 4.7 4.7.1 , 100 mL 4.7.2 (PTFE) 200 mL. 2 . PTFE 150 mL . 4.7.3 . . a) b) , . (1 mm2) 20 . . 1 mg . (B) . (A) . (C), (C) (kPa) . (B) , S . 20)(000 0001BABmmmmmfS+= KS L
10、ISO 26845:2012 7 mA : (A) (mg) , ; mA mB (A) (B) ; mB : (B) (mg) , ; m : (mg), : 20 C, 101.325 kPa(760 mmHg) m : (mg), : 20 C , 101.325 kPa(760 mmHg) 1 C 4.0 mg , 0.133 kPa 1.3 mg . f : 100 . . 4.8 4.8.1 1 100 C . 4.8.2 4.8.3 pH . 5 , . KS M ISO 6353 1, KS M ISO 6353 2, KS M ISO 6353 3 . . 5.1 (stoc
11、k reagents) 5.1.1 (KS M ISO 6353 2, R1) 99.7 %( ) 5.1.2 (Al 25 mg/mL) 123.5 g 1 000 mL . 5.1.3 (Al2O310 mg/mL) KS L ISO 26845:2012 8 99.9 %( ) 5.3 g 300 mL . (1 1) 250 mL . 30 mL . 1 000 mL . 5.1.4 (KS M ISO 6353 2, R3) 25 %( ) 5.1.5 (1 1) 1: 1 . 5.1.6 (1 9) 1: 9 . 5.1.7 120 mL 500 mL (5.1.4) 74 mL
12、. 1 000 mL . 5.1.8 (100 g/L) 100 g 1 000 mL . 5.1.9 (200 g/L) 200 g 1 000 mL . 5.1.10 5.1.11 (20 g/L) 10 g 500 mL , (1 9)(5.1.6) . (1 9) . 5.1.12 (10 g/L) ammonium ceric nitrate, (NH4)2Ce(NO3)6 5 g 200 mL . 7 mL 500 mL . 5.1.13 (100 g/L) -4 (ammonium molybdate tetrahydrate) 10 g 100 mL , . . 4 . 5.1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- KSLISO268452012CHEMICALANALYSISOFREFRACTORIESGENERALREQUIREMENTSFORWETCHEMICALANALYSISATOMICABSORPTIONSPECTROMETRYANDINDUCTIVELYCOUPLEDPLASMAATOMICEMISSIONSPDF

链接地址:http://www.mydoc123.com/p-819000.html