IEST RP-CC046 1-2013 Controlled Environments (Aerospace Non-cleanroom).pdf
《IEST RP-CC046 1-2013 Controlled Environments (Aerospace Non-cleanroom).pdf》由会员分享,可在线阅读,更多相关《IEST RP-CC046 1-2013 Controlled Environments (Aerospace Non-cleanroom).pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Institute of Environmental Sciences and Technology IEST-RP-CC046.1 Contamination Control Division Recommended Practice 046.1 Controlled Environments (Aerospace, Non-cleanroom) Arlington Place One 2340 S. Arlington Heights Road, Suite 620 Arlington Heights, IL 60005-4516 Phone: (847) 981-0100 Fax: (8
2、47) 981-4130 E-mail: informationiest.org Web: www.iest.org 2 IEST 2013 All rights reserved Institute of Environmental Sciences and Technology IEST-RP-CC046.1 IEST-RP-CC046.1 Institute of Environmental Sciences and Technology IEST 2013 All rights reserved 3 This Recommended Practice is published by t
3、he Institute of Environmental Sciences and Technology to advance the technical and engineering sciences. Use of this document is entirely voluntary, and determination of its applicability and suitability for any particular use is solely the responsibility of the user. Use of this Recommended Practic
4、e does not imply any warranty or endorsement by IEST. This Recommended Practice was prepared by and is under the jurisdiction of Working Group CC046 of the IEST Contamination Control Division. Copyright 2013 by the Institute of Environmental Sciences and Technology First printing, April 2013 ISBN 97
5、8-1-937280-07-9 PROPOSAL FOR IMPROVEMENT: The Working Groups of the Institute of Environmental Sciences and Tech-nology are continually working on improvements to their Recommended Practices and Reference Documents. Sug-gestions from users of these documents are welcome. If you have a suggestion reg
6、arding this document, please use the online Proposal for Improvement form found on the IEST website at www.iest.org. Institute of Environmental Sciences and Technology Arlington Place One 2340 S. Arlington Heights Road, Suite 620 Arlington Heights, IL 60005-4516 Phone: (847) 981-0100 Fax: (847) 981-
7、4130 E-mail: informationiest.org Web: www.iest.org 4 IEST 2013 All rights reserved Institute of Environmental Sciences and Technology IEST-RP-CC046.1 IEST-RP-CC046.1 Institute of Environmental Sciences and Technology IEST 2013 All rights reserved 5 Controlled Environments (Aerospace, Non-cleanroom)
8、IEST-RP-CC046.1 CONTENTS SECTION 1 SCOPE AND LIMITATIONS . 7 2 REFERENCES . 7 3 TERMS AND DEFINITIONS . 8 4 BACKGROUND AND PURPOSE 10 5 CONTAMINATION AND FOD CONTROL PROGRAM . 10 6 CLASSIFICATION OF CONTROLLED ENVIRONMENTS 10 7 FACILITIES REQUIREMENTS . 10 8 EQUIPMENT REQUIREMENTS . 11 9 PROCESS REQ
9、UIREMENTS . 12 10 OPERATION OF CONTROLLED AREAS 12 11 PRODUCT CLEANLINESS 15 12 MONITORING OF CONTROLLED AREAS AND RECORD KEEPING 15 TABLE 1 RECORD OF MAINTENANCE PROCEDURES . 13 6 IEST 2013 All rights reserved Institute of Environmental Sciences and Technology IEST-RP-CC046.1 IEST-RP-CC046.1 Instit
10、ute of Environmental Sciences and Technology IEST 2013 All rights reserved 7 Institute of Environmental Sciences and Technology Contamination Control Division Recommended Practice 046.1 Controlled Environments (Aerospace, Non-cleanroom) IEST-RP-CC046.1 1 SCOPE AND LIMITATIONS 1.1 Scope This Recommen
11、ded Practice (RP) provides non-cleanroom contamination control criteria to support successful performance of products and associated subassemblies, targeted for suppliers of aerospace products. The criteria discussed are intended to assist manufacturers in implementing production methods and process
12、 controls, including minimum facility envi-ronmental controls, not including room airborne parti-cle fallout quantification. This includes production operations from piece-part acquisition through delivery of the final product. This RP is not associated with cleanroom requirements or related documen
