ETSI EN 300 135-1-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Land Mobile Service Citizens- Band (CB) radio equipment Angle-modulated Citizens- Band radio e.pdf
《ETSI EN 300 135-1-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Land Mobile Service Citizens- Band (CB) radio equipment Angle-modulated Citizens- Band radio e.pdf》由会员分享,可在线阅读,更多相关《ETSI EN 300 135-1-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Land Mobile Service Citizens- Band (CB) radio equipment Angle-modulated Citizens- Band radio e.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI EN 300 135-1 V1.2.1 (2008-02)European Standard (Telecommunications series) Electromagnetic compatibilityand Radio spectrum Matters (ERM);Land Mobile Service;Citizens Band (CB) radio equipment;Angle-modulated Citizens Band radio equipment(PR 27 Radio Equipment);Part 1: Technical characteristics
2、 andmethods of measurementETSI ETSI EN 300 135-1 V1.2.1 (2008-02) 2 Reference REN/ERM-TGDMR-267-1 Keywords CB, radio, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non l
3、ucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived differe
4、nce in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that
5、 the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/por
6、tal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2008. All rights reserved. DECTTM, PLUG
7、TESTSTM, UMTSTM, TIPHONTM, the TIPHON logo and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI EN 300 135-1 V1.2.1 (2008-02) 3 Contents Intelle
8、ctual Property Rights6 Foreword.6 1 Scope 7 2 References 8 2.1 Normative references .8 2.2 Informative references8 3 Definitions, symbols and abbreviations .8 3.1 Definitions8 3.2 Symbols9 3.3 Abbreviations .9 4 General .9 4.1 Presentation of equipment for testing purposes9 4.1.1 Choice of model for
9、 testing 9 4.1.1.1 Auxiliary test equipment .10 4.1.1.2 Declarations by the provider .10 4.2 Testing of equipment that does not have an external 50 RF connector (integral antenna equipment) .10 4.3 Mechanical and electrical design10 4.3.1 General10 4.3.2 Controls 10 4.3.3 Push-to-talk (ptt) and voic
10、e activated switch10 4.3.4 Combination with other equipment 10 4.4 Declaration of conformity 11 5 Test conditions, power sources and ambient temperatures 11 5.1 Normal and extreme test conditions .11 5.2 Test power source.11 5.3 Normal test conditions11 5.3.1 Normal temperature and humidity11 5.3.2
11、Normal test power source .11 5.3.2.1 Mains voltage11 5.3.2.2 Regulated lead-acid battery power sources used on vehicles12 5.3.2.3 Other power sources12 5.4 Extreme test conditions 12 5.4.1 Extreme temperatures .12 5.4.2 Extreme test source voltages.12 5.4.2.1 Mains voltage12 5.4.2.2 Regulated lead-a
12、cid battery power sources used on vehicles12 5.4.2.3 Power sources using other types of batteries.12 5.4.2.4 Other power sources13 5.5 Procedure for tests at extreme temperatures.13 6 General test conditions .13 6.1 Arrangements for test signals applied to the receiver input13 6.2 Receiver mute or s
13、quelch facility.13 6.3 Receiver rated audio output power.13 6.4 Normal test modulation13 6.5 Artificial antenna13 6.6 Test fixture .14 6.7 Arrangement for test signals at the input of the transmitter .14 6.8 Test site and general arrangements for radiated measurements14 7 Method of measurement for t
14、ransmitter parameters 14 7.1 Frequency error 14 7.1.1 Definition14 7.1.2 Method of measurement .14 ETSI ETSI EN 300 135-1 V1.2.1 (2008-02) 4 7.1.3 Limit .15 7.2 Transmitter carrier power.15 7.2.1 Definition15 7.2.2 Method of measurement .15 7.2.2.1 Method of measurement (for equipment other than equ
15、ipment with integral antenna only) 15 7.2.2.2 Method of measurement for equipment with integral antenna15 7.2.3 Limits16 7.3 Maximum permissible frequency deviation .16 7.3.1 Definition16 7.3.2 Method of measurement .16 7.3.3 Limit .16 7.4 Adjacent channel power .16 7.4.1 Definition16 7.4.2 Method o
16、f measurement .16 7.4.3 Limit .17 7.5 Unwanted emissions in the spurious domain17 7.5.1 Definition17 7.5.2 Method of measurement .17 7.5.2.1 Method of measuring the power level in a specified load.17 7.5.2.2 Method of measuring the effective radiated power.18 7.5.2.3 Method of measuring the effectiv
17、e radiated power.18 7.5.3 Limits18 7.6 Transient behaviour of the transmitter19 7.6.1 Definitions 19 7.6.2 Method of measurement .20 7.6.3 Limits21 8 Methods of measurement for receiver parameters .22 8.1 Spurious radiations.22 8.1.1 Definition22 8.1.2 Method of measurement .22 8.1.2.1 Method of mea
18、suring the power level in a specified load.22 8.1.2.2 Method of measuring the effective radiated power.22 8.1.2.3 Method of measuring the effective radiated power.23 8.1.3 Limits23 9 Measurement uncertainty .23 Annex A (normative): Radiated measurement25 A.1 Test sites and general arrangements for m
19、easurements involving the use of radiated fields.25 A.1.1 Outdoor test site .25 A.1.1.1 Test site for handportable stations 25 A.1.2 Test antenna26 A.1.3 Substitution antenna .26 A.1.4 Optional additional indoor site .27 A.2 Guidance on the use of radiation test sites .27 A.2.1 Measuring distance.28
20、 A.2.2 Test antenna28 A.2.3 Substitution antenna .28 A.2.4 Artificial antenna28 A.2.5 Auxiliary cables28 A.3 Further optional alternative indoor test site using an anechoic chamber .28 A.3.1 Example of the construction of a shielded anechoic chamber29 A.3.2 Influence of parasitic reflections in anec
21、hoic chambers.29 A.3.3 Calibration of the shielded anechoic chamber30 Annex B (normative): Specification for adjacent channel power measurement arrangements32 B.1 Power measuring receiver specification.32 B.1.1 IF filter .32 ETSI ETSI EN 300 135-1 V1.2.1 (2008-02) 5 B.1.2 Variable attenuator .33 B.1
22、.3 Rms value indicator33 B.1.4 Oscillator and amplifier33 Annex C (informative): Bibliography.34 History 35 ETSI ETSI EN 300 135-1 V1.2.1 (2008-02) 6 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertainin
23、g to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat
24、. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the u
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIEN30013512008ELECTROMAGNETICCOMPATIBILITYANDRADIOSPECTRUMMATTERSERMLANDMOBILESERVICECITIZENSBANDCBRADIOEQUIPMENTANGLEMODULATEDCITIZENSBANDRADIOEPDF

链接地址:http://www.mydoc123.com/p-727904.html