GMKOREA EDS-T-5411-2008 THE TEST PROCEDURE OF COMPONENTS FOR EQUALIZER AMPLIFIRE.pdf
《GMKOREA EDS-T-5411-2008 THE TEST PROCEDURE OF COMPONENTS FOR EQUALIZER AMPLIFIRE.pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-5411-2008 THE TEST PROCEDURE OF COMPONENTS FOR EQUALIZER AMPLIFIRE.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards THE TEST PROCEDURE OF COMPONENTS FOR EQUALIZER AMPLIFIRE Do Not Use on New Programs. Being Replaced by GMW3172 EDS-T-5411 ISSUED DATE: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 4 (Superceded) EDS-T-5411THE TEST
2、 PROCEDURE OF COMPONENTS FOR EQUALIZER AMPLIFIRE PAGE: 1/9 ISSUED DATE: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. T255 Program). It is Superceded for all future projects and replaced by GMW3172. 1
3、. PURPOSE This standard aims at specifying the test conditions and test method of the equalizer amplifier for automobiles that are installed to the vehicles manufactured by GMDAT. 2. SCOPE This standard applies to the equalizer amplifier for automobiles. 3. TEST SAMPLE AND NO. OF SAMPLES Unless spec
4、ified otherwise, respective 6 DVP and PVP shall be provided for test. 4. TEST CONDITIONS Unless specified otherwise, test shall be conducted in the standard test conditions (+23 5K) specified in KS A006. 5. TEST EQUIPMENT 5.1. Generals Measuring instruments used for test shall basically be calibrate
5、d by the national calibration institute and within the effective calibration period. 5.2. Signal generator A sinuous frequency generator, it shall be capable of generating the frequency in the audible range of 10 Hz to 20 KHz. 5.3. Noise generator A white noise and pink noise generator, it shall be
6、capable of generating the frequency in the audible range of 20 Hz to 20 KHz. 5.4. Thermostatic chamber Capable of maintaining temperature from 60 to +125, it shall have a minimum capacity of 100 liter. It shall also be able to control relative humidity at each temperature to 95% with permissible err
7、or not exceeding +2 per temperature. 5.5. Vibration tester It shall be capable of performing test to KS R 1034 (Automobile Components Vibration test Method). EDS-T-5411THE TEST PROCEDURE OF COMPONENTS FOR EQUALIZER AMPLIFIRE PAGE: 2/9 ISSUED DATE: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 4 G
8、M DAEWOO Auto & Technology 5.6. Control device for durability test It shall be capable of automatically supply and cut-off voltage for sample operation, detect defects and record the progress time and number of cycles in durability test. 6. TEST PROCEDURES 6.1. Appearance test 6.1.1. Visual test (1)
9、 Conduct visual inspection. (2) When observed visually, the sample shall show no signs of harmful flaws, cracks, or other defects that may adversely affect the function. 6.1.2. Dimension test Specified samples based on KS B 5203 (Vernier calipers) shall be used. Samples shall meet material requireme
10、nts of the design specifications and dimensional requirements in drawings. 6.2. General performance 6.2.1. Operating voltage To operate at 9V 16V. (Conduct test separately for the accessories power cables and battery power cables.) 6.2.2. Leakage current Unless specified otherwise in drawings, the m
11、easured current shall not exceed 2 v . 6.2.3. Input resistance (1) It is measured according to the circuit in Fig 2. (2)The input resistance of the amplifier shall be 4515%. 6.2.4. Output (1) It is performed based on the rated output in the product spec according to the circuit in Fig 2. (2) Increas
12、e the input voltage (Ue1, 2) until the output reaches the peak. (3) Unless specified otherwise, it is the output with 10% THD (Total Harmonic Distortion). (4) For reference, when the amplifier with maximum output of 25W4Ch is used for the equalizer amplifier, the requirements are as follows: 1) PWR
13、1 : above 4 x 14 W (distortion 10%) 2) PWR 2 : above 4 x 10 W (distortion 7%) 6.2.5. Amplification ratio transmission range and equivalent channel (1) It is measured according to the circuit in Fig 1. (2) Set the input voltage (Ue1, 2) to 0.5V. (3) In the overall transmission range of 25Hz 20,000 Hz
14、, the amplification ratio of all 4 channel shall be 8dB1dB. EDS-T-5411THE TEST PROCEDURE OF COMPONENTS FOR EQUALIZER AMPLIFIRE PAGE: 3/9 ISSUED DATE: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology 6.2.6. Distortion (1) It is measured according to the circuit in Fig 1.
15、 (2) Set the input voltage (Ue1, 2) to 0V (short-circuit). (3) In the frequency range of 50Hz 15K Hz, the total distortion shall not exceed 0.1%. 6.2.7. Equivalent cross transmission (1) It is measured according to the circuit in Fig 1. (2) Set the input voltage (Ue1, 2) to 1.0V and (Ue1, 2) to 0.0V
16、 (short-circuit). (3) Equivalent cross transmission between the channels shall be at least 50dB. 6.2.8. Efficiency of volume control (1) Set the input voltage (Ue1, 2) to 1.0V. (2) Measured frequency shall be 100 Hz 5,000 Hz. (3) It shall be possible to create a difference of 50 dB between channels
17、using the volume control. 6.2.9. Maximum noise voltage (1) It is measured according to the circuit in Fig 1. (2) Set the input voltage (Ue1, 2) to 0.0V (short-circuit). (3) The noise voltage at all output terminals shall not exceed 0.5mV and the spectrum of the noise voltage shall appear continuousl
18、y in all components. 6.2.10. Intermediate frequency of the filter (1) It shall be indicated in the drawing or spec of the manufacturer. (2) Intermediate frequency of the filter indicated in the instrument shall have a tolerance of 20%. 6.2.11. Efficiency of frequency control (1) It is performed for
19、all intermediate frequencies with a control. (2) It shall be possible to effect increase or decrease of about 12 dB 2 dB from the intermediate frequency with the control. 6.2.12. Interference between controls (1) It is performed in two adjacent intermediate frequencies. (2) When the controls are pla
20、ced at the last positions in the same direction, the interval between the intermediate frequencies shall not exceed 6dB. Within the intermediate control range of 8dB, the frequency blending interval between two intermediate frequencies shall not exceed 2dB. 6.2.13. Maximum noise voltage (measured ac
21、cording to circuit in Fig 1.) (1) Set the input voltage (Ue1, 2) to 0.0V (short-circuit). (2) When the frequency control is manipulated arbitrarily, the maximum noise voltage shall not exceed 4mV in the entire output range. (3) The spectrum of the noise voltage shall appear continuously in all compo
22、nents. 6.3. Temperature test EDS-T-5411THE TEST PROCEDURE OF COMPONENTS FOR EQUALIZER AMPLIFIRE PAGE: 4/9 ISSUED DATE: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology 6.3.1. Temperature operating test (1) Test temperature is based on the point reaching inside the sampl
23、e, which is the same as exposure of the sample to test temperature for min. 1 hour. (2) Apply standard signals to the sample to check whether performance requirements are met. Performance shall not change from standard temperature performance by more than 20%. 1) Test temperature : -202 +702 2) Test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST54112008THETESTPROCEDUREOFCOMPONENTSFOREQUALIZERAMPLIFIREPDF

链接地址:http://www.mydoc123.com/p-757147.html