13、tation. 1.2 Limitations This document provides a minimum set of require-ments and controls for processes and facilities associated with the assembly, integration, and testing of high-reliability aerospace products that are not required to be produced in cleanrooms. These requirements may be tailored
14、 as appropriate for specific products and processes. However, tailoring must be approved in writing by the contracting organization before work is performed. More stringent contamination control requirements imposed by the contracting documenta-tion take precedence over this document. This document
15、does not address requirements and control features for regulated industries (e.g., phar-maceutical, food, medical). Where the requirements stated in this RP conflict with any requirement in a specification referenced in this RP, the requirements of this RP should apply. 2 REFERENCES The cited editio
16、ns of the following documents are incorporated into this RP to the extent specified here-in. Subsequent revisions of these publications do not automatically supersede the cited editions. Users should investigate the applicability of revised edi-tions of the references. 2.1 American National Standard
17、s Institute (ANSI) ANSI/ESD S.20.20-2007: Protection of Electrical and Electronic Parts, Assemblies and Equipment (Exclud-ing Electrically Initiated Explosive Devices) 2.2 American Society for Testing and Materials (ASTM) ASTM E595: Standard Test Method for Total Mass Loss and Collected Volatile Con
18、densable Materials from Outgassing in a Vacuum Environment ASTM E1548: Standard Practice for Preparation of Aerospace Contamination Control Plans 2.3 Federal and Military Documents MIL-HDBK-406: Contamination Control Technolo-gy: Cleaning Materials for Precision Pre-Cleaning and Use in Cleanrooms an
19、d Clean Work Stations MIL-HDBK-407: Contamination Control Technolo-gy: Precision Cleaning Methods and Procedures TO 00-25-203: Contamination Control of Aerospace Facilities, U.S. Air Force 8 IEST 2013 All rights reserved Institute of Environmental Sciences and Technology IEST-RP-CC046.1 2.4 Institut
20、e of Environmental Sciences and Technology (IEST) IEST-RP-CC003: Garment System Considerations for Cleanrooms and Other Controlled Environments IEST-RP-CC032: Flexible Packaging Materials for Use in Cleanrooms and Other Controlled Environments 2.5 International Organization for Standardization (ISO)
21、 ISO 14644-1: Cleanrooms and associated controlled environmentsPart 1: Classification of air cleanliness 2.6 National Aerospace FOD Prevention, Inc. NAFPI FOD Prevention Guidelines (www.nafpi.nafpiguidline.pdf) 2.7 NASA NASA-JSC-SN-C-0005, Revision D Space Shuttle: Contamination Control Requirements
22、 2.8 Sources and Addresses ANSI American National Standards Institute 25 West 43rd Street New York, New York 10036, USA Phone: 212-642-4900 Fax: 212-398-0023 E-mail: infoansi.org www.ansi.org ASTM International American Society for Testing and Materials 100 Barr Harbor Drive West Conshohocken, Penns
23、ylvania 19428-2959, USA Phone: 610-832-9585 Fax: 610-832-9555 www.astm.org Federal and Military DODSSP The Department of Defense Single Stock Point for Military Specifications, Standards and Related Publications Building 4, Section D 700 Robbins Avenue Philadelphia, Pennsylvania 19111-5098 Phone: 21
24、5 697-6257/6396 Fax: 215 697-9398 http:/www.dodssp.daps.dla.mil IEST Institute of Environmental Services and Technology Arlington Place One 2340 South Arlington Heights Road, Suite 620 Arlington Heights, Illinois 60005-4510 Phone: 847-981-0100 Fax: 847-981-4130 E-mail: informationiest.org www.iest.o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IESTRPCC04612013CONTROLLEDENVIRONMENTSAEROSPACENONCLEANROOMPDF
![提示](http://www.mydoc123.com/images/bang_tan.gif)
链接地址:http://www.mydoc123.com/p-784827.html