1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards RELAY ELECTRO-MECHANIC AND ELECTRONIC Do Not Use on New Programs. Being Replaced by GMW15267 EDS-T-5218 ISSUED DATE: 1995. 08. 08 REVISED DATE: 2008. 10. 21 VERSION: 4 (Superceded) EDS-T-5218RELAY ELECTRO-MECHANIC AND
2、 ELECTRONIC PAGE: 1/13 ISSUED DATE: 1995. 08. 08 REVISED DATE: 2008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. T255 Program). It is Superceded for all future projects and replaced by GMW15267. PART 1. GENERAL REQUIREMENTS 1. PURP
3、OSE This test specification determines the requirements, the test conditions and test method for the electric and physical function - and fatigue tests of relay. In part 1 of these technical delivery conditions the general requirements, which must fulfill relay, are determined. Further requirements
4、for specific types are determined in following stated parts for these technical delivery conditions. 1.1. Part 2: Relay, electro-mechanical 1.2. Part 3: Relay, electronic 2. REMARKS Samples of components or materials released to this specification shall be tested for conformity with the requirements
5、 of this specification and approved by GMDAT Technical Center prior to commencement of delivery of bulk supplies. In the event of any Intentional deviations from the requirements of this specification, it is the sole responsibility of the supplier to inform the purchaser of all such deviations. Furt
6、hermore the supplier shall submit unsolicited samples for reapproval by GMDAT Technical Center prior to commencement of delivery of deviant bulk supplies. 3. TEST SAMPLE AND TEST VOLUME If nothing else is specified, minimum 35 piece relay(20 piece for laboratory test and 15 piece for vehicle test) w
7、ith a works test certificate according to DIN 50049-2.3 are to be delivered for the initial sampling and release test according to this specification. 4. PRETREATMENT If nothing else is specified at the individual test, the tests are performed in the delivery condition at +235K and 14V0.2V without p
8、retreatment. 5. TEST PROCESS 5.1. Test is to be performed corresponding to the test diagrams in part 2, clause 2 and part 3, clause 2. The specified sequence is to be observed at testing, because otherwise it is not secured that comparable result are obtained. EDS-T-5218RELAY ELECTRO-MECHANIC AND EL
9、ECTRONIC PAGE: 2/13 ISSUED DATE: 1995. 08. 08 REVISED DATE: 2008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology 6. TEST APPARATUS 6.1. Test apparatus corresponding to the specified test method, test spec., DIN-standards etc. 6.2. Adjustable direct voltage source 0 to 16 V, with sufficient loading ca
10、pacity(carrying capacity) for the general test and determination of function values Voltage stabilization at load change from 0% to 100%: minimum 0.1% Residual control time at load change from 0% to 100% : 1 ms Residual ripple: max.30 mV 6.3. Constant-direct voltage source with corresponding current
11、 carrying capacity for the performance of fatigue test. Voltage stabilization at load change from 0% to 100%: minimum 1% Residual ripple: max. 300 mV 6.4. Direct current meter with graded range up to 100A, permissible variation 1% 6.5. Laboratory oscillograph, frequency range DC to 4 MHz RE 1 , CE 8
12、0 %. 7.3.5. Stress at overload The relay switching contact must switch and guide the 2.5 fold rated(nominal) current through switching-on of coil current (closer) or switching off(disconnection) of the coil current(opener). After a time interval von 1 min over-current must be broken through opening
13、of switching contact. This overload test must be repeated 1 times in the time interval of 10 min. EDS-T-5218RELAY ELECTRO-MECHANIC AND ELECTRONIC PAGE: 5/13 ISSUED DATE: 1995. 08. 08 REVISED DATE: 2008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology After this test the reliable function of the relay
14、must be still given. The contact voltage decrease must be under nominal load within the tolerance given in part 2 or part 3. 7.4. Mechanical requirements 7.4.1. Mechanical stress of housing The basic plate of the relay must be free from play and must be firmly arrested in the housing. The action of
15、an extension force at the basic plate may not result whose removal from the arresting. These requirements are valid for the temperature range of -403K to + 125 2.5K. 7.4.2. Mechanical stress of flat plugs The flat plugs must be fastened embedded in the basic plate. A force of 100N 10N which acts in
16、longitudinal axis of the flat plugs may not have negative influences on whose fastening or result deformation of the flat plugs. 7.4.3. Mechanical stress of relay holder The relay holder must be so designed that it resists to the force occurring at over-plugging and disconnection of multiple plug wi
17、thout deformation. The fastening of holder on the relay housing may not be damaged. At testing of the mechanical strength according to technical delivery condition EDS-T-5235 neither function damage nor a damage of fastening elements may result. 7.4.4. Plug junction 7.4.4.1. The multiple plug attach
18、ed on cable set must be suitable for the plug arrangement of basic plate well contacting and if necessary, provided with a arresting. So far as the plug arrangement is symmetrical, a deficient over-plugging of multiple plug must be prevented by a mechanical blocking. 7.4.4.2. By a suitable material
19、combination of relay plug and cable set-sided sleeve-type terminal it must be avoided that additionally electrochemical process occur favorably by the influence of humidity at the contact point, which cause a increase of junction resistance or the destruction of plug connection cable. The requiremen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST52182008RELAYELECTROMECHANICANDELECTRONICPDF

链接地址:http://www.mydoc123.com/p-757118.html