FORD ESB-M4G331-A-2014 SEALER POLYOLEFIN HOT MELT THERMOSETTING EXTRUDED NON-FLOW TO BE USED WITH FORD WSS-M99P1111-A .pdf
《FORD ESB-M4G331-A-2014 SEALER POLYOLEFIN HOT MELT THERMOSETTING EXTRUDED NON-FLOW TO BE USED WITH FORD WSS-M99P1111-A .pdf》由会员分享,可在线阅读,更多相关《FORD ESB-M4G331-A-2014 SEALER POLYOLEFIN HOT MELT THERMOSETTING EXTRUDED NON-FLOW TO BE USED WITH FORD WSS-M99P1111-A .pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONMaterial Name Specification NumberDate Action Changes1990 10 19 NB00E10071915001 Released W. Curtiss E. Rezendes M. PerchardWP 3948-a Page 1 of 6 SEALER, POLYOLEFIN, HOT MELT, THERMOSETTING, ESB-M4G331-AEXTRUDED, NON-FLOW1. SCOPEThe material defined by this specifi
2、cation is an extruded hot meltthermosetting polyolefin based sealer which is non-flowable.2. APPLICATIONThis specification was released originally for materials used overelectrocoated steel to seal horizontal and vertical lap joints, such as onthe floor pan, and recessed joints such as quarter panel
3、 to rocker panel.It is suitable for use involving interior exposure and is paintable withtopcoat enamels presenting an acceptable appearance free from tackiness,checks and porosity. Slight yellow staining is acceptable. Not suitable forClass “A“ surfaces.3. REQUIREMENTS3.1 STATISTICAL PROCESSSupplie
4、rs must conform to the requirements of Ford Quality SystemStandard Q-101. A mutually acceptable Control Plan as describedtherein is required for material/source approval. Appropriatestatistical tools must be used to analyze process/product data sothat variation in the final product is continuously r
5、educed.3.2 INFRARED SPECTROPHOTOMETRY AND/OR THERMAL ANALYSISAll samples shall produce spectra or thermograms that correspond tothe reference standard when tested under the same conditions. Theinfrared spectra or thermograms established for initial approvalshall constitute the reference standard and
6、 shall be kept on file atthe designated material laboratory.3.3 CONDITIONING AND TEST CONDITIONSAll test values indicated herein are based on materials conditionedin a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relativehumidity for not less than 24 h prior to testing and tested under thesame
7、 conditions unless otherwise specified.NOT TO BE USED FOR NEW DESIGN 2014 N Status No replacement named L. Sinclair, NAENGINEERING MATERIAL SPECIFICATIONESB-M4G331-AWP 3948-b Page 2 of 6 3.4 HARDNESS, DUROMETER A 60 - 80(ASTM D 2240)3.4.1 As received3.4.2 Aged 72 h at 49 CThe ha rdness tolerance for
8、 any one supplier shall be +/- 5hardness units based on the recorded hardness va lue for theiroriginally approved production sample.3.5 SOLIDS, min 98 %(ASTM D 2046, except heat at 190 +/- 2 Cfor 3 h in a mechanical convection oven)3.6 ASH (Based on solids weight), max 50 %Test Method: Place the cru
9、cible containing the solids residue in acool muffle furnace. S lowly heat and maintain at 760 +/- 30 C for 1h, cool in desiccator and weigh.3.7 SPECIFIC GRAVITY 1.10 - 1.30(ASTM D 792)3.8 PAINT COMPATIBILITYNo tackiness or crackin g effects on light colored enamel as a resultof painting.Test Method:
10、. Apply an extruded section of material 150 x 25 x 1.5 - 2.0 mm tofour 75 x 225 x 0.89 mm electrocoated steel panels per para 5.3. Bake sample per para. 5.4.1. Cool to 23 +/- 2 C and examine. . Spray with currently released white (two panels) and light metallicenamels (two panels), and bake per para
11、 5.4. Use currently releasedenamels. Cool to 23 +/- 2 C and reexamine for any of the aboveconditions.3.9 FLOW PROPERTIES, max Vertical Horizontal1 mm 1 mmTest Method:. Apply an extruded section of sealer 150 x 25 x 1.5 - 2.0 mm totwo 300 x 300 x 0.89 mm electrocoated steel panels per para5.3. Prehea
12、t the panels for 15 minutes at 90 +/- 2 C prior tosealer application. This will heat stake t he sealer to the panel.Allow the panels to cool at 23 +/- 2 C for 30 minutes.ENGINEERING MATERIAL SPECIFICATIONESB-M4G331-AWP 3948-b Page 3 of 6 . Place the panels in a mechanical convection o ven for 15 min
13、utes at150 +/- 2 C. Place one panel in a vertical position with the 150 mmdimension of sealer in a horizontal attitude and the second panelin a horizontal position. Remove panels from oven, cool, and measure the increase indimension. Save panels for para 3.10.2.3.10 LOW TEMPERATURE RESISTANCE No cra
14、cking oradhesion failure3.10.1 Flexib ility: The sealer must withstand a 180 degree bendaround a 25 mm diameter mandrel at 23 +/- 2 C and - 30 +/- 2C.3.10.2 Adhesion: Place the panels prepared in para 3.9 in theslamming apparatus desc ribed in FLTM BV 101-02 and condition4 h at - 30 +/- 2 C. The pan
15、el shall be slammed a total ofsix times.3.11 REFLOW RESISTANCE No loss of adhesion or reflow afterfive cyclesTest Method: Apply an extruded section of sealer 150 x 25 x 1.5 -2.0 mm lon g on a 75 x 225 x 0.8 mm panel per 5.3 and bake per para5.4. Expose each sample for 5 cycles, each cycle consisting
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESBM4G331A2014SEALERPOLYOLEFINHOTMELTTHERMOSETTINGEXTRUDEDNONFLOWTOBEUSEDWITHFORDWSSM99P1111APDF

链接地址:http://www.mydoc123.com/p-745614.html