1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards LOUDSPEAKER COMPONENT TEST Do Not Use on New Programs. Being Replaced by GMW14833&14834 EDS-T-5409 ISSUED DATE: 1991. 05. 02 REVISED DATE: 2008. 10. 21 VERSION: 6 (Superceded) LOUDSPEAKER COMPONENT TEST EDS-T-5409PAGE
2、: 1/7 ISSUED DATE: 1991. 05. 02 REVISED DATE: 2008. 10. 21 VERSION: 6 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. T255 Program). It is Superceded for all future projects and replaced by GMW14833&14834. 1. PURPOSE The purpose of this standard is to m
3、ake right evaluation of loudspeakers applied to automobiles manufactured by GMDAT (GM Daewoo Auto & Technology). 2. SCOPE This standard specifies all loudspeakers applied to automobiles by GMDAT. 3. DEFINITION 3.1. Loudspeaker The loudspeaker refers to all loudspeakers of chassis type and box type f
4、or automobiles used by GMDAT, which comprise woofers, mid-range loudspeakers and tweeters and also include a combination of them for specific purpose. 3.2. Anechoic chamber (Test space) Test space shall be more than 64m3, and deviation of characteristics of sound pressure attenuation shall not be mo
5、re than 1dB at the free sound field of anechoic chamber. 3.3. Test frequency The test frequency refers to measuring frequency specified in test standards or drawings used for performance tests of loudspeakers. 4. TEST CONDITIONS 4.1. Standard atmospheric conditions for testing Unless otherwise speci
6、fied, the test shall be performed at room temperature and humidity specified in KS A 0006 (Standard Atmospheric Conditions for Testing). 5. THE NUMBER OF TEST SAMPLES Unless otherwise specified, DVP and PVP 15 test samples shall be tested. 6. MEASURING INSTRUMENTS AND APPARATUS FOR TESTING 6.1. Gene
7、ral requirement For the measuring instruments and apparatus for testing, the ones calibrated by the national calibration institute and within the period of validity shall be used in principle. LOUDSPEAKER COMPONENT TEST EDS-T-5409PAGE: 2/7 ISSUED DATE: 1991. 05. 02 REVISED DATE: 2008. 10. 21 VERSION
8、: 6 GM DAEWOO Auto & Technology 6.2. Frequency generator A sine-wave generator capable of generating audio frequency band of 10 Hz to 20 KHz. 6.3. Noise generator White and pink noise generator capable of generating audio frequency band of 20 Hz to 20 KHz. 6.4. Thermostatic container A container cap
9、able of keeping the temperature of -60 to +125 with an accuracy of +2.0 per temperature and capacity of 100 liter min. The container shall be able to adjust relative humidity up to 95% at a specific temperature. 6.5. Vibration tester A tester capable of performing the tests to KS R 1034 (Method of V
10、ibration Test for Automobile Parts). 7. TEST 7.1. Appearance test 7.1.1. Visual test (1) The appearance test shall be performed by visual inspection. (2) The presence of defects such as harmful flaws, and cracks, which affect the function of the speaker shall be inspected visually. 7.1.2. Dimensiona
11、l test (1) Test samples shall conform to the material quality to the engineering design specification and product standard shall conform to the drawing. 7.2. General performance 7.2.1. Polarity Test (1) Power supply shall be DC 45V. (2) As power is turned on with correct polarity of speaker, the vib
12、ration panel should indicate upward. 7.2.2. Impedance (1) Speaker impedance shall be measured in frequency range of 20Hz 20KHz in accordance with IEC 268-5. (2) Unless otherwise specified, the nominal impedance shall follow the drawing specification as either 4 Ohm or 8 Ohm. (3) Voltage or current u
13、pon applying rated 1W power shall be read with the measurement method recorded. (4) From measurements record nominal impedance and frequency. Here, compute the mean of all test samples and the maximum or minimum value shall be within 10% of the mean. (5) Frequency for impedance measurement should be
14、 indicated on drawing and must be at most within 10% of the nominal impedance. LOUDSPEAKER COMPONENT TEST EDS-T-5409PAGE: 3/7 ISSUED DATE: 1991. 05. 02 REVISED DATE: 2008. 10. 21 VERSION: 6 GM DAEWOO Auto & Technology 7.2.3. Fundamental resonance frequency (1) Fundamental resonance frequency should
15、be indicated on drawing and follow IEC 268-5 unless otherwise specified. (2) Minimum resonance frequency measurement shall be done as in 7.2.2 and the frequency and the impedance Q at the highest impedance in low frequency bandwidth shall be read. (3) Compute the mean of all test samples and the max
16、imum and the minimum measurements must be within 10% of the mean. (4) Measurement of loudspeaker boxes or a combination of woofer, mid-range loudspeaker and tweeter shall be made for each, and shall be indicated in drawings through consultation between supplier and purchaser. Those showing the same
17、characteristics as in drawings shall be accepted. 7.2.4. Transmission curve (1) The measurement shall be made in a silent room and the distance between the product and the microphone for measuring shall be set at 1 meter. (2) The output power of the loudspeaker shall be measured from practical resis
18、tance values of nominal impedance by the sine wave from 20Hz 20KHz at each effective power level of 1W, 5W, 10W and nominal maximum output. (3) At this time, the value measured from the microphone shall be within tolerance band. The tolerance band of loudspeaker chassis and loudspeaker box shall be
19、according to drawing. (4) Also, the valleys and ridges on drawing curve using 1/8 octave filter shall not exceed 10dB. The point at -10dB below the highest frequency point, that is, at one octave frequency point, shall be called the maximum limit frequency. 7.2.5. Sound Pressure Level Curve (1) Meas
20、urement shall be made in an anechoic chamber and the distance between the loudspeaker and the microphone for measuring shall be set at 1 meter. (2) The output power of loudspeaker shall be measured from practical resistance value of nominal impedance at effective output of 1W by pink noise of speake
21、r from minimum recycle frequency to maximum limit frequency. (3) Unless otherwise specified in drawing, the 1/6 octave mean value shall be within 902. (4) Also, variation within speaker recycle frequency range on one octave curve shall be within 2. 7.2.6. Distortion factor (1) The second and third h
22、armonic frequency for the basic frequency of transmission curve shall be measured. (2) Distortion factor is specified in drawing. Unless otherwise specified, the second and the third harmonic frequency for the basic wave of 1W, 5W and 10W transfer curve in the frequency range from 300Hz to 10KHz mus
23、t not exceed 5 percent. (3) In addition, the distortion factor shall be within 10 percent at standard maximum output. 7.2.7. Hearing Quality Test (1) This test shall be performed in Hearing Chamber. LOUDSPEAKER COMPONENT TEST EDS-T-5409PAGE: 4/7 ISSUED DATE: 1991. 05. 02 REVISED DATE: 2008. 10. 21 V
24、ERSION: 6 GM DAEWOO Auto & Technology (2) This test shall be performed using sine wave of 20Hz to 20KHz. Unless otherwise specified, test voltage shall be at power levels of 1W, 5W, 10W and 20W. (3) Here, no strange noise other than normal speaker sound shall be heard. 7.3. Temperature working test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST54092008LOUDSPEAKERCOMPONENTTESTPDF

链接地址:http://www.mydoc123.com/p-757145.html