FORD FLTM BZ 157-01-2011 DETERMINATION OF ORGANIC EMISSIONS FROM NON-METALLIC MATERIALS IN VEHICLE INTERIORS BY HEADSPACE GAS CHROMATOGRAPHY《对根据顶空气相色谱法车辆内饰中非金属材料有机废气的测定》.pdf
《FORD FLTM BZ 157-01-2011 DETERMINATION OF ORGANIC EMISSIONS FROM NON-METALLIC MATERIALS IN VEHICLE INTERIORS BY HEADSPACE GAS CHROMATOGRAPHY《对根据顶空气相色谱法车辆内饰中非金属材料有机废气的测定》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BZ 157-01-2011 DETERMINATION OF ORGANIC EMISSIONS FROM NON-METALLIC MATERIALS IN VEHICLE INTERIORS BY HEADSPACE GAS CHROMATOGRAPHY《对根据顶空气相色谱法车辆内饰中非金属材料有机废气的测定》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD FLTM BZ 157-01 Date Action Revisions Rev. 1 2011 03 11 Revised Added preferred use of GC/MSS. S.Riewer, FOE 2009 01 03 Activated S.Riewer, FOE Printed copies are uncontrolled Copyright 2011, Ford Global Technologies, LLC Page 1 of 4 DETERMINATION OF ORGANIC EMISSIONS FRO
2、M NON-METALLIC MATERIALS IN VEHICLE INTERIORS BY HEADSPACE GAS CHROMATOGRAPHY Application This test method is used to determine emissions of organic compounds (TVOC = total volatile organic compounds) which are given off from non-metallic materials in the immediate vicinity of or inside vehicle inte
3、riors. The sum of individual substances according to a gas chromatography analysis and detection with a flame ionization detector (GC/FID) or mass selective detector (GC/MS) is used as a measure of the total emission of a material. It is preferred to use GC/MS as this technology delivers more accura
4、te and more reliable results. Usage of GC/FID must be agreed by Ford Materials Engineering prior to testing. The test is performed using Head-Space technique after tempering at 120 C. The relevant sampling points, requirements and special provisions relating to the execution of the test can be found
5、 in the appropriate specifications and drawings, etc. If components are made up of a number of different materials, separate tests may be required for each individual material. Apparatus and Materials Required Acetone p.a. Butanol p.a. Gas Chromatograph for capillary column operation with Head-Space
6、 test vessel, flame ionization detector (FID) or mass selective detector (MSD) and computer/integrator. WCOT capillary column with a separation phase of 100 % polyethylene glycol (so-called wax type, e.g. DB wax, Carbowax, etc.), 0.25 mm internal diameter, 0.25 um film thickness and 30 m length. Ana
7、lytical balance with an accuracy of 0.1 mg Micro liter syringe, 5 L Beakers Graduated flasks FORD LABORATORY TEST METHOD FLTM BZ 157-01 Printed copies are uncontrolled Copyright 2011, Ford Global Technologies, LLC Page 2 of 4 Conditioning and Test Conditions Transport and storage of the samples shal
8、l take place in an aluminium-clad polyethylene bag. Sampling shall take place immediately after delivery or in a condition equivalent to that status. The dates of delivery and sampling shall be recorded. Conditioning of the sample is not normally required. One exception is natural materials (cotton,
9、 wood, leather, wool). These materials must be divided up into small pieces, dried for 24 h over calcium chloride (CaCI2) and then weighed. The sample must be taken at the stipulated point over the entire section of the component. It must be broken (without causing it to heat up) into pieces weighin
10、g between 10 mg and 25 mg. Other types of sample preparation may be indicated, if necessary, on the drawing or in the Technical Regulation (TR). This must be stated in the report of the results. The test quantity to be weighed depends on the size of the Head-Space vessel, which shall have a minimum
11、volume of 5 ml. For a 10 ml Head-Space vessel, 1,000 g 0.001 g (i.e. a maximum weighing error of 0.1 %) of the sample shall be weighed. Metal parts shall be removed before weighing. Organic substances such as paint and adhesive, etc., which are firmly attached to metal parts shall be removed by mech
12、anical means and then weighed. The sample is weighed in the Head-Space vessel (at least three Head-Space vessels per sample). The Head-Space vessel is then sealed in a gas-tight fashion with the help of a septum, with the Teflon coating on the side facing the interior of the Head-Space vessel. Metho
13、d Immediately before the measurement, the Head-Space vial is tempered to 120 + 1 C. The test period in the Head-Space is 5 h 5 min at 120 1 C, and the analysis shall take place immediately thereafter. At least three samples of each material shall be analyzed. The blind value is determined by means o
14、f the mean value from at least three measurements with empty Head-Space vessels. Metering shall take place in an identical and reproducible fashion in conjunction with all analyses of samples, blind values and calibration solutions. The column shall be burned off once a week by heating the column to
15、 its maximum operating temperature for 15 minutes. GC oven temperature Program: 3 min isothermal at 50 C Heating to 200 C at a rate of 12 C/min 4 min isothermal at 200 C Injector temperature: 200 C Detector temperature: 250 C Split ratio: approx. 1 : 20 Carrier gas: helium Mean carrier gas velocity:
16、 approx, 22 - 27 cm/s Note: The substance 2.6-di-tertiary-butyl-methylphenol (BHT) shall exhibit a retention time of less than 16 minutes. FORD LABORATORY TEST METHOD FLTM BZ 157-01 Printed copies are uncontrolled Copyright 2011, Ford Global Technologies, LLC Page 3 of 4 Calibration Calibration curv
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBZ157012011DETERMINATIONOFORGANICEMISSIONSFROMNONMETALLICMATERIALSINVEHICLEINTERIORSBYHEADSPACEGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-747710.html