《FORD FLTM BI 155-01-2001 DETERMINATION OF THE BEHAVIOR OF ELECTROSTATIC PAINT UNDER HIGH VOLTAGE CONDITIONS (Replaces FLTM EU-BI 055-01)《高压条件下静电喷涂行为的测定 代替FLTM EU-BI 055-01》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BI 155-01-2001 DETERMINATION OF THE BEHAVIOR OF ELECTROSTATIC PAINT UNDER HIGH VOLTAGE CONDITIONS (Replaces FLTM EU-BI 055-01)《高压条件下静电喷涂行为的测定 代替FLTM EU-BI 055-01》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BI 155-01 Date Action Revisions 2001 03 20 Revised Editorial no technical change A. Cockman 1999 01 19 Printed copies are uncontrolled Page 1 of 5 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF THE BEHAVIOR OF ELECTROSTATIC PAINT UNDER HIGH VOLTAGE CONDI
2、TIONS Application This method is used to determine the behavior of electrostatic paint in a pumped circulating system. It may also be used to determine the spray application properties of electrostatic paint under laboratory conditions. Apparatus Required Electrostatic Testing Equipment Voltage rang
3、e up to 100 kV dc. Source: M.W. Test Equipment Faraday House 10, Lind Road Sutton Surrey SM1 4PG England Phone: 44-181-661-9963 Fax: 44-181-642-4801 XYT Recorder Input sensitivity 0.05 - 25 mV/cm, or other suitable instrument for measuring current and voltage. Pump For an enamel flow of 500 +/- 10 m
4、L/minute with an electromagnetic valve. Infinitely Variable Speed Transm ission - for the pump Enamel Container - 1.5 L with stirrer Electrostatic Spray Gun Manual and automatic operation with special nozzle. Ransburg REA Super (Type 301/14299) manual operation. Conventional Hand Spray Gun - DeVilbi
5、ss Type JG A 502, or equivalent FORD LABORATORY TEST METHOD BI 155-01 Page 2 of 5 Copyright 2001, Ford Global Technologies, Inc. Paint Mixer - according to FLTM BI 103-02 Laboratory Forced Air Oven - according to FLTM BI 103-02 Thickness Gauge - according to FLTM BI 117-01 Test Panels Steel body ski
6、n panels ground to a surface of 0.457 - 0.508 mm Ra, or otherwise specified in the relevant Engineering Material Specification. Panel size 500 x 500 mm, or otherwise specified in the relevant Engineering Material Specification. Spray Booth - according to FLTM BI 103-02 Nozzle - for electrostatic spr
7、aying Behr System - Model No. TOS1/2A12/12K. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unle
8、ss otherwise specified. Procedure A. Determination of the behavior of electrostatic paint (under high voltage conditions) in a pumped circulatory system (see sketch on Page 4). 1. Transfer 1 liter of an adequately mixed paint, reduced to the operating spraying viscosity, into the enamel container an
9、d pump at a flow of 500 +/- 10 mL/minute through the measuring section tube. Mixing: The can of test material must be mixed for ten minutes. After mixing, the paint is stirred with a spatula ensuring that the tip is in contact with the bottom of the can. Mixing is adequate if no evidence of settling
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBI155012001DETERMINATIONOFTHEBEHAVIOROFELECTROSTATICPAINTUNDERHIGHVOLTAGECONDITIONSREPLACESFLTMEUBI05501

链接地址:http://www.mydoc123.com/p-747042.html