EN 62305-1-2011 en Protection against lightning - Part 1 General principles《雷电防护 第1部分 一般原则》.pdf
《EN 62305-1-2011 en Protection against lightning - Part 1 General principles《雷电防护 第1部分 一般原则》.pdf》由会员分享,可在线阅读,更多相关《EN 62305-1-2011 en Protection against lightning - Part 1 General principles《雷电防护 第1部分 一般原则》.pdf(74页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwide NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BSI Standards Publication Protection against lightning Part 1: General principles BS EN 62305-1:2011BS EN 62305-1:2011 BRITISH STANDARD National foreword This British Standard is the UK implementation
2、of EN 62305-1:2011. It is identical to IEC 62305-1:2010. It supersedes BS EN 62305-1:2006, which will be withdrawn on 27 May 2012. Parts 1, 3 and 4 of EN 62305 contain references to EN 62305-2:2011. This reference is incorrect since Part 2 is not due to be published until 2012 to allow for the final
3、ization of the CENELEC common modifications. Until EN 62305-2:2012 is published and adopted as BS EN 62305-2:2012, the existing BS EN 62305-2:2006 can continue to be used with the newly published BS EN 62305-1:2011, BS EN 62305-3:2011 and BS EN 62305-4:2011. The UK participation in its preparation w
4、as entrusted to Technical Committee GEL/81, Protection against lightning. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct
5、application. Compliance with a British Standard cannot confer immunity from legal obligations. ISBN 978 0 580 61192 6 ICS 29.020; 91.120.40 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2011. BSI 2011 Amendments and Corrigenda issue
6、d since publication Date Text affected EUROPEAN STANDARD EN 62305-1 NORME EUROPENNE EUROPISCHE NORM February 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue
7、 Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62305-1:2011 E ICS 29.020; 91.120.40 Supersedes EN 62305-1:2006 + corr. Nov.2006English version Protection against lightning - Part 1: General prin
8、ciples (IEC 62305-1:2010, modified) Protection contre la foudre - Partie 1: Principes gnraux (CEI 62305-1:2010, modifie) Blitzschutz - Teil 1: Allgemeine Grundstze (IEC 62305-1:2010, modifiziert) This European Standard was approved by CENELEC on 2011-01-13. CENELEC members are bound to comply with t
9、he CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat
10、or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the offi
11、cial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
12、 Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 62305-1:2011 - 2 - Foreword The text of document 81/370/FDIS, future edition 2 of IEC 62305-1, prepared by IEC TC 81, Lightning protection, was submitted to the IEC-CENELEC parallel vote and was approved by
13、 CENELEC as EN 62305-1 on 2011-01-13. This European Standard supersedes EN 62305-1:2006 + corr. Nov.2006. This EN 62305-1:2011 includes the following significant technical changes with respect to EN 62305-1:2006 + corr. Nov.2006: 1) It no longer covers protection of services connected to structures.
14、 2) Isolated interfaces are introduced as protection measures to reduce failure of electric and electronic systems. 3) First negative impulse current is introduced as a new lightning parameter for calculation purposes. 4) Expected surge overcurrents due to lightning flashes have been more accurately
15、 specified for low voltage power systems and for telecommunication systems. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following
16、 dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-10-13 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-01-13 Annex ZA has been added
17、 by CENELEC. _ Endorsement notice The text of the International Standard IEC 62305-1:2010 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: 1 IEC 60664-1:2007 NOTE Harm
18、onized as EN 60664-1:2007 (not modified). 2 IEC 61000-4-5 NOTE Harmonized as EN 61000-4-5. 7 IEC 61643-1 NOTE Harmonized as EN 61643-11. 8 IEC 61643-21 NOTE Harmonized as EN 61643-21. _ - 3 - EN 62305-1:2011 Annex ZA (normative) Normative references to international publications with their correspon
19、ding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an internati
20、onal publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 62305-2 2010 Protection against lightning - Part 2: Risk management EN 62305-2 2011 IEC 62305-3 2010 Protection against lightning - Part 3: Physical damag
21、e to structures and life hazard EN 62305-3 2011 IEC 62305-4 2010 Protection against lightning - Part 4: Electrical and electronic systems within structures EN 62305-4 2011 2 62305-1 IEC:2010(E) CONTENTS FOREWORD . 5 INTRODUCTION 7 1 Scope . 8 2 Normative references . 8 3 Terms and definitions . 8 4
22、Lightning current parameters 14 5 Damage due to lightning . 14 5.1 Damage to a structure 14 5.1.1 Effects of lightning on a structure 14 5.1.2 Sources and types of damage to a structure . 16 5.2 Types of loss . 16 6 Need and economic justification for lightning protection 18 6.1 Need for lightning p
23、rotection 18 6.2 Economic justification of lightning protection . 19 7 Protection measures. 19 7.1 General 19 7.2 Protection measures to reduce injury of living beings by electric shock . 19 7.3 Protection measures to reduce physical damage 20 7.4 Protection measures to reduce failure of electrical
24、and electronic systems 20 7.5 Protection measures selection 20 8 Basic criteria for protection of structures 21 8.1 General 21 8.2 Lightning protection levels (LPL) 21 8.3 Lightning protection zones (LPZ) 23 8.4 Protection of structures 25 8.4.1 Protection to reduce physical damage and life hazard .
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6230512011ENPROTECTIONAGAINSTLIGHTNINGPART1GENERALPRINCIPLES 雷电 防护 部分 一般 原则 PDF

链接地址:http://www.mydoc123.com/p-721163.html