ISA 67 01 01-2002 Transducer and Transmitter Installation for Nuclear Safety Applications《核安全应用程序的长安器和发射机安装[代替 ISA 67 01]》.pdf
《ISA 67 01 01-2002 Transducer and Transmitter Installation for Nuclear Safety Applications《核安全应用程序的长安器和发射机安装[代替 ISA 67 01]》.pdf》由会员分享,可在线阅读,更多相关《ISA 67 01 01-2002 Transducer and Transmitter Installation for Nuclear Safety Applications《核安全应用程序的长安器和发射机安装[代替 ISA 67 01]》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、Transducer and TransmitterInstallation for Nuclear SafetyApplicationsReaffirmed 16 September 2002ANSI/ISA67.01.012002Formerly ANSI/ISA67.011994AMERICAN NATIONAL STANDARDISA The Instrumentation,Systems, andAutomation Society TMANSI/ISA-67.01.01-2002Transducer and Transmitter Installation for Nuclear
2、Safety ApplicationsISBN: 1-55617-837-9Copyright 2002 by ISA The Instrumentation, Systems, and Automation Society. All rights reserved.Not for resale. Printed in the United States of America. No part of this publication may be reproduced,stored in a retrieval system, or transmitted in any form or by
3、any means (electronic mechanical,photocopying, recording, or otherwise), without the prior written permission of the Publisher.ISA67 Alexander DriveP.O. Box 12277Research Triangle Park, North Carolina 27709- 3 - ANSI/ISA-67.01.01-2002PrefaceThis preface, as well as all footnotes and annexes, is incl
4、uded for information purposes and is not part ofANSI/ISA-67.01.01-2002.This document has been prepared as part of the service of ISAthe Instrumentation, Systems, andAutomation Societytoward a goal of uniformity in the field of instrumentation. To be of real value, thisdocument should not be static b
5、ut should be subject to periodic review. Toward this end, the Societywelcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards andPractices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709;Telephone (919) 549-8411; Fax (919) 549
6、-8288; E-mail: standardsisa.org.The ISA Standards and Practices Department is aware of the growing need for attention to the metricsystem of units in general, and the International System of Units (SI) in particular, in the preparation ofinstrumentation standards. The Department is further aware of
7、the benefits to USA users of ISAstandards of incorporating suitable references to the SI (and the metric system) in their business andprofessional dealings with other countries. Toward this end, this Department will endeavor to introduceSI-acceptable metric units in all new and revised standards, re
8、commended practices, and technicalreports to the greatest extent possible. Standard for Use of the International System of Units (SI): TheModern Metric System, published by the American Society for Testing b) containment isolation;c) reactor core cooling;d) containment or reactor heat removal;e) pre
9、vention or mitigation of a significant release of radioactive material to the environment; orf) maintaining safe shutdown conditions;or is otherwise essential to provide reasonable assurance that a nuclear power plant can be operatedwithout undue risk to the health and safety of the public.3.6 off-l
10、ine:transducers that are either connected to the process fluid via sensing lines with one or more isolationvalves or are not exposed to the process fluid.*See references and bibliography.ANSI/ISA-67.01.01-2002 - 12 -3.7 pressure boundary integrity:the capability to retain process fluid.3.8 qualified
11、:demonstrated to be acceptable for the design requirements.3.9 sensing line:piping or tubing connecting a transducer to the process.3.10 allowable stress:the stress values allowed by the applicable piping or structural design standard.4 Safety classification4.1 Code applicabilityThe reason that a tr
12、ansducer is classified as safety-related is important in determining which of the criteriain this document shall be applicable. In general, transducers are classified as safety-related for one ormore of the following reasons:a) Pressure boundary integrityb) MountingThe transducer must be mounted in
13、a manner that prevents it from affecting the performance of othersafety-related equipment, such as following a seismic event.c) Electrical connectionThe transducer must be electrically installed in a manner that prevents it from affecting theperformance of other safety-related equipment.d) FunctionT
14、he transducers signal is to be utilized in the performance of a safety-related function.If the reason that a transducer is classified as safety-related is its function, then all of the criteria of thisdocument should be considered for applicability. However, if a transducer is safety-related due to
15、one ofthe other three reasons, only certain criteria within this document need to be considered for applicability.Consider, for example, a transducer whose only safety-related function is its pressure boundary. Thosecriteria within this document relative to ensuring that the transducer maintains the
16、 pressure boundarywould be applicable to the transducer. Criteria associated with electrical connections, separation,calibration, testing, etc. may not be relevant to such a transducer. Similarly, the user of a transducerwhose only safety-related function is its electrical connection would find the
17、criteria of this standardassociated with maintaining that electrical connection to be applicable. Criteria associated with process-fluid connections, environmental considerations, accessibility, etc. may not be applicable for such atransducer.It is the responsibility of the user to determine the rea
18、sons that a transducer is classified as safety-relatedand to apply the criteria of this document that will maintain these safety-related functions.4.1.1 In-line transducersInstallations of transducers in Code piping, vessels, or equipment shall comply with the Code.- 13 - ANSI/ISA-67.01.01-2002Trans
19、ducers for nuclear safety-related applications may be installed in or connected to non-Code piping,vessels, or equipment, as necessary to obtain measurements from non-Code systems. The Code shallnot apply to these installations.4.1.2 Off-line transducersThe Code shall not apply to off-line transduce
20、rs. Sensing lines for off-line transducers shall be installed inaccordance with ANSI/ISA-67.02.01-1999.*4.1.3 Mounting structuresMounting structures that support Code equipment shall comply with the Code (subsection NF).5 Equipment mounting5.1 Mounting of in-line transducers5.1.1 Flow-through device
21、sTo facilitate replacement and periodic inspections, flow-through transducers, such as differential pressuremeters (orifice plates, flow nozzles, venturi tubes, etc.), electromagnetic flowmeters, mass flowmeters,vortex flowmeters, positive displacement flowmeters, turbine flowmeters, ultrasonic flow
22、meters, variablearea flowmeters, and certain radiation monitors should be flange-mounted to the piping, except in ASMECode Class 1 installations.The piping shall not impose unacceptable loads on the instrument. Auxiliary supports shall be provided torestrain the instrument where the mass of the inst
23、rument puts unacceptable stress on the piping.5.1.2 Flow-past devicesFlow-past devices (such as protective wells, differential pressure meters pitot tubes, insertion-typeelectromagnetic vortex, target, and turbine flowmeters) designed to be inserted into the flow path throughthe wall of the pipe or
24、vessel, shall be installed and mounted through a piping penetration specificallydesigned to accommodate the transducer.Where removal is required for service, one of the following alternatives to permanent welding of thetransducer shall be used:a) A qualified flange connectionb) For insertion shank d
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISA6701012002TRANSDUCERANDTRANSMITTERINSTALLATIONFORNUCLEARSAFETYAPPLICATIONS 安全 应用程序 长安 发射机 安装 代替 ISA6701PDF

链接地址:http://www.mydoc123.com/p-789752.html