FORD FLTM BZ 002-3-2001 DETERMINATION OF THE QUANTITY OF CARBON CONTAMINATION ON COLD ROLLED STEEL SURFACES.pdf
《FORD FLTM BZ 002-3-2001 DETERMINATION OF THE QUANTITY OF CARBON CONTAMINATION ON COLD ROLLED STEEL SURFACES.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BZ 002-3-2001 DETERMINATION OF THE QUANTITY OF CARBON CONTAMINATION ON COLD ROLLED STEEL SURFACES.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BZ 002-03 Date Action Revisions 2001 04 30 Revised Editorial no technical change A. Cockman 1992 08 13 Printed copies are uncontrolled Page 1 of 4 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF THE QUANTITY OF CARBON CONTAMINATION ON COLD ROLLED STEEL SU
2、RFACES Application This procedure is used to determine the quantity of carbonaceous material on steel surfaces. Apparatus Required Power Washer The power washer consists of an elongated tank with nozzles on both of the long sides. A pump recirculates the solution from the bottom of the tank through
3、the spray nozzles at the specified pressure as required. The power washer shall be constructed so as to meet the following parameters: . Nozzle pressure: 62 - 76 kPa. . Nozzle distance from test panel: 15 - 20 cm. . Number of nozzles: 12 nozzles minimum on each side, distributed for maximum coverage
4、 of the sample. The distance between adjacent nozzles should be 15 cm. . Nozzle type: Full jet number 6.5 (manufactured by Spraying Systems Co., Wheaton, IL), or equivalent. Note: A detailed print (Drawing number STD 7048) of a typical power washer unit can be obtained from Parker Division, Oxy Meta
5、l Industries Corporation, Madison Heights, MI. Rubber Gloves Any laboratory quality acid resistant rubber gloves. Filter Paper Grade 934 AH, 5.5 cm - Whatman, Inc., or equivalent. Hydrochloric Acid Reagent grade. Porcelain Crucible 5 mL capacity Coors No. 23003 - VWR Scientific; Curtin Matheson Scie
6、ntific, or equivalent. Oven Recirculating oven capable of maintaining a temperature of 260 - 280 C. FORD LABORATORY TEST METHOD BZ 002-03 Page 2 of 4 Copyright 2001, Ford Global Technologies, Inc. Carbon Determinator Leco CS 46, EC12 or equivalent. (Equipment utilizing infrared detectors is recommen
7、ded for improved accuracy.) Caution: Equipment must have adequate acid collection traps to prevent damage to the instrumentation. Consult the equipment supplier for information regarding individual pieces of apparatus. Vapor Degreaser (Method B Only) T 48E from Phillips Manufacturing Co., Detroit, M
8、I or equivalent. Smaller units suitable for the test panels are acceptable. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested
9、 under the same conditions unless otherwise specified. Procedure Method A - Power Wash Method 1. A sample 300 mm by coil width, shall be obtained from that part of the coil (with a few inside laps removed) which corresponds to the eye of the coil in anneal. Specimens shall be obtained from this samp
10、le as shown in the following illustration and evaluated for surface carbon. The sample must be free from rust, adhesives, crayon or felt pen marks, or any contaminants which may contain carbon (excluding normal protective oils). Illustration Note: Carbon contamination specimen may be taken from eith
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBZ00232001DETERMINATIONOFTHEQUANTITYOFCARBONCONTAMINATIONONCOLDROLLEDSTEELSURFACESPDF

链接地址:http://www.mydoc123.com/p-747691.html