EN ISO 20486-2018 en Non-destructive testing - Leak testing - Calibration of reference leaks for gases.pdf
《EN ISO 20486-2018 en Non-destructive testing - Leak testing - Calibration of reference leaks for gases.pdf》由会员分享,可在线阅读,更多相关《EN ISO 20486-2018 en Non-destructive testing - Leak testing - Calibration of reference leaks for gases.pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Non-destructive testing - Leak testing - Calibration of reference leaks for gases (ISO 20486:2017)BS EN ISO 20486:2018National forewordThis British Standard is the UK implementation of EN ISO 20486:2018. It is identical
2、 to ISO 20486:2017. It supersedes BS EN 13192:2002, which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee WEE/46, Non-destructive testing.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does
3、not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2018 Published by BSI Standards Limited 2018ISBN 978 0 580 94918 0ICS 19.100Compliance with a British Standard cannot confer immunity from legal obl
4、igations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2018.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN ISO 20486:2018EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN ISO 20486February 20
5、18ICS 19.100 Supersedes EN 13192:2001EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGCEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2018 CEN Ref. No. EN ISO 20486:2018: EAll rights of exploitation in any form and by any means reserv
6、ed worldwide for CEN national MembersNon-destructive testing - Leak testing - Calibration of reference leaks for gases (ISO 20486:2017)Essais non destructifs - Contrle dtanchit - talonnage des fuites de rfrence des gaz (ISO 20486:2017)Zerstrungsfreie Prfung - Dichtheitsprfung - Kalibrieren von Refer
7、enzlecks fr Gase (ISO 20486:2017)This European Standard was approved by CEN on 23 December 2017.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-d
8、ate lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
9、 under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Form
10、er Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.English VersionEN ISO 20486:2018 (E)Eu
11、ropean forewordThis document (EN ISO 20486:2018) has been prepared by Technical Committee ISO/TC 135 “Non-destructive testing“ in collaboration with Technical Committee CEN/TC 138 “Non-destructive testing”, the secretariat of which is held by AFNOR.This European Standard shall be given the status of
12、 a national standard, either by publication of an identical text or by endorsement, at the latest by August 2018, and conflicting national standards shall be withdrawn at the latest by August 2018.Attention is drawn to the possibility that some of the elements of this document may be the subject of
13、patent rights. CEN shall not be held responsible for identifying any or all such patent rights.This document supersedes EN 13192:2001.According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Aust
14、ria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spai
15、n, Sweden, Switzerland, Turkey and the United Kingdom.Endorsement noticeThe text of ISO 20486:2017 has been approved by CEN as EN ISO 20486:2018 without any modification.2BS EN ISO 20486:2018ISO 20486:2017Foreword v1 Scope . 12 Normative references 23 Terms and definitions . 24 Nominal leakage rates
16、 35 Classification of leaks 35.1 Permeation leak . 35.2 Conductance leaks . 35.2.1 Capillary leak 35.2.2 Aperture leak (orifice) 45.2.3 Compressed powder leak . 46 Calibration by comparison . 46.1 Methods A, As, B and Bs. 46.2 Applicability of comparison methods . 46.3 Preparation of leaks and appar
17、atus 56.3.1 Leak detector 56.3.2 Connection to the leak detector 56.3.3 Temperature accommodation 76.4 Measurement 76.4.1 Set-up . 76.4.2 General measurement sequence 76.5 Evaluation for methods A, As, B and Bs(Comparison) . 86.5.1 Determination of leakage rate 86.5.2 Influence factors to measuremen
18、t uncertainty . 97 Volumetric calibration.107.1 Direct flow (Method C) 107.1.1 General. 107.1.2 Equipment 107.1.3 Preparation of leaks and apparatus .107.1.4 Measurement . 117.1.5 Evaluation for Method C (direct flow measurement) .137.2 Leak measurement under water (Method D) 147.2.1 General. 147.2.
19、2 Equipment 147.2.3 Preparation of leaks and apparatus .147.2.4 Measurement . 157.2.5 Evaluation for Method D 167.2.6 Influence factors to measurement uncertainty 177.3 Calibration by (volumetric) gas meter (Method E) 177.3.1 General. 177.3.2 Equipment 187.3.3 Preparation of leaks and apparatus .187
20、.3.4 Measurement . 187.3.5 Evaluation for Method E (gas meter) 187.3.6 Influence factors to measurement uncertainty 197.4 Calibration by pressure change in a known volume (Method F) 197.4.1 General. 197.4.2 Preparation of leaks and apparatus .207.4.3 Measurement . 227.4.4 Special situation in vacuum
21、 chambers 237.4.5 Evaluation for Method F (pressure change) 247.4.6 Influence factors to measurement uncertainty 25 ISO 2017 All rights reserved iiiContents PageBS EN ISO 20486:2018ISO 20486:20177.5 Calibration by volume change at constant pressure (Method G) .257.5.1 Equipment 257.5.2 Preparation o
22、f leaks and apparatus .267.5.3 Measurement . 267.5.4 Evaluation for Method G (volume change at constant pressure)278 General influences .289 Report .2810 Labelling of reference leaks .2911 Handling of reference leaks .2911.1 General 2911.2 Permeation leaks (normally with reservoir fitted the leak ou
23、tlet) .2911.3 Conductance leaks (normally without reservoir) 29Annex A (informative) Calculation of leakage rate decrease due to tracer gas depletion in the reservoir 30Bibliography .32iv ISO 2017 All rights reservedBS EN ISO 20486:2018ISO 20486:2017ForewordISO (the International Organization for St
24、andardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the rig
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ENISO204862018ENNONDESTRUCTIVETESTINGLEAKTESTINGCALIBRATIONOFREFERENCELEAKSFORGASESPDF

链接地址:http://www.mydoc123.com/p-726508.html