ITU-T K 65-2011 Overvoltage and overcurrent requirements for termination modules with contacts for test ports or surge protective devices (Study Group 5)《具有测试端口和电涌保护器的端接模块的超电压及过载电流.pdf
《ITU-T K 65-2011 Overvoltage and overcurrent requirements for termination modules with contacts for test ports or surge protective devices (Study Group 5)《具有测试端口和电涌保护器的端接模块的超电压及过载电流.pdf》由会员分享,可在线阅读,更多相关《ITU-T K 65-2011 Overvoltage and overcurrent requirements for termination modules with contacts for test ports or surge protective devices (Study Group 5)《具有测试端口和电涌保护器的端接模块的超电压及过载电流.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、 International Telecommunication Union ITU-T K.65TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (01/2011) SERIES K: PROTECTION AGAINST INTERFERENCE Overvoltage and overcurrent requirements for termination modules with contacts for test ports or surge protective devices Recommendation ITU-T K.65 Rec
2、. ITU-T K.65 (01/2011) i Recommendation ITU-T K.65 Overvoltage and overcurrent requirements for termination modules with contacts for test ports or surge protective devices Summary Recommendation ITU-T K.65 specifies the overvoltage requirements and test procedures for termination modules, with cont
3、acts for test ports or surge protective devices (SPDs), used for symmetric pair conductors subjected to overvoltages and overcurrents. Overvoltages or overcurrents covered by this Recommendation include surges due to lightning on or near the line plant, short-term induction of alternating voltages f
4、rom adjacent power lines or railway systems, earth potential rise due to power faults, and direct contacts between telecommunication lines and power lines. Major changes compared with the 2004 version of this Recommendation include: the addition of a mains contact test to the equipment side of a mod
5、ule with series elements; a reduction of the current magnitude for test Figure C.2 and for the customer side test for test Figure C.3 (tests 2.2 and 2.3); a revision of Figure E.1 10/350 s current generator to be in line with Recommendation ITU-T K.44, Figure II.4-1 10/350 s current surge generator;
6、 the addition of information on the use of fail-safes; the addition of a coordination test, for modules with series elements, to check that surges under the firing voltage of the gas discharge tube (GDT) will not damage the series elements; the addition of a high voltage a.c. test to simulate a volt
7、age 230 V a.c. which will operate a 600 V GDT. History Edition Recommendation Approval Study Group 1.0 ITU-T K.65 2004-12-14 5 2.0 ITU-T K.65 2011-01-13 5 ii Rec. ITU-T K.65 (01/2011) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of te
8、lecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing tele
9、communications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the
10、procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a
11、telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all
12、of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGH
13、TS ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU
14、 members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this m
15、ay not represent the latest information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2011 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T K
16、.65 (01/2011) iii Table of Contents Page 1 Scope 1 2 References. 2 3 Definitions 2 3.1 Terms defined elsewhere 2 3.2 Definitions 2 4 Abbreviations 8 5 Conventions 8 6 Service and test conditions . 8 6.1 Service conditions 8 6.2 Test temperature and humidity . 9 6.3 Termination module and SPD testing
17、 . 9 6.4 Termination module preparation 9 6.5 Test methods . 10 6.6 Termination module/SPD performance: pass/failure criteria . 10 6.7 Determining the required tests 11 6.8 Acceptance test requirements for termination modules/SPDs in MDFs which meet certain conditions 11 7 General requirements 12 7.
18、1 Manufacturer declaration 12 7.2 Use of fail-safes 12 7.3 Breakdown voltage of the termination . 12 7.4 Caution . 12 7.5 Ball bearings . 13 Annex A Dimensioning of terminating wires for all voltage/current tests . 19 Annex B Connection details for voltage tests on termination modules 20 Annex C Con
19、nection details for current tests on termination modules 25 Annex D Test method for tests in aqueous solution . 29 Annex E 30 Appendix I Information on how to test termination modules with SPDs . 31 I.1 Introduction 31 I.2 Termination modules used in the access network 31 I.3 Termination modules use
20、d in MDFs in operator buildings and customer premises 32 iv Rec. ITU-T K.65 (01/2011) Page Appendix II Application . 34 II.1 Environment . 34 II.2 Termination module and SPD types . 34 II.3 Dry termination module and SPD tests 34 II.4 Filled termination module and SPD tests . 34 II.5 Application . 3
21、4 Bibliography. 35 Rec. ITU-T K.65 (01/2011) 1 Recommendation ITU-T K.65 Overvoltage and overcurrent requirements for termination modules with contacts for test ports or surge protective devices 1 Scope This Recommendation specifies the requirements and test procedures for termination modules with c
22、ontacts for test ports or SPDs (see clause 3.2.15) used for symmetric pair conductors subjected to overvoltages and overcurrents. Note, other Recommendations exist, such as ITU-T K.12 and ITU-T K.28, specifying characteristics for surge protective components (SPCs). An example of where termination m
23、odules included in the scope of this Recommendation may be used is given in Figure 1. The following types of terminating modules covered by this Recommendation are: a termination module with terminals but without the facility for an SPD; a termination module with terminals and the facility for an SP
24、D; an integral termination module/SPD. The termination module and SPD are not meant to be separated. This Recommendation does not cover the requirements of termination modules used in equipment. These are covered by the relevant equipment Recommendations, i.e., b-ITU-T K.20, b-ITU-T K.21 or b-ITU-T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTK652011OVERVOLTAGEANDOVERCURRENTREQUIREMENTSFORTERMINATIONMODULESWITHCONTACTSFORTESTPORTSORSURGEPROTECTIVEDEVICESSTUDYGROUP5

链接地址:http://www.mydoc123.com/p-799285.html