FORD WSK-M4D775-A1-2014 POLYCARBONATE (PC) MOLDING COMPOUND EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf
《FORD WSK-M4D775-A1-2014 POLYCARBONATE (PC) MOLDING COMPOUND EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf》由会员分享,可在线阅读,更多相关《FORD WSK-M4D775-A1-2014 POLYCARBONATE (PC) MOLDING COMPOUND EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions Rev 02 2014 01 16 N Status Replaced by WSS-M4D1052-A1/A2/A3 G. Eaton, NA 2006 01 31 Revised Inserted 3.0; Deleted 3.1, 3.2, 3.3, 3.9, 3.10 & 4 1994 06 23 Released C10418354 L. Rodigas Copyright 2014, Ford Global Technologies, LLC Page 1 of 7
2、POLYCARBONATE (PC), MOLDING COMPOUND, WSK-M4D775-A1 EXTERIOR POLYCARBONATE (PC), MOLDING COMPOUND, WSK-M4D775-A2 OPTICAL GRADE, EXTERIOR NOT TO BE USED FOR NEW DESIGN 1. SCOPE The materials defined by these specifications are UV-stabilized polycarbonate molding compounds. WSK-M4D775-A2 materials are
3、 additionally required to fulfill optical performances. 2. APPLICATION These specifications were released originally for materials used for “FORD“ oval badges (WSK-M4D775-A1), and lenses of front headlamps and rear lamps (WSK-M4D775-A2). 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATER
4、IALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1.1 All requirements of this specification, identified by symbol(s), shall be met with data representing 3 sigma values. 3.4 MOLDING COMPOUND (s) 3.4.1 Melt Flow
5、 Rate (ISO 1133, 300 C, 1.2 kg) 6 - 15 g/10 minutes The material shall be dried for 2 h at 125 - 130 C in a mechanical convection oven immediately preceding the test. 3.5 MOLDED TEST SPECIMEN 3.5.1 Preparation of Test Specimens Unless otherwise specified all tests shall be carried out on injection m
6、olded one-end gated test specimens. The following dimensions are required: A. 150 min x 10 x 4.0 +/- 0.2 mm (Tensile Bar, ISO 3167) B. 120 x 10 x 4.0 +/- 0.2 mm Specimens with shorter dimensions shall be cut from the center portion of the test specimen A and/or B. The specimens shall be prepared acc
7、ording to ISO 294. No annealing allowed. ENGINEERING MATERIAL SPECIFICATION WSK-M4D775-A1/A2 Copyright 2014, Ford Global Technologies, LLC Page 2 of 7 3.5.2 Density 1.18 - 1.22 g/cm3 (ISO 1183, Method A) (s) 3.5.3 Tensile Strength at Yield, min 60 MPa (ISO R 527, 150 min x 10 x 4.0 +/- 0.2 mm specim
8、en, 50 mm/minute) 3.5.3.1 Elongation at Break, min 90% (Test Method according to para 3.5.3) (s) 3.5.4 Flexural Modulus, min 2.2 GPa (ISO 178, 80 x 10 x 4.0 +/- 0.2 mm specimen, 64 mm support span) 3.5.5 Shear Modulus at 23 C (ASTM D 4065, forced constant amplitude, fixed frequency of 1 Hz +/- 15%,
9、strain level below 1%. Specimen approx. 60 x 10 x 4.0 +/- 0.2 mm cut from the center of specimen A. Specimen length between clamps 35-40 mm. Soak time at each temperature interval - 3 minutes minimum). WSK-M4D775-A1 690 - 1050 MPa WSK-M4D775-A2 650 - 990 MPa Additionally, Shear Modulus vs. Temperatu
10、re curves shall be plotted for -50 to +150 C temperature range, at 5 C minimum intervals. The plotted curves must be within tolerance range shown on page 6 (WSK-M4D775-A1) and page 7 (WSK-M4D775-A2). (s) 3.5.6 Impact Strength, Izod, min (ISO 180/1A, 80 x 10 x 4.0 +/- 0.2 mm specimen, 10 specimens fo
11、r each test) 3.5.6.1 At 23 +/- 2 C 10 kJ/m2 3.5.6.2 At -40 +/- 2 C 5 kJ/m2 3.5.6.3 At 10 +/- 2 C 7 kJ/m2 The test specimens must be conditioned for minimum of 6 h at the above specified temperature prior to impact test. Low temperature testing shall be done within the cold box. (s) 3.5.7 Heat Deflec
12、tion Temperature, min 120 C (ISO 75, 120 x 10 x 4.0 +/- 0.2 mm specimen, 0.32 +/- 0.01 mm deflection. At 1.80 MPa) All specimens dry as molded. If not tested immediately after molding, specimens must be stored in a sealed, moisture-proof container filled with silica gel. ENGINEERING MATERIAL SPECIFI
13、CATION WSK-M4D775-A1/A2 Copyright 2014, Ford Global Technologies, LLC Page 3 of 7 (s) 3.5.8 Vicat Softening Temperature, min 140 C (ISO 306, 10 x 10 x 4.0 +/- 0.2 mm specimens. Bath - silicone oil, temp. raise 50 +/- 5 C/h. Dial gage reset to 0 after addition of 5 kg weight. At 50 N load) All specim
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSKM4D775A12014POLYCARBONATEPCMOLDINGCOMPOUNDEXTERIORTOBEUSEDWITHFORDWSSM99P1111APDF

链接地址:http://www.mydoc123.com/p-750801.html