FORD FLTM AZ 003-06-2000 RETENTIVITY OF ACTIVATED CARBON《活性炭的活性保持性》.pdf
《FORD FLTM AZ 003-06-2000 RETENTIVITY OF ACTIVATED CARBON《活性炭的活性保持性》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM AZ 003-06-2000 RETENTIVITY OF ACTIVATED CARBON《活性炭的活性保持性》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD AZ 003-06 Date Action Revisions 2000 08 30 Revised Editorial no technical change A. Cockman 2000 05 22 Revised Editorial no technical change A. Cockman 1992 03 19 Printed copies are uncontrolled Page 1 of 5 Copyright 2000, Ford Global Technologies, Inc. RETENTIVITY OF AC
2、TIVATED CARBON Application Purified dry air is passed through a carbon tetrachloride - saturated sample for six hours under specified conditions. The percentage of carbon tetrachloride retained by the carbon is its retentivity. Apparatus Required The apparatus is shown diagrammatically in figures 1
3、and 2. It consists of the following: Pressure Regulator - A Reduces air line pressure to 34.5 kPa, Type 11 - 0004. Source: C. A. Norgren Company 5400 S. Delaware Street Littleton, Colorado 80120 or equivalent. Graduate - B 100 mL, Catalog No. 8 - 553 - B, Fisher Scientific or equivalent. Aspirator B
4、ottle - C, D Three 2 liter, (C) Activated Carbon, (D) Calcium Chloride, (D) Calcium Chloride. Catalog No. 2 -972 - E, Fisher Scientific or equivalen t. Insulated Box - J This may be an ordinary insulated picnic box. Needle Valve - G Stainless steel, for air control, Catalog No. 10 - 583, Fisher Scie
5、ntific or equivalent. Flowmeter U Tube - H Catalog No. 11 - 286, Fisher Scientific or equivalent. Activity Tube - I The carbon sample tube shown in figure 2 is a hard glass, “U“ shaped tube, 190 mm long, having an inside diameter in the larger leg of the tube of 14.1 mm. A perforated porcelain disc
6、is fused to the wall of this tube at the lower end approxima tely 40 mm from the bottom, and a line is marked on the tube exactly 100 mm above the surface of the disc. When filled to the 100 mm mark, the tube holds 15.7 mL of the sample. This part must be custom made. FORD LABORATORY TEST METHOD AZ
7、003-06 Page 2 of 5 Copyright 2000, Ford Global Technologies, Inc. Source: Leonard Glass Blowing 867 McKinley Av enue Columbus, Ohio 43222 or equivalent. Laboratory Balance Accurate to 0.01 g Rubber Stoppers One No. 5 1/2, 1 hole, No. 14 - 135 Fisher Scientific or equivalent. Three No. 8, 1 hole, No.
8、 14 - 135 Fisher Scientific or equivalent. One No. 1, 1 hole, No. 14 - 135 Fisher Scientific or equivalent. Capillary Tubing 3.0 - 5.0 m; inside diameter, 1 mm and 2 mm, Catalog No. 11 - 360 - B, Fisher Scientific or equivalent. Glass Tubing 6.0 - 8.0 m; inside diameter 6 mm, Catalog No. 11 - 350, F
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMAZ003062000RETENTIVITYOFACTIVATEDCARBON 活性炭 活性 保持 PDF

链接地址:http://www.mydoc123.com/p-746856.html