FORD FLTM BV 151-1-2001 COLD ADHESION TEST FOR SPRAY DEADENERS AND UNDERCOATING (Replaces FLTM EU-BV 051-01).pdf
《FORD FLTM BV 151-1-2001 COLD ADHESION TEST FOR SPRAY DEADENERS AND UNDERCOATING (Replaces FLTM EU-BV 051-01).pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BV 151-1-2001 COLD ADHESION TEST FOR SPRAY DEADENERS AND UNDERCOATING (Replaces FLTM EU-BV 051-01).pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、FORD LABORATORY TEST METHOD BV 151-01 Date Action 2001 10 31 Revised 2000 08 11 Revised 1990 05 24 COLD ADHESION TEST FOR SPRAY DEADENERS AND UNDERCOATING Revisions Editorial - no technical change Editorial - no technical change A. Cockman A. Cockman Application This procedure is used to determine t
2、he adhesion properties of spray deadeners and undercoating materials when subjected to impact at low temperature. Apparatus Required Laboratory Forced Air Circulation Oven Capable of maintaining temperatures up to 250 +/- 2 O C. Cold Box Capable of maintaining a temperature of - 40 +/- 2 OC. accommo
3、date the fixture during the slamming test. The box must be large enough to Balance Accuracy +/- 0.5 g - maximum permitted load 3 kg. Impact Test Fixture See Sketches 2 and 3. The test fixture consists of an angle iron frame (Part 1) with a pivoting clamping fixture (Part 2) and an adjustable counter
4、 weight (Part 3) for balancing the various specimen weights. The load (Part 5) attached to the lever (Part 4) results in an impact force when hitting the frame (Part 1). The rung (Part 6) limits the highest position of the lever. Load A = 1 .O kg Load B = 2.5 kg Materials Required Test Panels Steel
5、body Skin Panels. Preparation as in Attachment 1. Dimensions - 300 x 300 x 1.5 +/- 0.10 mm Load A. (1 .O kg) Dimensions - 300 x 300 x 1.5 +/- 0.10 mm Load B. (2.5 kg) Surface Finish 0.8 - 1.9 micrometre C.L.A. Copynght02001, Ford Global Technologies, Inc FORD LABORATORY TEST METHOD BV 151-01 Conditi
6、oning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 OC and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure (3 specimens requ
7、ired if not otherwise specified) 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 o. 11. The closed container of deadener or undercoating shall be conditioned for 24 h minimum at 23 +/- 2 OC prior to application. Determine the weight (W ) of the test panel, prepared in accordance with 1 Attachment 1, and mask off the t
8、op 20 mm of each panel where it fits into the clamping fixture. Spray the panel evenly with the test material to a wet film thickness in accordance with Attachment 1 or as specified by the applicable Engineering Material Specification. After an open time of 15 minutes at 23 +/- 2 OC, bake the panels
9、 in the oven, with forced air circulation, in accordance with Attachment 1 or as specified by the applicable Engineering Material Specification. Cool to 23 +/- 2 OC, remove masking tape, hold specimen at this temperature for 2 h and determine total weight of specimen (w). Insert specimen in the clam
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBV15112001COLDADHESIONTESTFORSPRAYDEADENERSANDUNDERCOATINGREPLACESFLTMEUBV05101PDF

链接地址:http://www.mydoc123.com/p-747657.html