FORD WSS-M22P6-A2-2014 CABLE PRIMARY LOW TENSION 0 15 MM WALL 100 C TO BE USED WITH FORD WSS-M99P1111-A (Shown on FORD WSS-M22P6-A1).pdf
《FORD WSS-M22P6-A2-2014 CABLE PRIMARY LOW TENSION 0 15 MM WALL 100 C TO BE USED WITH FORD WSS-M99P1111-A (Shown on FORD WSS-M22P6-A1).pdf》由会员分享,可在线阅读,更多相关《FORD WSS-M22P6-A2-2014 CABLE PRIMARY LOW TENSION 0 15 MM WALL 100 C TO BE USED WITH FORD WSS-M99P1111-A (Shown on FORD WSS-M22P6-A1).pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Material Name Specification Number Date Action Changes 2014 06 11 N Status No replacement named L. Sinclair, NA 1997 04 02 Revised Revised Table 3 Column 3 Heading R.J. Patel 1997 03 12 Activated R.J. Patel WP 3948-a Page 1 of 9 CABLE, PRIMARY LOW TENSION, 0.15 MM
2、 WALL, 85 C WSS-M22P6-A1 CABLE, PRIMARY LOW TENSION, 0.15 MM WALL, 100 C WSS-M22P6-A2 CABLE, PRIMARY LOW TENSION, 0.15 MM WALL, 125 C WSS-M22P6-A3 CABLE, PRIMARY LOW TENSION, 0.15 MM WALL, 150 C WSS-M22P6-A4 CABLE, PRIMARY LOW TENSION, 0.15 MM WALL, WSS-M22P6-A5 Ni PLATED, 175 C CABLE, PRIMARY LOW T
3、ENSION, 0.15 MM WALL, WSS-M22P6-A6 Ni PLATED, 200 C NOT TO BE USED FOR NEW DESIGN 1. SCOPE The products defined by these specifications are low tension stranded and insulated cables. The cables are similar to that described in ISO 6722, with 0.15 mm insulation thickness. This specification includes
4、different temperature ratings and different conductor types i.e. plain copper, nickel plated, and copper alloy. 2. APPLICATION These cable specifications were originally released for use at a nominal system voltage of 50 V rms or less in automotive electrical harnesses. 3. REQUIREMENTS 3.1 QUALITY S
5、YSTEM REQUIREMENTS Material suppliers and part producers must conform to Quality System Requirements, QS-9000. Material specification requirements are to be used for initial qualification of materials. A Control Plan for ongoing production verification is required. This plan must be reviewed and app
6、roved by the relevant Ford Materials activity and/or Ford Supplier Technical Assistance (STA) prior to production parts submission. Appropriate statistical tools must be used to analyze process/product data and assure consistent processing of the materials. Part producers using this material in thei
7、r products, must use Ford approved materials and must conform to a process control plan which has been approved by STA and/or the relevant Materials Activity. 3.2 INFRARED SPECTROPHOTOMETRY AND/OR THERMAL ANALYSIS ENGINEERING MATERIAL SPECIFICATION WSS-M22P6-A1/A2/A3/A4/A5/A6 WP 3948-b Page 2 of 9 F
8、ord Motor Company, at its option, may conduct infrared and/or thermal analysis of material/parts supplied to this specification. The IR spectra and thermograms established for initial approval shall constitute the reference standard and shall be kept on file at the designated material laboratory. Al
9、l samples shall produce IR spectra and thermograms that correspond to the reference standard when tested under the same conditions. 3.3 CONDITIONING AND TEST CONDITIONS All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C for not less than 24 h
10、prior to testing and tested under the same conditions unless otherwise specified. 3.4 CABLE TEMPERATURE CLASS Depending upon the service conditions, the cables shall be made to belong to one of the following six classes of temperature: Class A - 40 to + 85 C Class B - 40 to + 100 C Class C - 40 to +
11、 125 C Class D - 40 to + 150 C Class E - 40 to + 175 C Class F - 40 to + 200 C 3.5 CABLE OUTSIDE DIAMETER (ISO 6722) No single value shall be outside the acceptable range of diameter as specified in Table 2. 3.6 CONDUCTOR (ASTM B 1, ASTM B 3, ASTM B 174, ASTM E 8, ISO 6722) 3.6.1 The individual stra
12、nds of the conductor shall be soft or annealed copper per ASTM B 3. Conductors of 0.35 mm2 size and smaller may use hard copper strands per ASTM B 1 or copper alloy strands. Annealed copper strand elongation shall conform to ASTM B 174. Hard copper strand shall meet the elongation requirements of AS
