1、 FORD LABORATORY TEST METHOD BO 024-01 Date Action Revisions 2001 03 27 Revised Editorial no technical change A. Cockman 1992 07 27 Printed copies are uncontrolled Page 1 of 6 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF MOISTURE CONTENT OF NYLON MOISTURE METER METHOD Application
2、This procedure describes a method for determining the moisture content of nylon resins having moisture contents in the range of 0.04 to 2.5 %. This method is applicable to nylon molding powders in the form of 1/8 inch cubes and to fabricated nylon articles from which chips approximately this same si
3、ze may be cut. This procedure, which depends on the volatilization of moisture, should be used only where it has been determined that the presence of plasticizers, fillers, lubricants or other materials added to the base nylon will not interfere with the determination. Unless test data indicates tha
4、t these added materials do not interfere with the procedure, it is recommended that moisture determinations with this method be restricted to Type 6 nylons only. Equipment Required Moisture Meter - Complete Unit (See Figure 1) Source: Manufacturers Engineering & Equipment Co. Hatboro, PA or (a) A fo
5、ur-well heater block with a control for maintaining temperature of 200 +/- 2 C and 240 +/- 2 C. (b) Four 50 cc “Luer-Lok“* type hypodermic syringes, calibrated in millimeters, selected for sliding fits at operating temperatures with outside diameters corresponding to the well openings in the heater
6、block. *Trademark of Becton, Dickinson & Co. (c) “Luer-Lok“ type closure for each syringe. (d) “Luer-Lok“ type connector with a 6 inch length of tubing. FORD LABORATORY TEST METHOD BO 024-01 Page 2 of 6 Copyright 2001, Ford Global Technologies, Inc. (e) Quantity of Dow Corning 200 silicone oil, 20 c
7、entipoise or equivalent. Prior to the moisture determination and with each new shipment of silicone oil, it will be necessary to run a blank since the silicone oil may contain volatiles. (f) Thermometer covering the 200 - 240 C range. (g) Carrying case. (h) Analytical balance. (i) Metal tongs. (j) C
8、otton gloves. (k) Rack for storing hot syringes. (l) Brush for cleaning the cylinders. (m) Lintless cloth. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 2
9、4 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Turn heater block on and temperature to reach equilibrium at 240 +/- 2 C. 2. Carefully clean the syringe cylinder and piston with a lintless cloth to remove all lint or dirt particles. 3. If sample is
10、from a molded part, cut pieces approximately the size and shape of 1/8 inch cubes. 4. Weigh out sample on balance (a) 10 +/- 0.2 g where moisture content is suspected of being in the .05 - .4 % range. (b) 1 +/- .05 g where moisture content is suspected of being in the 0.4 -2.5 % range. Note: Weigh o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBO024012001DETERMINATIONOFMOISTURECONTENTOFNYLONMOISTUREMETERMETHOD 尼龙 水分 含量 测定 湿度计 PDF

链接地址:http://www.mydoc123.com/p-747322.html