ETSI EN 300 386-2016 Telecommunication network equipment ElectroMagnetic Compatibility (EMC) requirements Harmonised Standard covering the essential requirements of the Directive 2.pdf
《ETSI EN 300 386-2016 Telecommunication network equipment ElectroMagnetic Compatibility (EMC) requirements Harmonised Standard covering the essential requirements of the Directive 2.pdf》由会员分享,可在线阅读,更多相关《ETSI EN 300 386-2016 Telecommunication network equipment ElectroMagnetic Compatibility (EMC) requirements Harmonised Standard covering the essential requirements of the Directive 2.pdf(54页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI EN 300 386 V2.1.1 (2016-07) Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements; Harmonised Standard covering the essential requirements of the Directive 2014/30/EU HARMONISED EUROPEAN STANDARD ETSI ETSI EN 300 386 V2.1.1 (2016-07) 2 Reference REN/ERM-EMC-330
2、Keywords EMC, harmonised standard, network, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important no
3、tice The present document can be downloaded from: http:/www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authori
4、zation of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be
5、 aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at https:/portal.etsi.org/TB/ETSIDeliverableStatus.aspx If you find errors in the present document, please send your comment to one of the followin
6、g services: https:/portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF vers
7、ion shall not be modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2016. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks of ETSI regist
8、ered for the benefit of its Members. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI EN 300 386 V2.1.1 (2016-07) 3 Contents Intellectu
9、al Property Rights 6g3Foreword . 6g3Modal verbs terminology 6g31 Scope 7g32 References 8g32.1 Normative references . 8g32.2 Informative references 10g33 Definitions and abbreviations . 12g33.1 Definitions 12g33.2 Abbreviations . 15g34 Installation environment . 16g35 Immunity: test methods 16g35.0 G
10、eneral requirements . 16g35.1 Electrostatic discharge 17g35.2 Electrical fast transients/burst . 17g35.3 Surges . 17g35.3.1 Signal line ports 17g35.3.2 AC power ports . 17g35.4 Immunity to continuous conducted signals 17g35.4.1 Low frequency ( 150 kHz) 17g35.4.2 Radio frequency ( 150 kHz) . 17g35.4.
11、2.1 AC power port . 17g35.4.2.2 DC power port . 18g35.4.2.3 Signal line port 18g35.5 Immunity to radiated electromagnetic fields 18g35.6 Immunity to power supply disturbances: AC and DC power ports 18g35.6.1 Test of immunity to low frequency disturbances: AC power ports 18g35.6.2 Test of immunity to
12、 low frequency disturbances: DC power ports 18g36 Emission: test methods . 18g36.0 General . 18g36.1 AC power port 18g36.2 DC power port 19g36.3 Wired network and telecommunication Ports. 19g36.4 Radiated emission. 19g37 Test levels and limits 19g37.0 General requirements . 19g37.1 Emission . 20g37.
13、1.1 Enclosure port, Radiated electromagnetic field emissions 20g37.1.2 AC ports 20g37.1.2.1 Conducted emissions . 20g37.1.2.2 Current harmonics. 20g37.1.2.3 Voltage fluctuations 20g37.1.3 DC ports, Conducted emissions 20g37.1.4 Wired network or Telecommunication ports, Conducted emissions 20g37.2 Im
14、munity 21g37.2.1 Equipment operating in telecommunication centres . 21g37.2.1.1 Telecommunication centres, enclosure port 21g37.2.1.2 Telecommunication centres, ports for outdoor signal lines . 22g37.2.1.3 Telecommunication centres, ports for indoor signal lines . 23g37.2.1.4 Telecommunication centr
15、es, AC power ports . 24g37.2.1.5 Telecommunication centres, DC power ports . 24g37.2.2 Equipment operating in locations other than telecommunication centres . 25g3ETSI ETSI EN 300 386 V2.1.1 (2016-07) 4 7.2.2.1 Other than telecommunication centres, enclosure port . 25g37.2.2.2 Other than telecommuni
16、cation centres, ports for outdoor signal lines 26g37.2.2.3 Other than telecommunication centres, ports for indoor signal lines 27g37.2.2.4 Other than telecommunication centres, AC power ports . 28g37.2.2.5 Other than telecommunication centres, DC power ports . 29g38 General test configuration 30g39
17、General operational conditions during testing 30g39.0 General requirements . 30g39.1 Equipment configuration 30g39.2 Operation of multimedia network equipment . 31g310 General immunity conditions . 31g310.0 General . 31g310.1 General performance criteria 31g311 Switching equipment specific requireme
18、nts . 32g311.1 Test configuration. 32g311.2 Operational conditions . 33g311.2.0 General 33g311.2.1 Emission . 34g311.2.2 Immunity 34g311.3 Specific immunity performance criteria . 34g311.3.0 General 34g311.3.1 Digital port performance criteria 34g311.3.1.1 Performance criterion A (continuous phenome
19、na) 34g311.3.1.2 Performance criterion B (transient phenomena) 34g311.3.1.3 Performance criterion C (interruptions) 34g311.3.2 Analogue port performance criteria 34g311.3.2.1 Performance criterion A (continuous phenomena) 34g311.3.2.2 Performance criterion B (transient phenomena) 35g311.3.2.3 Perfor
20、mance criterion C (interruptions) 35g312 Transmission equipment specific requirements . 35g312.1 Test configuration. 35g312.2 Operational conditions . 36g312.2.0 General 36g312.2.1 Emission . 36g312.2.2 Immunity 36g312.3 Specific immunity performance criteria . 36g312.3.1 Digital signal ports 36g312
21、.3.1.0 General 36g312.3.1.1 Performance criterion A (continuous phenomena) 36g312.3.1.2 Performance criterion B (transient phenomena) 37g312.3.1.3 Performance criterion C (interruptions) 37g312.3.2 Analogue voice frequency signal ports . 37g312.3.2.0 General 37g312.3.2.1 Performance criterion A (con
22、tinuous phenomena) 37g312.3.2.2 Performance criterion B (transient phenomena) 37g312.3.3 SDH and PDH interfaces 37g312.3.3.1 Tributary and aggregate interfaces 37g312.3.4 ISDN interfaces 37g312.3.4.1 Primary rate access ISDN interfaces . 37g312.3.4.2 Network termination NT1 for ISDN “U“ interfaces 3
23、7g312.3.4.3 Basic access ISDN interfaces 38g312.3.5 Analogue interfaces 38g312.3.5.1 Trunk interfaces and leased line interfaces . 38g312.3.5.2 Subscriber interfaces . 38g312.3.6 V.10, V.11, V.24, V.28, V.36, X.24 and similar V.- and X.- series interfaces . 38g312.3.7 Ethernet and packet-data interf
24、aces 38g312.3.7.0 General 38g312.3.7.1 Performance criterion A (continuous phenomena) 38g312.3.7.2 Performance criterion B (transient phenomena) 38g3ETSI ETSI EN 300 386 V2.1.1 (2016-07) 5 12.3.8 Service and maintenance interfaces 38g312.3.9 Synchronization interfaces 38g312.3.9.0 General 38g312.3.9
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIEN3003862016TELECOMMUNICATIONNETWORKEQUIPMENTELECTROMAGNETICCOMPATIBILITYEMCREQUIREMENTSHARMONISEDSTANDARDCOVERINGTHEESSENTIALREQUIREMENTSOFTHEDIRECTIVE2PDF

链接地址:http://www.mydoc123.com/p-728347.html