《ITU-T G 951-1988 DIGITAL LINE SYSTEMS BASED ON THE 1544 KBIT S HIERARCHY ON SYMMETRIC PAIR CABLES《在对称线对电缆上以1544kbit s系列为基础的数字线路系统 数字网络、数字区域和数字线路系统(研究组XV和XVIII)》.pdf》由会员分享,可在线阅读,更多相关《ITU-T G 951-1988 DIGITAL LINE SYSTEMS BASED ON THE 1544 KBIT S HIERARCHY ON SYMMETRIC PAIR CABLES《在对称线对电缆上以1544kbit s系列为基础的数字线路系统 数字网络、数字区域和数字线路系统(研究组XV和XVIII)》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU$)4!,G0G03%#4)/.3G0G0!.$G0G0$)4!,G0G0,).%G0G03934%-3$)4!,G0G0,).%G0G03934%-3G0G0“!3%$/.G0G04(%G0G0 G0+“)4 3G0G0()%2!2#(9/.G0G039-%42)#G0G00!)2G0G0#!“,%3)45G134G0G0RecommendationG0G0 (Extract from the “LUEG0“OOK
2、)NOTES1 ITU-T Recommendation G.951 was published in Fascicle III.5 of the Blue Book. This file is an extract from theBlue Book. While the presentation and layout of the text might be slightly different from the Blue Book version, thecontents of the file are identical to the Blue Book version and cop
3、yright conditions remain unchanged (see below).2 In this Recommendation, the expression “Administration” is used for conciseness to indicate both atelecommunication administration and a recognized operating agency. ITU 1988, 1993All rights reserved. No part of this publication may be reproduced or u
4、tilized in any form or by any means, electronic ormechanical, including photocopying and microfilm, without permission in writing from the ITU.Fascicle III.5 - Rec. G.951 1Recommendation G.951DIGITAL LINE SYSTEMS BASED ON THE 1544 KBIT/S HIERARCHYON SYMMETRIC PAIR CABLES(Malaga-Torremolinos, 1984; a
5、mended at Melbourne, 1988)1 GeneralThis Recommendation covers digital line systems for the transmission of signals based on the 1544 kbit/shierarchy on symmetric pair cables and includes systems operating at the following bit rates:1544 kbit/s,3152 kbit/s,6312 kbit/s.2 Transmission mediumThe system
6、can be operated on symmetrical pair cables of various wire diameters and cable constructionsincluding those given in Recommendations G.611, G.612, and G.613.3 Protection against interference from external sourcesThe digital line system can be disturbed by interference from telephone circuits carried
7、 within the same cableand by a switch when repeaters are installed in switching centres. Examples of possible ways of reducing the effect ofthis type of interference is the reduction of repeater section length near switching centres, segregation of pairs, the use ofparticular line codes, etc.4 Overa
8、ll design features4.1 AvailabilityThe availability objective of the system should be derived taking into account the availability requirement forthe hypothetical reference digital section as given in draft Recommendation G.801.4.2 ReliabilityMTBF values should be specified for the line system as a w
9、hole taking into account the requirementsconcerning availability.4.3 Repeater crosstalk-noise figuresRepeater crosstalk-noise figures are defined in Annex A, together with suggested measurement techniques.Crosstalk-noise figures quantify the performance of digital regenerators which are subject to c
10、rosstalk interference. Theyare functions of BER, line system line code, cable characteristics, environmental conditions, and repeater spacing loss A0(at half the line system baud rate).At a BER = 10-xand over a loss range Al A0 A2, crosstalk-noise figures should meet the followingspecifications:2 Fa
11、scicle III.5 - Rec. G.951a) NEXT-Noise Figure RN CA0+ D*b) FEXT-Noise Figure RF E* It has not been possible to recommend specific values for parameters x, A1, A2, C, D and E.4.4 Error PerformanceThe design objective for the error ratio of the individual repeater should take into account the networkp
12、erformance objectives given in Recommendation G.821.5 Specific design features5.1 Type of power feedingAlthough CCITT does not recommend the use of a specific remote power-feeding system for this symmetricalline system, in practice only the constant current d.c. feeding via the phantom circuits of t
13、he two symmetrical pairs of asystem is used.This symmetrical cable system may be subject to induced voltages and currents caused by lightning, powerlines, railways, etc.Precautions must be taken to protect the staff from any possible danger arising from the normal operatingvoltages and remote power-
14、feed currents as well as from the induced voltages and currents.Many national Administrations have issued detailed rules and regulations for the protection of persons. It isobligatory in most cases to meet these rules and regulations. In addition the CCITT Directives 1 give guidance on theseproblems
15、.Precautions are also needed for the protection of the equipment against induced voltages and currents. Theequipment should therefore be designed in such a way that it passes the tests specified in Recommendation K.17 2.5.2 Repeater spacing and cable fillThe specific repeater spacing cannot be recom
16、mended, but general considerations concerning system planningare contained in Annex B to this Recommendation.5.3 Maintenance strategy5.3.1 Type of supervision and fault locationIn service monitoring or out-of-service fault location can be used.5.3.2 Fault conditions and consequent actionsThe fault c
17、onditions and consequent actions in this section should be complementary to those recommended fordigital line sections.Fascicle III.5 - Rec. G.951 3ANNEX A(to Recommendation G.951)Definition and measurement of repeaters crosstalk noise figuresA.1 Definitiona) NEXT-Noise Figure RNRN = IN - N0IN= mean
18、 square near-end crosstalk (NEXT) voltage produced by a single interfering regeneratorthat would appear at the decision point if the NEXT loss were 0 dB at half the line system baudrate.N0= mean square NEXT interference voltage at decision point which procedures specified BER, anddepends on paramete
19、rs which affect the decision process and reflects impairments arising fromintersymbol interference and offsets from the optimum position of the decision threshold levelsand sampling instants at the regenerator decision point.E(f) = regenerator equalizer frequency transfer function.P(f) = power spect
20、ral density (single sided) of line system line code.f0= half line system baud rate.Quantities in square brackets are in dB, i.e.X = 10 log10| X |.b) FEXT-Noise Figure RFRF = IF - N0IF= mean square far-end crosstalk (FEXT) voltage produced by a single interfering regenerator thatwould appear at the d
21、ecision point if the FEXT loss were 0 dB at half the line system baud rate.N0= mean square FEXT interference voltage at decision point which produces specified BER, anddepends on parameters which affect the decision process and reflects impairments arising fromintersymbol interference and offsets fr
22、om the optimum position of the decision threshold levelsand sampling instants at the regenerator decision points.E(f), P(f), f0as in a), andG(f) = frequency transfer function of cable.4 Fascicle III.5 - Rec. G.951A.2 MeasurementMethod a) directly relates to the definition of crosstalk-noise figure a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTG9511988DIGITALLINESYSTEMSBASEDONTHE1544KBITSHIERARCHYONSYMMETRICPAIRCABLES 对称 电缆 1544 KBITS 系列 基础

链接地址:http://www.mydoc123.com/p-797021.html