FORD ESA-M1L77-A-2003 CABLE LOW TENSION - VINYL INSULATED - STRANDED FLEXIBLE TO BE USED WITH FORD WSS-M99P1111-A 《柔性多股胶合的乙烯基绝缘的低压电缆 与标准FORD WSS-M99P1111-A一起使用 》.pdf
《FORD ESA-M1L77-A-2003 CABLE LOW TENSION - VINYL INSULATED - STRANDED FLEXIBLE TO BE USED WITH FORD WSS-M99P1111-A 《柔性多股胶合的乙烯基绝缘的低压电缆 与标准FORD WSS-M99P1111-A一起使用 》.pdf》由会员分享,可在线阅读,更多相关《FORD ESA-M1L77-A-2003 CABLE LOW TENSION - VINYL INSULATED - STRANDED FLEXIBLE TO BE USED WITH FORD WSS-M99P1111-A 《柔性多股胶合的乙烯基绝缘的低压电缆 与标准FORD WSS-M99P1111-A一起使用 》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Material Name Specification Number Date Action Revisions 2003 04 25 Revised Para 3.0 inserted; Para 3.5 & 4 deleted 1981 10 07 CAL1-RD588050-7 Metricated and Retyped, Released by BEPE 1964 06 11 Release AS2-465 Printed copies are uncontrolled Page 1 of 4 Copyright
2、 2003, Ford Global Technologies, Inc. CABLE, LOW TENSION - VINYL INSULATED - STRANDED, FLEXIBLE ESA-M1L77-A 1. SCOPE The material defined by this specification is a stranded vinyl covered low tension flexible cable. The vinyl covering shall have a maximum service temperature of 85 C. 2. APPLICATION
3、This specification was released originally for material used for automotive electrical wiring. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1 CO
4、LOR The color of the vinyl cover shall be specified on the engineering drawing and/or release by a numerical suffix following the letter suffix of the material desired. The numerical color coding suffixes shall correspond to the following: 0 - Black 5 - Green 1 - Brown 6 - Blue 2 - Red 7 - Violet 3
5、- Orange 8 - Gray 4 - Yellow 9 - White or natural The first color coding numerical suffix shall be the base or body color of the finished cable and the second number shall designate the tracer or other auxiliary marking. 3.2 CABLE CONSTRUCTION See Table I 3.3 WIRE QUALITY The strands of the conducto
6、rs prior to stranding shall consist of ESF-M2L1-A, soft or annealed bare copper wire. ENGINEERING MATERIAL SPECIFICATION ESA-M1L77-A Page 2 of 4 Copyright 2003, Ford Global Technologies, Inc. 3.4 INSULATION QUALITY Shall be a good grade vinyl chloride copolymer which will pass the following test req
7、uirements: The material shall adhere closely to, but strip readily from the conductors, leaving them reasonably clean and in suitable condition for soldering. 3.4.1 Mechanical Properties (ASTM D 412 - Die “A“ 12 in (305 mm)/min speed) Standard laboratory test slabs shall be prepared by compression m
8、olding the thermoplastic material of the same composition and grade as used for the wire insulation. Tensile Strength, min 1900 psi (13.1 MPa) Elongation, min 125% 3.4.2 Dielectric Test A specimen of the cable 24 in (610 mm) long shall be formed into a loop. One in (25 mm) of the insulation shall be
9、 removed from each end of the wire and the ends twisted together. The loop thus formed shall be immersed in water containing 5% salt by weight at 23 +/- 2 C, so that not more than 6 in (152 mm) of each end of the specimen protrudes above the solution. After being immersed for 5 h and while still imm
10、ersed, the specimen shall withstand the application of 1000 V (rms) at 60 Hz frequency between the conductor and the water for 1 min without rupture of the insulation. 3.4.3 High Temperature Resistance One in (25 mm) of the insulation shall be removed from each end of a 24 in (610 mm) sample of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESAM1L77A2003CABLELOWTENSIONVINYLINSULATEDSTRANDEDFLEXIBLETOBEUSEDWITHFORDWSSM99P1111A 柔性 胶合 乙烯基

链接地址:http://www.mydoc123.com/p-744870.html