GMKOREA EDS-T-5440-2008 THE TEST PROCEDURE OF COMPONENTS FOR PASSIVE TYPE ROOF ANTENNA.pdf
《GMKOREA EDS-T-5440-2008 THE TEST PROCEDURE OF COMPONENTS FOR PASSIVE TYPE ROOF ANTENNA.pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-5440-2008 THE TEST PROCEDURE OF COMPONENTS FOR PASSIVE TYPE ROOF ANTENNA.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards THE TEST PROCEDURE OF COMPONENTS FOR PASSIVE TYPE ROOF ANTENNA Do Not Use on New Programs. Being Replaced by GMW3172 EDS-T-5440 ISSUED DATE: 2000. 05. 10 REVISED DATE: 2008. 10. 21 VERSION: 3 (Superceded) EDS-T-5440TH
2、E TEST PROCEDURE OF COMPONENTS FOR PASSIVE TYPE ROOF ANTENNA PAGE: 1/6 ISSUED DATE: 2000. 05. 10 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. T255 Program). It is Superceded for all future projects and replaced b
3、y GMW3172. 1. PURPOSE This standard is to test accurately on Passive Type Roof Antenna for all GM DAEWOO Auto & Technology Company (hereinafter referred to as the “GMDAT“) produced automobile. 2. APPLICABLE EXTEND This standard applies to Passive Type Roof Antenna (hereafter, Antenna) including rela
4、y cable test method which applies on the Company produced vehicles. 3. TERMS & DEFINITION 3.1. Passive Type Roof Antenna The official name of protrude fixed antenna, it is protruded rod type which mounted on the roof of the vehicle. It also includes coaxial trunk-line, and Connector. 4. TEST CONDITI
5、ON 4.1. Standard Test Condition If no specified, test operation must proceed at the normal temp/humidity of 235. 4.2. Quantity of the DUT If not specified, use 12 DUT (6 for environmental test, 6 for durability test) for test operation 4.3. Test instrument & Equipment 4.3.1. General Subject: The Mea
6、suring Equipment must be approved by the Governmental Authority of Calibration and the period is to be valid. 4.3.2. RCL-Meter: Measured frequency can be measure from 1 and the ratio must be 0.11 % or higher. 4.3.3. Radio Frequency Signal Generator (RF Signal Generator): Must have usable Frequency r
7、ange of 30 to 300 , and Signal generating output of +13dBm or higher with less than 0.1dB tolerance. 4.3.4. Network Analyzer: Must have usable Frequency range of 30 to 300 with Vector analyzing capable, and the tolerance rate must be lower than 1%. 4.3.5. Control equipment for Durability Test: Must
8、kept records of test operation number. During the error occurrences, it must sense and remember the test operation number. 5. TEST EDS-T-5440THE TEST PROCEDURE OF COMPONENTS FOR PASSIVE TYPE ROOF ANTENNA PAGE: 2/6 ISSUED DATE: 2000. 05. 10 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Techn
9、ology 5.1. External Shape Test 5.1.1. Unaided Eye Test When inspecting an Antenna with naked eye, check for harmful crack, crevice, or other defects that may influence the performances. 5.1.2. Measuring Test Use specific vernier calipers to confirm the DUT matches with design specs and symmetrical t
10、o its size plan. 5.2. General Performance 5.2.1. Contact Resistance Specify the Mounting base with Pole attached and DC resistance at the end of trunk-line. If not specified, it should be within the range of 10m . 5.2.2. Trunk line Earth wire Resistance Measure the DC resistance from the end of Trun
11、k line shield to Input, and specify separately for each Trunk lines length. If no specification in the plan, the resistance must be with in 35 m if trunk lines length is longer than 1500mm, and 60 m if the trunk lines length is longer than 4000mm. 5.2.3. Antenna Ground Connection Resistance Attachin
12、g condition should be based on clause 5.2.8. DC resistance between main-body of antenna and Earth-wire must be lower than 10m . 5.2.4. Parallel Equivalent Resistance Measuring condition should be based on clause 5.2.8. Set RCL-Meter measuring frequency at 1 and the measurement must be higher than 80
13、0 . 5.2.5. Insulation Resistance Measuring condition should be based on clause 7.2.8. Impress DC 500V from the Insulation Resistance tester, and the Insulation Resistance must be less than 100 . 5.2.6. Trunk Line Tensile Measure the Tensile between the Main body & connector, and Main body & Lead wir
14、e of the trunk line. Must not have problems in performance or external appearances when load 133 N, and the Tensile measurement must be done where final connector is seceded and disconnected Lead wire. 5.2.7. Connector Connection Repeat the cast off procedure for 50times on Audio, Antenna and Trunk-
15、lines. At this point, measured insertion and cast-off force should be within the range of 22N90N. From the Maximum measurements out of 12, the minimal range should be within the range of 20% 5.2.8. Mounting Angle adjustment This test is to measure the Mounting angle adjust function at the mounting b
16、ase as stated in designed plan. The angle should be decided from the supplier if not specified on the designed plan. EDS-T-5440THE TEST PROCEDURE OF COMPONENTS FOR PASSIVE TYPE ROOF ANTENNA PAGE: 3/6 ISSUED DATE: 2000. 05. 10 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology 5.2.9. E
17、lectrostatic Capacitance Mount the completely pulled out Antenna on top of the metal plate (1m for width/length). Mount the metal plate on top of the table with 1m height. Figure1. Configure the Measuring Meter as equal to Electrostatic Capacitance Measuring Meter. At this point, the Electrostatic c
18、apacitance for Antenna should be within the range of 50 pF to 90 pF when measure my the RCL-Meter with1 , and kept record separately on each relay cable and Antenna. The Electrostatic capacitance for relay-cable must be decided from the agreement between user and supplier, and it must be stated in d
19、esign plan. However if related standard is not specified, then it must satisfied the Electrostatic capacitance for each length of relay cable from table 1. Figure1. Electrostatic Capacitance Meter Table1. Electrostatic Capacitance for each Length of Relay cable Division 600X or shorter 600X 1500X 15
20、00X or longer Characteristic Impedance 50 ohmmeter 75 ohmmeter 91 ohmmeter 125 ohmmeter Electrostatic Capacitance 99 /m 69 /m 43 /m 30 /m 5.2.10. Selectivity (Q) Configure the Measuring Method as equal to 7.2.9 Measuring meter. Measuring frequency of Q-meter is1 , and the measurement must be grater
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST54402008THETESTPROCEDUREOFCOMPONENTSFORPASSIVETYPEROOFANTENNAPDF

链接地址:http://www.mydoc123.com/p-757158.html