IESNA LM-71-2014 Approved Guide for the Photometric Measurement of Tunnel Lighting Installations.pdf
《IESNA LM-71-2014 Approved Guide for the Photometric Measurement of Tunnel Lighting Installations.pdf》由会员分享,可在线阅读,更多相关《IESNA LM-71-2014 Approved Guide for the Photometric Measurement of Tunnel Lighting Installations.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、IES LM-71-14Approved Guide: Photometric Measurement of Tunnel Lighting InstallationsIES LM-71-14IES Approved Guide:Photometric Measurement ofTunnel Lighting InstallationsPrepared by:The Subcommittee onPhotometry of Outdoor LuminairesIES LM-71-14Copyright 2015 by the Illuminating Engineering Society
2、of North America.Approved by the IES Board of Directors, October 16, 2014, as a Transaction of the Illuminating Engineering Society of North America.All rights reserved. No part of this publication may be reproduced in any form, in any electronic retrieval system or otherwise, without prior written
3、permission of the IES.Published by the Illuminating Engineering Society of North America, 120 Wall Street, New York, New York 10005.IES Standards and Guides are developed through committee consensus and produced by the IES Office in New York. Careful attention is given to style and accuracy. If any
4、errors are noted in this document, please forward them to Rita Harrold, Director of Technology, at the above address for verification and correction. The IES welcomes and urges feedback and comments. ISBN # 978-0-87995-307-2Printed in the United States of America.DISCLAIMERIES publications are devel
5、oped through the consensus standards development process approved by the American National Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on lighting recommendations. While the IES administers the process and establishes
6、 policies and procedures to promote fairness in the development of consensus, it makes no guaranty or warranty as to the accuracy or completeness of any information published herein. The IES disclaims liability for any injury to persons or property or other damages of any nature whatsoever, whether
7、special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on this documentIn issuing and making this document available, the IES is not undertaking to render professional or other services for or on behalf of any person or entity. No
8、r is the IES undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circums
9、tances.The IES has no power, nor does it undertake, to police or enforce compliance with the contents of this document. Nor does the IES list, certify, test or inspect products, designs, or installations for compliance with this document. Any certification or statement of compliance with the require
10、ments of this document shall not be attributable to the IES and is solely the responsibility of the certifier or maker of the statement.IES LM-71-14Prepared by the Subcommittee on Photometry of Outdoor Luminaires of the IES Testing Procedures CommitteeGary Steinberg, Sub-ChairC. Cameron Miller, Liai
11、sonIES Testing Procedures CommitteeC. Cameron Miller, ChairB. Kuebler, Vice ChairD. Ellis, SecretaryK. Broughton*D. Chan*C. GalberthM. GratherR. Heinisch*R. HoranB. Hou*D. Husby*H. Kashani*T. Kawabata*R. KelleyT. Y. Koo*L. Leetzow*J. Leland*E. Morel*D. Nava*W. NewlandM. Piscitelli*J. Schutz*R. Speck
12、*L. Stafford*T. Uchida*M.-A. Vachon*C. AndersenL. Ayers*A. Baker*P. Behnke*R. BergerR. Bergin*R. BergmanJ. C.Blacker*C. Bloomfield*E. BretschneiderK. Broughton*E. Carter*D. Chan*P.-T. Chou*G. Connelly*J. Dakin*R. Daubach*L. Davis*J. Demirjian*P. Elizondo*D. Ellis*P. Franck*M. GratherY. Guan*K. Harag
13、uchi*R. Heinisch*K. Hemmi*T. Henning*T. Hernandez*R. Higley*R. Horan*J. HospodarskyS. Hua*J. HulettP-C. HungD. Husby*A. JacksonD. Jenkins*J. JiaoD. Karambelas*H. Kashani*T. Kawabata*R. Kelley*T. Y. Koo*M. KotrebaiJ. Lawton*J. Lee*L. Leetzow*J. Leland*K. Lerbs*R. Levin*I. Lewin*R. Li*K. Liepmann*S. L
14、ongoR. Low*M.-H. Lu*J. MarellaP. McCarthyG. McKeeF.-X. Morin*M. Nadal*D. Nava*B. Neale*Y. Ohno*J. Pan*D. Park*N. Peimanovic*E. Perkins*M. Piscitelli*G. Plank*E. RadkovD. Randolph*C. Richards*E. Richman*K. Rong*M. SapcoeJ. SchutzA. Serres*A. SmithR. Speck*L. Stafford*G. SteinbergR. TuttleT. Uchida*K.