13、TM B 1. Compressed, compacted, or combination stranded cores may be used. Minimum conductor strand count shall comply with Table 1 of this specification. Missing strands are not allowed. 3.6.2 The conductor diameter and electrical resistance shall be determined in accordance with ISO 6722. The Condu
14、ctor Breaking Load Test shall be conducted in accordance with ASTM E 8. The values are specified in Table 1. 3.7 INSULATION (ISO 6722) ENGINEERING MATERIAL SPECIFICATION WSS-M22P6-A1/A2/A3/A4/A5/A6 WP 3948-b Page 3 of 9 3.7.1 The color of the insulation shall be specified on engineering drawing. Bas
15、e, stripe, and band marking color codes shall correspond to Table 4. Where striping is specified, the stripe shall be a minimum of 0.3 mm wide, but not more than 15 % of the circumference of the wire. The stripe shall be of the same class of material as the insulation. Where band marking is specifie
16、d (for sizes 0.13 and 0.22 mm2), the band mark shall be 3 mm +/- 1 mm wide with a 25 mm +/- 5 mm pitch. If the insulation is dyed or painted, the Durability of Cable Marking Test must be performed on the finished product. 3.7.2 The material shall adhere closely to, but strip readily from the conduct
17、ors, leaving them free of insulation and in suitable condition for applying terminals. Water soluble stripping agents shall not be used. The insulation thickness shall be determined in accordance with ISO 6722. The insulation thickness shall comply with the values listed in Table 2. 3.8 CABLE QUALIT
18、Y (TESTS) Withstand Voltage, Thermal Overload, Winding Test at Low Temperature (mandrel sizes per Table 5), Pressure at High Temperature, and Heat Shrinkage Tests shall all be conducted in accordance with ISO 6722. Ozone Resistance Test shall be conducted in accordance with SAE J1128. Note: The foll
19、owing tests, 3.8.1, 3.8.2, 3.8.3, 3.8.4, and 3.8.5, shall be tested in accordance with ISO 6722, but with exceptions to the requirements as indicated. 3.8.1 Test for Insulation Faults (In Process Testing) The test voltage shall be: 0.13 - 1.5 mm2 2 KV 3.8.2 Short Term Heat Aging (ISO 6722) During Wi
20、thstand Voltage Test, the voltage shall be applied immediately after immersion for 1 minute. Mandrel sizes are specified in Table 5. 3.8.3 Long Term Heat Aging (For Initial Qualification Only) (ISO 6722) During Withstand Voltage Test, the voltage shall be applied immediately after immersion for 1 mi
21、nute. The test temperatures are specified in the para 3.4. Mandrel sizes are specified in Table 5. 3.8.4 Resistance to Flame Propagation (ISO 6722) ENGINEERING MATERIAL SPECIFICATION WSS-M22P6-A1/A2/A3/A4/A5/A6 WP 3948-b Page 4 of 9 Any combustion flame of insulating material shall extinguish within
22、 70 seconds. 3.8.5 Fluid Resistance (ISO 6722) The fluids and the requirements are specified in Table 6. 3.8.6 Sandpaper Abrasion Resistance (SAE J1128) The sandpaper abrasion resistance shall meet the minimum abrasion requirements in Table 3. 3.8.7 Fogging Test (For Initial Qualification Only) (IEC
23、 540, para 7 (7d) at 100 +/- 2 C) This test is required for wire size of 0.75 mm2. Note: Anti-Fogging is required for all wiring passing through the body shell luggage or passenger compartments. Wiring used exclusively in the engine compartment is excluded. 3.8.8 Durability of Cable Marking 3.8.8.1
24、Procedure Prepare three test samples of approximately 600 mm. The apparatus shall consist of two pieces of felt without dressing, having a minimum wool content of 75 %, and with a packing density of 0.171 to 0.191 g/cm3 (approximate dimensions 50 x 50 x 3 mm) and a vessel containing ISO 1817, No. 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSSM22P6A22014CABLEPRIMARYLOWTENSION015MMWALL100CTOBEUSEDWITHFORDWSSM99P1111ASHOWNONFORDWSSM22P6A1PDF

链接地址:http://www.mydoc123.com/p-752597.html