ETSI ES 202 336-11-2014 Environmental Engineering (EE) Monitoring and control interface for infrastructure equipment (Power Cooling and environment systems used in telecommunicatio_1.pdf
《ETSI ES 202 336-11-2014 Environmental Engineering (EE) Monitoring and control interface for infrastructure equipment (Power Cooling and environment systems used in telecommunicatio_1.pdf》由会员分享,可在线阅读,更多相关《ETSI ES 202 336-11-2014 Environmental Engineering (EE) Monitoring and control interface for infrastructure equipment (Power Cooling and environment systems used in telecommunicatio_1.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI ES 202 336-11 V1.1.1 (2014-09) Environmental Engineering (EE); Monitoring and control interface for infrastructure equipment (Power, Cooling and environment systems used in telecommunication networks); Part 11: Battery system with integrated control and monitoring information model ETSI STANDA
2、RD ETSI ETSI ES 202 336-11 V1.1.1 (2014-09)2Reference DES/EE-02037-11 Keywords battery, control, interface, management, power, system ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association b
3、ut non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice The present document can be downloaded from: http:/www.etsi.org The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present
4、 document shall not be modified without the prior written authorization of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive
5、 within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present do
6、cument, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written
7、permission of ETSI. The content of the PDF version shall not be modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2014. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMa
8、nd the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI ES
9、 202 336-11 V1.1.1 (2014-09)3Contents Intellectual Property Rights 4g3Foreword . 4g3Modal verbs terminology 4g31 Scope 5g32 References 5g32.1 Normative references . 5g32.2 Informative references 5g33 Definitions, symbols and abbreviations . 6g33.1 Definitions 6g33.2 Symbols 8g33.3 Abbreviations . 8g
10、34 Integrated Battery Unit (IBU) and Integrated Battery System (IBS) control and monitoring presentation 9g3Annex A (normative): Summary of mandatory monitoring/supervision information and functions 12g3A.1 Integrated Battery Unit (IBU) and Integrated Battery System (IBS) . 13g3Annex B (informative)
11、: Summary of non-mandatory monitoring/supervision information and functions 14g3B.1 Integrated Battery Unit (IBU) and Integrated Battery System (IBS) . 14g3Annex C (normative): Mandatory XML structure and elements 16g3C.1 Structure of an XML document for Telecom/ICT IBS control and monitoring. 16g3C
12、.2 The specific XML elements of a Telecom/ICT IBS 17g3Annex D (informative): Bibliography . 18g3History 19g3ETSI ETSI ES 202 336-11 V1.1.1 (2014-09)4Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining
13、 to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat.
14、 Latest updates are available on the ETSI Web server (http:/ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETS
15、I Web server) which are, or may be, or may become, essential to the present document. Foreword This ETSI Standard (ES) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document is part 11 of a multi-part deliverable covering Monitoring and control interface f
16、or infrastructure equipment (Power, Cooling and environment systems used in telecommunication networks), as identified below: Part 1: “Generic Interface“; Part 2: “DC power system control and monitoring information model“; Part 3: “AC UPS power system control and monitoring information model“; Part
17、4: “AC distribution power system control and monitoring information model“; Part 5: “AC diesel back-up generator system control and monitoring information model“; Part 6: “Air Conditioning System control and monitoring information model“; Part 7: “Other utilities system control and monitoring inform
18、ation model“; Part 8: “Remote Power Feeding System control and monitoring information model“. Part 9: “Alternative Power Systems“; Part 10: “AC inverter power system control and monitoring information model“; Part 11: “Battery system with integrated control and monitoring information model“; Part 12
19、: “Telecom/ICT equipment control and monitoring information model“. Modal verbs terminology In the present document “shall“, “shall not“, “should“, “should not“, “may“, “may not“, “need“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI
20、Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. ETSI ETSI ES 202 336-11 V1.1.1 (2014-09)51 Scope The present document applies to Battery Systems with integral control and monitoring for te
21、lecommunication and datacom (ICT) equipment. It applies to battery system with a dedicated monitoring and control unit. The present document defines: Monitored and controlled battery system architectures. The minimum set of exchanged information required at the interface, described in “natural langu
22、age“ in text tables. The XML files with tags and variables corresponding to the data in the tables of the annexes. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version
23、applies. For non-specific references, the latest version of the reference document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. NOTE: While any hyperlinks included in
24、this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are necessary for the application of the present document. 1 ETSI ES 202 336-1: “Environmental Engineering (EE); Monitoring and Control Inter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIES202336112014ENVIRONMENTALENGINEERINGEEMONITORINGANDCONTROLINTERFACEFORINFRASTRUCTUREEQUIPMENTPOWERCOOLINGANDENVIRONMENTSYSTEMSUSEDINTELECOMMUNICATIO_1PDF

链接地址:http://www.mydoc123.com/p-730908.html