GMW GMW16633-2011 Exhaust Gas Heat Recovery Unit Validation Tests Issue 1 English《废气热回收装置的验证试验 第1次出版(英文版本)》.pdf
《GMW GMW16633-2011 Exhaust Gas Heat Recovery Unit Validation Tests Issue 1 English《废气热回收装置的验证试验 第1次出版(英文版本)》.pdf》由会员分享,可在线阅读,更多相关《GMW GMW16633-2011 Exhaust Gas Heat Recovery Unit Validation Tests Issue 1 English《废气热回收装置的验证试验 第1次出版(英文版本)》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 WORLDWIDE ENGINEERING STANDARDS General Specification GMW16633 Exhaust Gas Heat Recovery Unit Validation Tests Copyright 2011 General Motors Company All Rights Reserved August 2011 Originating Department: GME Specification Center Page 1 of 9 1 Introduction Note: Nothing in this standard supercedes
2、applicable laws and regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Scope. The intent of this standard is to define a set of validation tests for an Exhaust Gas Heat Recovery Unit (EGHR) which are not covered by o
3、ther existing GM Test Procedures. This standard includes EGHR which are located directly at a close coupled catalytic converter (CC-EGHR) and EGHR which are installed in an under floor position (UF-EGHR). It is applicable for all Exhaust Gas Heat Recovery Systems for cars and light commercial vehicl
4、es. 1.2 Mission/Theme. This standard establishes the minimum requirements for the validation of an EGHR. All requirements of this specification must be met in order to demonstrate design validation (DV) and product validation (PV). It does not cover all necessary functional or validation tests which
5、 are described in the corresponding SSTS for the EGHR. For a complete validation of the EGHR refer to the “Validation Cross Reference Index for EGHR” as described in the SSTS “Exhaust Gas Heat Recovery Unit” (Appendix C3 of the Exhaust SSTS). 1.3 Classification. Not applicable. 2 References Note: On
6、ly the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. None 2.2 GM Standards/Specifications. GM6277M GMW3059 GMW15261 2.3 Additional References. EGHR-SSTS, Appendix C3 of Exhaust SSTS 3 Test Preparation and Evaluation 3.1 Resources. 3.1.1 C
7、alibration. The test facilities and equipment shall be in good working order and shall have a valid calibration label. 3.1.2 Alternatives. Alternative test facilities and equipment may also be used. However, all measuring variables as specified in this standard shall be determined correctly with res
8、pect to their physical definition. Usage of alternative facilities needs the prior approval by the General Motors Design Release Engineer (DRE) and the General Motors Validation Engineer. 3.1.3 Facilities. 3.1.3.1 Burst pressure test bench with a maximum pressure of 3 MPa. 3.1.3.2 Climate chamber wh
9、ich can be cooled down to -30 C capable to contain the EGHR. 3.1.4 Equipment. 3.1.4.1 Instrumentation and recording equipment for the documentation of all test parameters. Details can be found in the appropriate test description. Copyright General Motors Company Provided by IHS under license with Ge
10、neral Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW16633 Copyright 2011 General Motors Company All Rights Reserved August 2011 Page 2 of 9 3.1.4.2 Controllable hot gas source (fuel burner) with a maximum mass f
11、low of 540 kg/h at +1000 C Note: The above required values are worst case values. They can be lowered based on the requirements given by the program specific EGHR SSTS. 3.1.4.3 Controllable coolant loop with a coolant flow of 25 l/minute at +100 C. 3.1.4.4 Air blower capable to deliver fresh air at
12、room temperature (RT ) (+23 5) C) at the same mass flow like the hot gas source. 3.1.4.5 A control device capable to switch the actuator automatically between “Non-Recovery Mode” and “Recovery Mode”. A full actuator cycle (switching from “Non-Recovery Mode” to “Recovery Mode” and back to “Non-Recove
13、ry Mode”) shall be completed within a maximal time of 3 s. Note: Only necessary for an EGHR with non-thermostatic actuator. 3.1.4.6 Electromagnetic or hydraulic shaker with a minimum acceleration of 8 G (78.5 m/s) and a minimum frequency of 200 Hz. 3.1.5 Test Vehicle/Test Piece. EGHR test samples eq
14、uipped with interfaces (exhaust pipe flanges, coolant connectors) according to the release drawing. 3.1.6 Test Time. Calendar time: (60 to 220) days (depending on actuator technology) Test hours: (1100 to 5000) h (depending on actuator technology) Coordination hours: 30 h 3.1.7 Test Required Informa
15、tion. Not applicable. 3.1.8 Personnel/Skills. Not applicable. 3.2 Preparation. As described in the appropriate test description. 3.3 Conditions. 3.3.1 Environmental Conditions. Unless otherwise required by the appropriate test, all tests shall be performed at (+23 5) C, together with the exhaust sys
16、tems connectors and the fluid loop connectors. The connectors shall be assembled with the nominal torque given by the release drawing. 3.3.2 Test Conditions. Deviations from the requirements of this standard shall have been agreed upon. Such requirements shall be specified on component drawings, tes
17、t certificates, reports, etc. 3.4 Instructions. Not applicable. 3.5 Data. Not applicable. 3.6 Safety. This standard may involve hazardous materials, operations, and equipment. This standard does not propose to address all the safety problems associated with its use. It is the responsibility of the u
18、ser of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 3.7 Documentation. Samples of components or material released to this standard shall be tested for conformity with the requirements of this standard and a
19、pproved by the responsible GM Department prior to the start of delivery of production level components or materials. Any change to the component or material, e.g., design, function, properties, manufacturing process and/or location of manufacture requires a new release of the product. It is the sole
20、 responsibility of the supplier to provide the customer, unsolicited, with documentation of any change or modification to the product/process, and to apply for a new release. If not otherwise agreed to, the entire verification test shall be repeated and documented by the supplier prior to start of d
21、elivery of the modified or changed product. In some cases, a shorter test can be agreed to between the responsible GM department and the supplier. 3.7.1 Test Results. The test results shall be compiled to a test report which contains the following sections: 3.7.1.1 Test Piece Description. Part name
22、and/or number, development state, date of manufacture, drawing number and drawing state. 3.7.1.2 Summary of Test results. Documentation of individual test results, target values, rating of test results (OK, NOK) and deviations from the test procedure, if necessary. Test incidents shall be documented
23、 additionally with pictures. Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW16633 Copyright 2011 General Motors Company All Rights Reser
24、ved August 2011 Page 3 of 9 3.7.1.3 Test Description. Description and pictures of test setup. Calibration of test equipment. 4 Requirements and Procedure 4.1 Maximum Exhaust Gas Pressure Test. The EGHR shall withstand high pressure on the exhaust gas side for short term (in case of misfiring or simi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW166332011EXHAUSTGASHEATRECOVERYUNITVALIDATIONTESTSISSUE1ENGLISH 废气 回收 装置 验证 试验 出版 英文 版本 PDF

链接地址:http://www.mydoc123.com/p-757819.html