1、 FORD LABORATORY TEST METHOD BZ 001-01 Date Action Revisions 2001 04 30 Revised Editorial no technical change A. Cockman 1992 08 13 Printed copies are uncontrolled Page 1 of 3 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF MOISTURE WITH A MOISTURE BALANCE Application This procedure
2、is used to determine moisture in materials such as sand, resins, water emulsion type paints and other similar materials. Both liquids and finely pulverized solids may be tested for moisture by this method providing the materials undergo no chemical change on drying. Apparatus Required Moisture Balan
3、ce (Drawing Attached) The moisture balance* consists of an enclosed unit containing a torsion balance and infrared lamp for drying the sample. Powerstat Transformer The proper heat output must be determined for each different material and, since heat output of the lamp is controlled by varying the v
4、oltage, a transformer is required. A Powerstat* transformer which operates from 115 V, A.C., with an output continuously variable from 0 - 135 V, A.C., is required. *Source: Central Scientific Co. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in
5、a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Raise the lamp housing and release the sample pan support. 2. Rotate the knurled wheel E until the 100 % line o
6、n the graduated scale is lined up with the line on the index G. FORD LABORATORY TEST METHOD BZ 001-01 Page 2 of 3 Copyright 2001, Ford Global Technologies, Inc. 3. Move the zero adjusting knob K up or down until the pointer H is directly in line with the line on the index. If the zero adjusting knob
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBZ001012001DETERMINATIONOFMOISTUREWITHAMOISTUREBALANCE 湿度 平衡器 测定 PDF

链接地址:http://www.mydoc123.com/p-747686.html