GMW GMW14390-2011 Durability Test of Exhaust Pipe Connections Issue 2 English《排气管连接的耐久性试验 第2次出版(英文版本)》.pdf
《GMW GMW14390-2011 Durability Test of Exhaust Pipe Connections Issue 2 English《排气管连接的耐久性试验 第2次出版(英文版本)》.pdf》由会员分享,可在线阅读,更多相关《GMW GMW14390-2011 Durability Test of Exhaust Pipe Connections Issue 2 English《排气管连接的耐久性试验 第2次出版(英文版本)》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW14390 Durability Test of Exhaust Pipe Connections Copyright 2011 General Motors Company All Rights Reserved July 2011 Originating Department: GME Specification Center Page 1 of 5 1 Scope Note: Nothing in this standard supercedes applicable laws and
2、regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Purpose. Determination of the dynamic strength in a bench test. 1.2 Foreword. Not applicable. 1.3 Applicability. For all pipe connections of mufflers, catalytic conv
3、erters, diesel particulate filters and connecting flanges. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. None 2.2 GM Standards/Specifications. None 2.3 Additional References. CTS/part drawing 3 Resources 3.1 Fa
4、cilities. Force controlled test bench with closed control loop, travel sensor and cycle counter. The test device shall be suitable for dynamic forces of (100 to 2000) N with regard to a test frequency range of (10 to 20) Hz (sine). The test facility shall have a valid ISO certificate which is noted
5、in a test report. 3.2 Equipment. 3.2.1 Peak Value Recorder. Peak Value Recorder to automatically record the oscillation amplitude, with automatic shut-off for the testing machine when the oscillation amplitude exceeds the adjusted limiting values. 3.2.2 Attachment of Test Piece. 3.2.2.1 Attachment o
6、f Flange. The flange shall be attached on a rigid fixing device without gasket with regard to bolted joint specified by drawing. The connection shall be such that pipe connection/welded joint of the flange is not impaired. The force application shall ensure the malleability of the pipe. The force sh
7、all be located according to paragraph 3.2.2.2. 3.2.2.2 Attachment of Mufflers, Catalytic Converters and Diesel Particulate Filters. The test piece shall be mounted such that the pipe connection is not impaired (see Figure 1). The force application shall ensure the malleability of the pipe. A link wi
8、th a U-joint at the ends shall be installed between load cell and force application. Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW1439
9、0 Copyright 2011 General Motors Company All Rights Reserved July 2011 Page 2 of 5 Figure 1: Photo of Muffler 1 Base plates 2 Clamping claws 3 Force application 4 Universal clamping system 5 Force gauge 5 kN maximum S = Muffler clamping length S = 245 mm. A = Distance between bottom of pot and clampi
10、ng claw A = 65 mm. X = Lever arm measured from center of pipe welding joint to center of force application; X = 150 mm. Ma = The tightening torque of clamping claw shall be selected in such a way that the pot casing is neither deformed nor impaired. L = The length of force application measured from
11、load cell connection to the center of pipe connection shall be 150 mm minimum. 3.3 Test Vehicle/Test Piece. At least 5 new production parts shall be tested for each pipe connection / type. The parts shall be produced as specified by assembly drawing. The pipe length shall be 200 mm, however 300 mm m
12、easured from pipe welding joint. Pipe connections shall be extended with a pipe as specified by drawing, if necessary. To the correct lug-in depth, tightening torque of the production clip shall be ensured, in order to guarantee a defined rigidity at the connection point. Conditioning of parts, if a
13、pplicable, shall be taken from the CTS/part drawing. 3.4 Test Time. Not applicable. 3.5 Test Required Information. Not applicable. Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-
14、,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW14390 Copyright 2011 General Motors Company All Rights Reserved July 2011 Page 3 of 5 3.6 Personnel/Skills. Not applicable. 4 Procedure 4.1 Preparation. 4.1.1 Test Setup. The test setup shall be performed using the direction of force application determined f
15、rom the strain collectives for the respective vehicle type and motorization, which is indicated in the CTS/drawing specification. 4.2 Conditions. 4.2.1 Environmental Conditions. The test shall be performed at (+23 5) C ambient room temperature. 4.2.2 Test Conditions. Deviations from the requirements
16、 of this standard shall have been agreed upon. Such requirements shall be specified on component drawings, test certificates, reports, etc. 4.3 Instructions. The strength test shall be performed as a single-step test. 4.3.1 Test torque, test frequency, cycles of failure (N 90%), and maximum permissi
17、ble dispersion (N 90% / N 10%) can be taken from the CTS/drawing specification. Mb = FP X in Nm = Test torque FP = Test force at test piece F = (FT + FP) = Test force at load cell, measured from load cell connection to pipe connection. At the dynamic test it is determined by the dynamic mass flow an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW143902011DURABILITYTESTOFEXHAUSTPIPECONNECTIONSISSUE2ENGLISH 排气管 连接 耐久性 试验 出版 英文 版本 PDF

链接地址:http://www.mydoc123.com/p-757485.html