IESNA TM-21 ADD B-2015 Projecting Long Term Lumen Maintenance of LED Light Sources.pdf
《IESNA TM-21 ADD B-2015 Projecting Long Term Lumen Maintenance of LED Light Sources.pdf》由会员分享,可在线阅读,更多相关《IESNA TM-21 ADD B-2015 Projecting Long Term Lumen Maintenance of LED Light Sources.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 Addendum B for TM-21-1: Projecting Long Term Lumen aintenance of LED Light Sources If you, as a user of IESs TM-21-11, believe you have located an error not covered by the folowing revisions, you should e-mail your information to Pat McGillicuddy, pmcgillicuddyies.org or send a letter to Pat McGill
2、icuddy, Manager of Technology, IES,120 Wall St. 17thFloor, New York, NY 10005. Additions will be posted to this list online as they become available. This errata list was last updated October 5, 2015. This Addendum replaces specified sections in document IES TM-21-11 based on the post- publishing pr
3、actice and users inputs. This Addendum supersedes and nullifies the statements made in Addendum A for TM-21-11: Projecting Long Term Lumen Maintenance of LED Packages. 4.3 Luminous Flux Data Collection and Selection Additional measurements after the initial 1000 hours at intervals smaller than 1000
4、hours (including every 1000 hour points) are encouraged. Additional measurements beyond 6000 hours are encouraged and wil provide the basis for more accurate lumen maintenance predictions. Data collected within a 48 hour window of each “1000 hour measurement point”, e.g., from 952 hours to 1048 hour
5、s, from 1952 hours to 2048 hours, etc., are aceptable for use in product lumen maintenance projections. The 48 hour window is also applicable to other intervals smaller than 1000 hours. The exact time designation shall be used in the projection calculation. 5.2.3 Data Used for Curve-fit For data set
6、s of test duration, D, from 6000 hours up to 10000 hours, the data used for the curve- fits shall be the last 5000 hours of data. Data before the 1000 hour reading shall not be used for the curve fit. Data collected within a 48 hour window of each “1000 hour measurement point”, e.g., from 952 hours
7、to 1048 hours, from 1952 hours to 2048 hours, etc. shal be acceptable as each “1000 hour reading” and shall be used for luminous flux maintenance projection with the actual measured elapsed time value. The 48 hours window is also applicable to other intervals smaler than 1000 hours. The actual measu
8、red elapsed time values shall be used in the projection calculation. The data collection points used in the projection calculation shall be equaly dispersed in time (to within 48 hours). No two consecutive data collection intervals after the initial 1000 hours shal differ by more than 96 hours in le
9、ngth. For example, data may be used in the projection calculation which are collected every 1000 hours ( 48 hours), every 500 hours ( 48 hours) etc., but not every 1000 hours and ocasionaly at 500 hours, since this wil give excessive statistical weight to certain data points. For data sets of test d
10、uration greater than 10000 hours, the data for the last 50% of the total test duration shal be used for curve-fit. In other words, al data points betwen D/2 and D shal be used. For example, if the test duration is 13000 hours, use al data points betwen 6500 hours and 13000 hours. If there is no data
11、 point at D/2, then the next lower time point shal be included in the data fiting. For example, for 0 of 13000 hours of data taken every 1000 hours, use the data points betwen 6000 and 13000 hours. 6.0 Temperature Data Interpolation When in-situ DUT case temperature, Ts,i, is different from the temp
12、eratures used for LM-80-08 tests, the following procedures should be used to predict lumen maintenance life of the DUTs coresponding to the in-situ case temperature with the same operational condition (e.g., drive curent). 6.5 Limit for Extrapolation Extrapolation of any Lpvalue above the operating
13、temperature used in the LM-80-08 test shal not be performed. For example, if the highest LM-80-08 test temperature is 85C, an Lpat 100C shal not be extrapolated. If the actual operating temperature is below the lowest temperature that is used in the LM-80-08 test, the reported Lpvalue shal use the l
14、owest temperature in LM-80-08 test. For example, if the lowest LM-80-08 test temperature is 55C, an Lpat 45C shal use Lpat 55C. For interpolation betwen case temperatures with test durations of unequal lengths, in instances where the higher temperature has shorter testing duration, projections shal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IESNATM21ADDB2015PROJECTINGLONGTERMLUMENMAINTENANCEOFLEDLIGHTSOURCESPDF

链接地址:http://www.mydoc123.com/p-784777.html