FORD FLTM BJ 007-07-2001 TEST FOR CORROSION CLEANABILITY AND PHOSPHATABILITY OF STEEL TREATED WITH DRAW COMPOUNDS AND RUST PREVENTATIVE OILS《经拉拔用润滑剂和防锈油处理的钢制品的腐蚀、可清洁性和可磷化处理性的试验》.pdf
《FORD FLTM BJ 007-07-2001 TEST FOR CORROSION CLEANABILITY AND PHOSPHATABILITY OF STEEL TREATED WITH DRAW COMPOUNDS AND RUST PREVENTATIVE OILS《经拉拔用润滑剂和防锈油处理的钢制品的腐蚀、可清洁性和可磷化处理性的试验》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BJ 007-07-2001 TEST FOR CORROSION CLEANABILITY AND PHOSPHATABILITY OF STEEL TREATED WITH DRAW COMPOUNDS AND RUST PREVENTATIVE OILS《经拉拔用润滑剂和防锈油处理的钢制品的腐蚀、可清洁性和可磷化处理性的试验》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BJ 007-07 Date Action Revisions 2001 07 24 Revised Editorial no technical change A. Cockman 1992 05 06 Printed copies are uncontrolled Page 1 of 5 Copyright 2001, Ford Global Technologies, Inc. TEST FOR CORROSION, CLEANABILITY AND PHOSPHATABILITY OF STEEL TREATED WITH DR
2、AW COMPOUNDS AND RUST PREVENTATIVE OILS Application This procedure is used to evaluate the effects of rust preventatives and draw compounds on steel relative to corrosion, cleanability and ability to be phosphated. It involves exposing steel panels which have been coated with the rust preventative o
3、r draw compound in question to a condensing water vapor atmosphere. The panels are then evaluated, cleaned and phosphated and subsequently reevaluated. Apparatus Required Humidity Cabinet Cleveland Condensing Humidity Cabinet or equivalent. Source: Q-Panel Company 15610 Industrial Parkway Cleveland,
4、 Ohio 44135 Steel Parker Test Panels 75 x 230 mm, polished, clean treatment. Source: Parker Division O.M.I. Corp. 322 Main Street Morenci, Michigan 48256 Wet Film Applicator Gardner Film Applicator or equivalent. Draw bar clearances equal to 0.005 mm and 0.08 mm required. Source: Gardner Laboratory
5、Division 5521 Landy Lane Bethesda, Maryland 20014 Glass Blanks 3 x 100 x 200 mm. FORD LABORATORY TEST METHOD BJ 007-07 Page 2 of 5 Copyright 2001, Ford Global Technologies, Inc. Materials Required Isopropanol Reagent grade - uncontaminated and undiluted. Caution: Low flash point - refer to Fire Cont
6、rol Bulletin No. 18. Refer to Industrial Hygiene for health and safety comments. Mineral Seal Oil M-558 - refer to Industrial Hygiene Bulletin No. 3 for use and handling of petroleum oils. Kerosene Caution: Low flash point - refer to Fire Control Bulletin No. 18. Refer to Industrial Hygiene for heal
7、th and safety comments. Test Grid Transparent grid marked off with a section 50 x 230 mm. (Refer to Figure 2.) Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less th
8、an 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure Procedure “A“ - Drawing Oils and Compounds 1. Lay steel panels horizontally on a flat surface over paper toweling. Wipe polished surface clean with isopropanol. Air dry thoroughly. 2. Mix compounds as
9、 specified by plant use, Manufacturing Standard or supplier recommendations. 3. Apply oil or mixed compound to upper quarter of panel face, drawing down with applicator (draw bar clearance equal to 0.08 mm) to achieve a wet film 50 mm wide. 4. Hang or stand panels upright; allow to air dry 8 h at 23
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBJ007072001TESTFORCORROSIONCLEANABILITYANDPHOSPHATABILITYOFSTEELTREATEDWITHDRAWCOMPOUNDSANDRUSTPREVENTATIVEOILS

链接地址:http://www.mydoc123.com/p-747084.html