FORD FLTM BL 001-1-2001 CORROSION INHIBITION TEST FOR ETHYLENE GLYCOL ANTIFREEZE.pdf
《FORD FLTM BL 001-1-2001 CORROSION INHIBITION TEST FOR ETHYLENE GLYCOL ANTIFREEZE.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BL 001-1-2001 CORROSION INHIBITION TEST FOR ETHYLENE GLYCOL ANTIFREEZE.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、FORD LABORATORY TEST METHOD BL 001-01 2001 0820 CORROSION INHIBITION TEST FOR ETHYLENE GLYCOL ANTIFREEZE Revised Editorial - no technical change A. Cockman Application This test is a glassware corrosion test used to determine the inhibiting ability of ethylene glycol antifreeze. This procedure is us
2、ed as a screening test for new formulations and as a control test for checking uniformity of production shipments. Apparatus Required Metal Specimens - to conform to the following types: COPPER: (ASTM B 152) (SAE 71) cold rolled sheet stock. Type ETP or STP of the standard specification for copper s
3、heet, plate or rolled bar SOLDER: Brass specimen with chamfered edges hot dip coated with solder Alloy Grade 30A or 30B of the specifications for solder metal (ASTM B 32). Alternate: Solid solder metal specimen of Alloy Grade 30A or 30B of the specifications for solder metal (ASTM B 32). BRASS: Allo
4、y No. 8 of the standard specification for brass plate, sheet, strip and rolled bar (ASTM B 36) (SAE 70C) - half hard. STEEL: SAE 1020, cold rolled sheet stock. CAST IRON: Alloy No. 120 of the tentative specifications for automotive gray iron castings (ASTM D 159) (SAE 120). CAST ALUMINUM: Alloy SC 6
5、4C of the tentative specifications for aluminum-base alloys in ingot form for sand castings, die castings, and permanent mold castings (ASTM B 179) (SAE 329). Note: Complete sets are available from: Chemical Specialties Manufacturers Association 50 East 41st Street New York. NY I Date I Action I Rev
6、isions I Copynght02001, Ford Global Technologies, Inc FORD LABORATORY TEST METHOD BL 001-01 Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 OC and 50 +/- 5 % relative humidity for not less than 24 h prior to t
7、esting and tested under the same conditions unless otherwise specified. Procedure Test Specimen Assembly Metal specimens shall be cut to a 1 x 2 x 1/16 inch size with the exception of cast specimens which are 1/8 inch thick. Drill a 1/4 inch hole in the center of each specimen. The cast iron and alu
8、minum surfaces are sanded with a 150 grit aluminum oxide paper. Scrub all specimens with a moistened soft bristle brush and pumice powder until a surface free of water break is obtained. Rinse the specimens thoroughly with tap water, dip in acetone, dry and weigh to the nearest milligram. Cover a 10
9、-24 brass machine screw with a thin-walled insulating tubing, having an outside diameter of less than 1/4 inch. Two brass legs are prepared from sheet stock to a size of 1 x 2 x 1/16 inch. A 1/4 inch hole is located with the center 1/4 inch from the top and 1/2 inch from each side. Mount specimens o
10、n the insulating screw in the following order: Brass leg, copper, solder, brass, steel, cast iron, aluminum, brass leg. Specimens are separated with 3/16 inch spacers, having an inside diameter of 1/4 inch and an outside diameter of less than 0.40 inch. Insulating spacers are used between the legs a
11、nd specimens and between brass and steel. Brass spacers are used between copper, solder and brass. Steel spacers are used between steel, cast iron and aluminum. The nut shall be tightened firmly to assure good electrical contact. (See sketch.) Triplicate tests shall be made on each solution. A 750 m
12、L volume of test coolant is added to a 1 O00 mL tall form, lipless beaker, fitted with a No. 15 rubber stopper which has holes to accommodate a condenser and aerator tube. An air condenser of glass tubing, 20 inches in length and an inside diameter of 10 mm may be used but a water condenser of the r
13、eflux type is preferred. An aerator tube of the gas dispersion type with 12-C porosity size is used. (Corning Glass Works, 44 Crystal St., Corning N.Y., Tube No. 39533, or equivalent.) A synthetic water shall be used for all water additions in making up the test solution as follows: (a) For coolant
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。