FORD WSK-M4D597-A-2010 POLYETHYLENE TEREPHTHALATE (PET) 55 % GLASS FIBRE REINFORCED MOLDING COMPOUND TO BE USED WITH FORD WSS-M99P1111-A 《55%玻璃纤维增强的聚对苯二甲酸乙二酯(PET)成型料 与标准FORD WSS.pdf
《FORD WSK-M4D597-A-2010 POLYETHYLENE TEREPHTHALATE (PET) 55 % GLASS FIBRE REINFORCED MOLDING COMPOUND TO BE USED WITH FORD WSS-M99P1111-A 《55%玻璃纤维增强的聚对苯二甲酸乙二酯(PET)成型料 与标准FORD WSS.pdf》由会员分享,可在线阅读,更多相关《FORD WSK-M4D597-A-2010 POLYETHYLENE TEREPHTHALATE (PET) 55 % GLASS FIBRE REINFORCED MOLDING COMPOUND TO BE USED WITH FORD WSS-M99P1111-A 《55%玻璃纤维增强的聚对苯二甲酸乙二酯(PET)成型料 与标准FORD WSS.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Material Name Specification Number Date Action Changes 2010 01 08 N-STATUS No replacement named J. Crist, NA 1989 05 02 B/031523 TP Revised clause 3.5.5 and page 6 P. Kuntze 1988 06 15 SM/EQ4331 TP Released P. Kuntze WP 3948-a Page 1 of 5 POLYETHYLENE TEREPHTHALAT
2、E (PET) 55 % GLASS WSK-M4D597-A FIBRE REINFORCED MOLDING COMPOUND NOT TO BE USED FOR NEW DESIGN 1. SCOPE The material defined by this specification is a 55 % glass fibre rein- forced thermoplastic polyester molding compound with a high rigidity based on polyethylene terephthalate (PET). 2. APPLICATI
3、ON This specification was released originally for material used for adjuster bolts. 3. REQUIREMENTS 3.1 STATISTICAL PROCESS Suppliers must conform to the requirements of Ford Quality System Standard Q-101. A mutually acceptable Control Plan as described therein is required for material/source approv
4、al. Appropriate statistical tools must be used to analyze process/product data so that variation in the final product is continuously reduced. 3.2 INFRARED SPECTROPHOTOMETRY AND/OR THERMAL ANALYSIS Ford Motor Company, at its option, may conduct infrared and/or thermal analysis of material/parts supp
5、lied to this specification. The IR spectra and thermogram established for initial approval shall constitute the reference standard and shall be kept on file at the designated material laboratory. All samples shall produce IR spectra and thermograms that correspond to the reference standard when test
6、ed under the same conditions. 3.3 CONDITIONING AND TEST CONDITIONS All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwis
7、e specified. 3.4 MOLDING COMPOUND 3.4.1 Filler Content 53 - 57 % (ISO 3451/2, at 750 +/- 50 C, test portion 2.5 - 3.0 g) ENGINEERING MATERIAL SPECIFICATION WSK-M4D597-A WP 3948-b Page 2 of 5 3.4.2 Melt Flow Rate (MFR) 5-11 g/10 minutes (ISO 1133/ASTM D 1238, 280 +/- 0.5 C, 5 kg) The melt flow rate (
8、MFR) shall be tested immediately after drying the material at 130 - 135 C for 4 h minimum in a mechanical convection oven. 3.5 MOLDED TEST SPECIMEN 3.5.1 Preparation of Test Specimens Unless otherwise specified all tests shall be carried out on injection molded one-end gated test specimens. The foll
9、owing dimensions are required: A. 150 x 10 x 4.0 +/- 0.2 mm (Tensile Bar, ISO 3167) B. 120 x 10 x 4.0 +/- 0.2 mm Specimens with shorter dimensions shall be cut from the center portion of the test specimen A and/or B. The specimens shall be prepared according to ISO 294. No annealing allowed. 3.5.2 D
10、ensity 1.78 - 1.82 g/cm3 (ISO R 1183, Method A/ASTM D 792, Method A1) 3.5.3 Tensile Strength at Max. Load, min 170 MPa (ISO R 527/ASTM D 638M, 150 x 10 x 4.0 +/- 0.2 mm specimen, test speed, 5 mm/minute) 3.5.4 Flexural Modulus, min 17.5 GPa (ISO 178/ASTM D 790M, Method I, Procedure A, 80 x 10 x 4.0
11、+/- 0.2 mm specimen, 64 mm support span) 3.5.5 Shear Modulus at 23 C 2.28 - 3.81 GPa (Method B/ASTM D 4065, forced constant amplitude, fixed frequency of 1 Hz +/- 15 %, strain level below 1 %. Specimen approx. 60 x 10 x 4.0 +/- 0.2 mm cut from the center of specimen A.) Additionally, a Shear Modulus
12、 vs. Temperature curve shall be plotted for -50 to + 240 C temperature range, at 5 C minimum intervals. The plotted curve must be within tolerance range shown on page 6. 3.5.6 Impact Strength, Izod (ISO 180, Method A/ASTM D 256, Method A, 63.5 x 10 x 4.0 +/- 0.2 mm specimen, 10 specimens for each te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSKM4D597A2010POLYETHYLENETEREPHTHALATEPET55GLASSFIBREREINFORCEDMOLDINGCOMPOUNDTOBEUSEDWITHFORDWSSM99P1111A55

链接地址:http://www.mydoc123.com/p-750600.html