EN 61643-331-2003 en Components for low-voltage surge protective devices Part 331 Specification for metal oxide varistors (MOV)《低压电涌保护装置用元部件 第331部分 金属氧化物变阻器(MOV)规范 IEC 61643-331 20.pdf
《EN 61643-331-2003 en Components for low-voltage surge protective devices Part 331 Specification for metal oxide varistors (MOV)《低压电涌保护装置用元部件 第331部分 金属氧化物变阻器(MOV)规范 IEC 61643-331 20.pdf》由会员分享,可在线阅读,更多相关《EN 61643-331-2003 en Components for low-voltage surge protective devices Part 331 Specification for metal oxide varistors (MOV)《低压电涌保护装置用元部件 第331部分 金属氧化物变阻器(MOV)规范 IEC 61643-331 20.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 61643-331: 2003 Components for low-voltage surge protective devices Part 331: Specification for metal oxide varistors (MOV) The European Standard EN 61643-331:2003 has the status of a British Standard ICS 31.040 BS EN 61643-331:2003 This British Standard was published under th
2、e authority of the Standards Policy and Strategy Committee on 22 August 2003 BSI 22 August 2003 ISBN 0 580 42491 X National foreword This British Standard is the official English language version of EN 61643-331:2003. It is identical with IEC 61643-331:2003. The UK participation in its preparation w
3、as entrusted by Technical Committee PEL/37, Surge arresters, to Subcommittee PEL/37/2, Surge arresters Low voltage, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which impl
4、ement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication do
5、es not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/Europe
6、an committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, page
7、s 2 to 18, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 61643-331 NORME EUROPENNE EUROPISCHE NORM July 2003 CENELEC European Committ
8、ee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC me
9、mbers. Ref. No. EN 61643-331:2003 E ICS 31.040 English version Components for low-voltage surge protective devices Part 331: Specification for metal oxide varistors (MOV) (IEC 61643-331:2003) Composants pour parafoudres basse tension Partie 331: Spcifications pour les varistances oxyde mtallique (MO
10、V) (CEI 61643-331:2003) Bauelemente fr berspannungsschutzgerte fr Niederspannung Teil 331: Festlegungen fr Metalloxidvaristoren (IEC 61643-331:2003) This European Standard was approved by CENELEC on 2003-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipu
11、late the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standar
12、d exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national
13、 electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lithuania, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. Foreword The text of document 37B/67/FD
14、IS, future edition 1 of IEC 61643-331, prepared by SC 37B, Specific components for surge arresters and surge protective devices, of IEC TC 37, Surge arresters, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61643-331 on 2003-07-01. The following dates were fixed: la
15、test date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2004-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2006-07-01 Annexes designated “normative“ are part of t
16、he body of the standard. In this standard, annexes A and ZA are normative. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61643-331:2003 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliogr
17、aphy, the following notes have to be added for the standards indicated: IEC 60060-1 NOTE Harmonized as HD 588.1 S1:1991 (not modified). IEC 61000-4-5 NOTE Harmonized as EN 61000-4-5:1995 (not modified). IEC 61180-1 NOTE Harmonized as EN 61180-1:1994 (not modified). _ Page2 EN61643331:200361643-331 I
18、EC:2003 3 CONTENTS 1 Scope.4 2 Normative references.4 3 Parametric terms, letter symbols and definitions.5 3.1 Ratings5 3.2 Characteristics6 3.3 Circuit symbol.7 4 Service conditions 7 4.1 Normal service conditions .7 4.2 Abnormal service conditions8 5 Basic function and MOV component description .8
19、 6 Identification.9 6.1 Generalities.9 6.2 Functional and constructive characteristics .9 6.3 Manufacturing inspections.9 7 Marking9 8 Testing and measuring methods.10 8.1 Standard design test criteria10 8.2 Test conditions10 8.3 Ratings10 8.4 Electrical characteristics11 8.5 Dependability12 9 Fault
20、 and failure mode13 9.1 Degradation fault mode .13 9.2 Fault-mode determination of rating test failures.13 Annex A (normative) MOV testing for IEC 61643-1 surge protective devices14 Annex ZA (normative) Normative references to international publications with their corresponding European publications
21、 .17 Bibliography18 Figure 1 V-I characteristic of a MOV 6 Figure 2 Test circuit for impulse peak current clamping voltage (V C ) at peak impulse current (I P ) 10 Figure 3 Test circuit for measuring standby current11 Figure 4 Test circuit for measuring nominal varistor voltage (V N ) .12 Page3 EN61
22、643331:200361643-331 IEC:2003 4 COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES Part 331: Specification for metal oxide varistors (MOV) 1 Scope This part of IEC 61643 is a test specification for metal oxide varistors (MOV), which are used for applications up to 1 000 V a.c. or 1 500 V d.c. in po
23、wer line, or telecommunication, or signalling circuits. They are designed to protect apparatus or personnel, or both, from high transient voltages. This specification applies to MOVs having two electrodes and does not deal with hybrid devices. This specification also does not apply to mountings and
24、their effect on the MOVs characteristics. Characteristics given apply solely to the MOV mounted only in the ways described for the tests. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited app
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN616433312003ENCOMPONENTSFORLOWVOLTAGESURGEPROTECTIVEDEVICESPART331SPECIFICATIONFORMETALOXIDEVARISTORSMOV

链接地址:http://www.mydoc123.com/p-720360.html