IESNA LM-61-2006 Identifying Operating Factors Influencing Measured Vs Predicted Performance for Installed Outdoor High Intensity Discharge (HID) Luminaires.pdf
《IESNA LM-61-2006 Identifying Operating Factors Influencing Measured Vs Predicted Performance for Installed Outdoor High Intensity Discharge (HID) Luminaires.pdf》由会员分享,可在线阅读,更多相关《IESNA LM-61-2006 Identifying Operating Factors Influencing Measured Vs Predicted Performance for Installed Outdoor High Intensity Discharge (HID) Luminaires.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、IESNA LM-61-06IESNA Approved GuideforIdentifying OperatingFactors InfluencingMeasured Vs.Predicted Performance forInstalled OutdoorHigh IntensityDischarge (HID)LuminairesIESThe LIGHTING AUTHORITYIESNA LM-61-06IESNA Approved Guide for Identifying Operating Factors Influencing Measured Vs.Predicted Pe
2、rformance for Installed Outdoor HighIntensity Discharge (HID) LuminairesPublication of this Committee Report has been approved by the IESNA. Suggestions forrevisions should be directed to the IESNA. Prepared by:The Subcommittee on Photometry of Outdoor Luminaires of the IESNA Testing Procedures Comm
3、itteeIESNA LM-61-06Copyright 2006 by the Illuminating Engineering Society of North America.Approved by the IESNA Board of Directors, January 7, 2006, as a Transaction of the Illuminating EngineeringSociety of North America.All rights reserved. No part of this publication may be reproduced in any for
4、m, in any electronic retrieval systemor otherwise, without prior written permission of the IESNA.Published by the Illuminating Engineering Society of North America, 120 Wall Street, New York, New York 10005.IESNA Standards and Guides are developed through committee consensus and produced by the IESN
5、A Officein New York. Careful attention is given to style and accuracy. If any errors are noted in this document, please for-ward them to Rita Harrold, Director Educational and Technical Development, at the above address for verificationand correction. The IESNA welcomes and urges feedback and commen
6、ts. ISBN # 0-87995-212-1978-0-87995-212-9Printed in the United States of America.DISCLAIMERIESNA publications are developed through the consensus standards development process approved by theAmerican National Standards Institute. This process brings together volunteers representing varied view-point
7、s and interests to achieve consensus on lighting recommendations. While the IESNA administers theprocess and establishes policies and procedures to promote fairness in the development of consensus, itmakes no guaranty or warranty as to the accuracy or completeness of any information published herein
8、. The IESNA disclaims liability for any injury to persons or property or other damages of any nature whatso-ever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the pub-lication, use of, or reliance on this documentIn issuing and making this document
9、available, the IESNA is not undertaking to render professional or otherservices for or on behalf of any person or entity. Nor is the IESNA undertaking to perform any duty owedby any person or entity to someone else. Anyone using this document should rely on his or her own inde-pendent judgment or, a
10、s appropriate, seek the advice of a competent professional in determining the exer-cise of reasonable care in any given circumstances.The IESNA has no power, nor does it undertake, to police or enforce compliance with the contents of thisdocument. Nor does the IESNA list, certify, test or inspect pr
11、oducts, designs, or installations for compliancewith this document. Any certification or statement of compliance with the requirements of this document shallnot be attributable to the IESNA and is solely the responsibility of the certifier or maker of the statement.IESNA LM-61-06Prepared by the Subc
12、ommittee on Photometry of Outdoor Luminaires of the IESNA TestingProcedures CommitteePhotometry of Outdoor Luminaires SubcommitteeGary A. Steinberg, ChairCarl K. AndersenJohn B. ArensRussell C. Dahl*Richard V. Heinisch* Robert E. HoranDonald E. Husby*Lorence E. Leetzow*Samuel W. McKnight* Waneta A.
13、NewlandCarla A. OoyenRobert C. Speck*Lloyd Stafford*Lane Swainston*IESNA Testing Procedures CommitteeCarla A. Ooyen, Chair 2003-05Michael Grather, Chair 2005 -Carl K. AndersenJohn B. Arens Lawrence M. AyersWilliam E. BeakesRobert C. BergerRandall P. BerginRolf S. BergmanRandall Blanchette James R. C
14、yreRussell C. Dahl* Ronald O. DaubachKevin J. Dowling*David EllisDavid B. Goodwin*Richard V. Heinisch*Robert E. HoranDonald E. Husby*Michael A. Kalkas*Demetrios Karambelas*Mihaly KotrebaiJohn Lawton*Lorence E. Leetzow*Kelly C. Lerbs*Robert E. Levin*Ian LewinRobert Low*Joseph P. MarellaGreg McKeeSamu
15、el W. McKnight*Douglas C. Mertz*C. Cameron MillerBruce Mosher*Waneta A. NewlandYoshihiro Ohno*David W. Parkansky*Eli M. Puszkar*David N. RandolphDavid RectorDonald C. Smith*Robert C. Speck*Lloyd Stafford*Gary A. SteinbergNick Stuffer*Theodor G. Yahraus*John X. Zhang* Advisory Members* HonoraryCONTEN
16、TSForeword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1l.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17、. . . . . . . . . . . . .12.0 Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.1 Power Supply and Ballast Variations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18、. . . . . . . . . . . . . .12.1.1 Power Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.1.2 Distribution System Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22.1
19、.3 Wave Shape of Voltage and Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22.1.4 Ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22.1.4.1 Design Variations .
20、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22.1.4.2 Core and Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22.1.4.3 Capacitor . . . . . . . . . .
21、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22.1.4.4 Starting Aids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.1.4.5 Wave Shape of Voltage and/or Curr
22、ent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.1.4.6 Ballast Component Temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.2 Lamp Variations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.2.1 Light Output of the Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.2.1.1 Manufacturing Variations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24、 . . . . . . . . . . . . . . . . . . . . . . .32.2.1.2 Light Output at Field Installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42.2.2 Arc Tube Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IESNALM612006IDENTIFYINGOPERATINGFACTORSINFLUENCINGMEASUREDVSPREDICTEDPERFORMANCEFORINSTALLEDOUTDOORHIGHINTENSITYDISCHARGEHIDLUMINAIRESPDF

链接地址:http://www.mydoc123.com/p-784715.html