ITU-R SM 1840-2007 Test procedure for measuring the sensitivity of radio monitoring receivers using analogue-modulated signals《测量使用模拟调制信号无线电监测接收机灵敏度的测试程序》.pdf
《ITU-R SM 1840-2007 Test procedure for measuring the sensitivity of radio monitoring receivers using analogue-modulated signals《测量使用模拟调制信号无线电监测接收机灵敏度的测试程序》.pdf》由会员分享,可在线阅读,更多相关《ITU-R SM 1840-2007 Test procedure for measuring the sensitivity of radio monitoring receivers using analogue-modulated signals《测量使用模拟调制信号无线电监测接收机灵敏度的测试程序》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 Recommendation ITU-R SM.1840(12/2007)Test procedure for measuring the sensitivity of radio monitoring receivers using analogue-modulated signalsSM SeriesSpectrum managementii Rec. ITU-R SM.1840 Foreword The role of the Radiocommunication Sector is to ensure the rational, equitable, efficient and ec
2、onomical use of the radio-frequency spectrum by all radiocommunication services, including satellite services, and carry out studies without limit of frequency range on the basis of which Recommendations are adopted. The regulatory and policy functions of the Radiocommunication Sector are performed
3、by World and Regional Radiocommunication Conferences and Radiocommunication Assemblies supported by Study Groups. Policy on Intellectual Property Right (IPR) ITU-R policy on IPR is described in the Common Patent Policy for ITU-T/ITU-R/ISO/IEC referenced in Annex 1 of Resolution ITU-R 1. Forms to be
4、used for the submission of patent statements and licensing declarations by patent holders are available from http:/www.itu.int/ITU-R/go/patents/en where the Guidelines for Implementation of the Common Patent Policy for ITU-T/ITU-R/ISO/IEC and the ITU-R patent information database can also be found.
5、Series of ITU-R Recommendations (Also available online at http:/www.itu.int/publ/R-REC/en) Series Title BO Satellite delivery BR Recording for production, archival and play-out; film for television BS Broadcasting service (sound) BT Broadcasting service (television) F Fixed service M Mobile, radiode
6、termination, amateur and related satellite services P Radiowave propagation RA Radio astronomy RS Remote sensing systems S Fixed-satellite service SA Space applications and meteorology SF Frequency sharing and coordination between fixed-satellite and fixed service systems SM Spectrum management SNG
7、Satellite news gathering TF Time signals and frequency standards emissions V Vocabulary and related subjects Note: This ITU-R Recommendation was approved in English under the procedure detailed in Resolution ITU-R 1. Electronic Publication Geneva, 2009 ITU 2009 All rights reserved. No part of this p
8、ublication may be reproduced, by any means whatsoever, without written permission of ITU. Rec. ITU-R SM.1840 1 RECOMMENDATION ITU-R SM.1840 Test procedure for measuring the sensitivity of radio monitoring receivers using analogue-modulated signals (2007) Scope This Recommendation belongs to a set of
9、 Recommendations describing the test methods to determine technical parameters of radio monitoring receivers that are important for the users of these receivers. When the described methods are followed by manufacturers, comparing different receivers is made easier. This Recommendation provides the d
10、efinition of a sensitivity test procedure for receivers. This test procedure definition is recommended to all the manufacturers, with the advantage for the users of such receivers, that an easier and more objective assessment of product quality is possible. The ITU Radiocommunication Assembly, consi
11、dering a) that ITU-R has published the Typical recommended specifications for analogue and digital monitoring receivers in the Spectrum Monitoring Handbook (2002), but that nothing is said about the test procedures behind such specifications; b) that one of the specifications that most strongly depe
12、nds on the test procedures applied is the sensitivity; c) that the sensitivity of a receiver is a measure of its ability to receive weak signals and to produce an output having a usable level and acceptable quality; d) that the sensitivity level specified in the data sheet of a receiver depends extr
13、emely on the test frequencies used, the modulation parameters, the IF filter bandwidth used, the signal-to-interference ratio including noise and distortion (SINAD) value and the ambient temperature prevailing during the tests; e) that due to the direct correlation with the noise figure the sensitiv
14、ity characteristic has a direct influence on the suitability of a receiver as a monitoring device; f) that without a defined test procedure, the sensitivity specifications published by the manufacturers have to be made comparable by some kind of conversion and that this conversion might be complex o
15、r even impossible to perform; g) that a defined test procedure for the sensitivity must be independent of receiver design; h) that a well-defined test procedure for the sensitivity, if adopted by all the manufacturers of radio monitoring receivers, will have the advantage for the users of such recei
16、vers, that an easier and more objective assessment of product quality is possible, avoiding ambiguities; j) that supplementary information about these sensitivity measurements can be found in the Report ITU-R SM.2125 Parameters of and measurement procedures on H/V/UHF monitoring receivers and statio
17、ns, 2 Rec. ITU-R SM.1840 recommends 1 that for cases in which the sensitivity of radio monitoring receivers using analogue-modulated signals is specified by administrations, the measurement method in Annex 1 should be used. Annex 1 Test procedure for measuring the sensitivity of radio monitoring rec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITURSM18402007TESTPROCEDUREFORMEASURINGTHESENSITIVITYOFRADIOMONITORINGRECEIVERSUSINGANALOGUEMODULATEDSIGNALS

链接地址:http://www.mydoc123.com/p-794109.html