ITU-T K 64-2016 Safe working practices for outside equipment installed in particular environments (Study Group 5)《对于安装在特殊环境中的外部设备的安全工作实践(研究组5)》.pdf
《ITU-T K 64-2016 Safe working practices for outside equipment installed in particular environments (Study Group 5)《对于安装在特殊环境中的外部设备的安全工作实践(研究组5)》.pdf》由会员分享,可在线阅读,更多相关《ITU-T K 64-2016 Safe working practices for outside equipment installed in particular environments (Study Group 5)《对于安装在特殊环境中的外部设备的安全工作实践(研究组5)》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T K.64 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (06/2016) SERIES K: PROTECTION AGAINST INTERFERENCE Safe working practices for outside equipment installed in particular environments Recommendation ITU-T K.64 Rec. ITU-T
2、 K.64 (06/2016) i Recommendation ITU-T K.64 Safe working practices for outside equipment installed in particular environments Summary Recommendation ITU-T K.64 describes working practices for service personnel to help them work safely in telecommunication installations in three specific environments
3、. The specific environments covered in this Recommendation are characterized by wet conditions or close proximity to exposed metallic parts. The working practices apply to telecommunication plants with voltage levels higher than the limits defined for analogue PSTN circuits, such as remote feeding t
4、elecommunication current or voltage (RFT-C or RFT-V) circuits. This version of Recommendation ITU-T K.64 includes a warning regarding contact with terminals carrying RFT circuits with small parts of the body, e.g., back of the hand. The references have been updated. History Edition Recommendation Ap
5、proval Study Group Unique ID* 1.0 ITU-T K.64 2004-02-29 5 11.1002/1000/7147 2.0 ITU-T K.64 2011-01-13 5 11.1002/1000/11035 3.0 ITU-T K.64 2016-06-29 5 11.1002/1000/12874 Keywords K.50, RFT, RFT-C, RFT-V, safe, TNV, work practices. * To access the Recommendation, type the URL http:/handle.itu.int/ in
6、 the address field of your web browser, followed by the Recommendations unique ID. For example, http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T K.64 (06/2016) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunication
7、s, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications
8、on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid
9、down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommunicati
10、on administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandat
11、ory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTSITU draws att
12、ention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or othe
13、rs outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent
14、 the latest information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2016 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T K.64 (06/2016) ii
15、i Table of Contents Page 1 Scope . 1 2 References . 1 3 Definitions 1 4 Abbreviations and acronyms 2 5 Telecommunication particular workplaces . 3 6 Voltage levels on TLC installations . 3 7 Work practices on TLC plants in particular environments . 5 7.1 Switching off the power supply 5 7.2 Practice
16、s to be used when working on live telecommunication circuits 5 8 Work on telecommunication installations at risk of electric shock 7 8.1 Work on equipment or devices (terminal box, etc.) . 7 8.2 Work on cables . 8 Appendix I Rationale of safe voltage limit values for workplace at major risk of elect
17、ric shock . 9 I.1 Operating cases . 9 I.2 Calculation assumption 9 I.3 Limit current calculation 11 I.4 Voltage limit calculation 14 Bibliography. 17 iv Rec. ITU-T K.64 (06/2016) Introduction Network operators, in their telecommunication infrastructure, use equipment that is remotely powered by symm
18、etrical or coaxial pair cables. The voltages and currents that power these systems differ among them, and comply with the limit values defined in standards IEC 60950-1 and IEC 60950-21 for symmetrical pair cables and in standard IEC 60728-11 for coaxial cables. The limits in these standards have bee
19、n defined to allow service personnel to work safely on these lines without de-energizing the circuits. Nevertheless, there are telecommunication environments that necessitate additional precautions to enable service personnel to work safely on circuits that are usually considered safe to touch. Thes
20、e environments are characterized as wet conditions, sometimes associated with standing water. This Recommendation lists three practical situations where additional precautions are needed and defines how the service personnel should perform work to reduce risk associated with these situations. Specif
21、ic applications, local conditions or regulations may give rise to a need for additional safeguards or modifications to practices presented in this Recommendation. Rec. ITU-T K.64 (06/2016) 1 Recommendation ITU-T K.64 Safe working practices for outside equipment installed in particular environments 1
22、 Scope The scope of this Recommendation is to provide working procedures for maintenance activities in specific environments for telecommunication plants with voltage levels higher than the limits defined for analogue public switched telephone network (PSTN) circuits. The specific environments cover
23、ed in this Recommendation are characterized by wet conditions or close proximity to exposed metallic parts. 2 References The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of pub
24、lication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTK642016SAFEWORKINGPRACTICESFOROUTSIDEEQUIPMENTINSTALLEDINPARTICULARENVIRONMENTSSTUDYGROUP5 对于 安装

链接地址:http://www.mydoc123.com/p-799284.html