15、 Wagner*J. Walker*H. Waugh*D. Weiss*J. Welch*K. Wilcox*B. Willcock*V. Wu*J. YonR. Young*J. Zhang* Advisory* Honorary MemberIES LM-71-14IES LM-71-14Please refer to the IES Bookstore after you have purchased this IES Standard, for possible Errata, Addenda, and Clarifications, www.ies.org/bookstore.Con
16、tentsIntroduction.11.0 Scope .12.0 Normative References .13.0 Conditions of Test .13.1 General13.2 New Installations .13.3 Existing Installations 13.4 Electrical Conditions 13.5 Extraneous Light .24.0 Measurement Equipment .24.1 General24.2 Photometric Instruments .24.2.1 Luminance Meters24.2.2 Illu
17、minance Meters .24.3 Electrical Instruments .25.0 Test Procedures.35.1 Measurement Locations35.1.1 Straight Tunnel Roadway 35.1.2 Curved Tunnel Roadway.35.1.3 Wall .45.2 Photometric Measurements.45.2.1 Illuminance Tunnel Roadway and Wall 45.2.2. Road Surface Measurements Luminance 45.2.2.1 Measureme
18、nt Procedure45.2.2.2 Meter Position .46.0 Test Report .5Annex A Alternative Measurement Methods 6IES LM-71-141IES LM-71-14INTRODUCTIONThis approved Lighting Measurement (LM) guide is an update of IES LM-71-2001. The guide has been updated to complement the requirements of ANSI/IES RP-22-2011, Americ
19、an National Standard Practice for Tunnel Lighting. Included in this guide are specific luminance and illuminance measure-ment methods applied to tunnels and the location of test points for these measurements. This guide was reviewed by both the IES Testing Procedures Committee and the Tunnel Lightin
20、g Subcommittee of the IES Roadway Lighting Committee.1.0 SCOPEThis LM guide defines adequate and uniform proce-dures for measuring and reporting the photometric characteristics of tunnel lighting installations. The measurement of those factors that determine the performance of tunnel lighting instal
21、lations are spe-cifically related to ANSI/IES RP-22-11.2.0 NORMATIVE REFERENCESIES Roadway Lighting Committee, American National Standard Institute Practice for Tunnel Lighting, ANSI/IES RP-22-2011, New York: Illuminating Engineering Society of North America, 2011.IES Testing Procedures Committee, I
22、ES Guide to Lamp Seasoning, IES LM-54-2012, New York: Illuminating Engineering Society of North America, 2012.3.0 CONDITIONS OF TEST3.1 GeneralThe results of field photometry are subject to greater variability than laboratory measurements because of diverse test environments. For this reason all exi
23、sting conditions at the time of the test, such as supply voltage, lamp wattage, lamp operating posi-tion, atmospheric conditions, mounting height, tilt, or any other factors that might affect the results shall be recorded.3.2 New InstallationsIt shall be ascertained that luminaires are clean and tha
24、t the lamps are new and seasoned in accordance with IES LM-54-12, IES Guide to Lamp Seasoning.3.3 Existing InstallationsWhen the tests are used to check lighting system per-formance after in-service depreciation, the conditions of lamps, luminaires, and tunnel surfaces shall be recorded. If performa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IESNALM712014APPROVEDGUIDEFORTHEPHOTOMETRICMEASUREMENTOFTUNNELLIGHTINGINSTALLATIONSPDF

链接地址:http://www.mydoc123.com/p-784721.html