EN 61557-2-2007 en Electrical safety in low voltage distribution systems up to 1 000 V a c and 1 500 V d c - Equipment for testing measuring or monitoring of protective measures - .pdf
《EN 61557-2-2007 en Electrical safety in low voltage distribution systems up to 1 000 V a c and 1 500 V d c - Equipment for testing measuring or monitoring of protective measures - .pdf》由会员分享,可在线阅读,更多相关《EN 61557-2-2007 en Electrical safety in low voltage distribution systems up to 1 000 V a c and 1 500 V d c - Equipment for testing measuring or monitoring of protective measures - .pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 61557-2:2007Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Part 2: Insulation resistanceThe European Standard EN 61557-2:2007 has the status of a British StandardICS
2、 17.220.20; 29.080.01; 29.240.01g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61557-2:2007This British Standard was published under the auth
3、ority of the Standards Policy and Strategy Committee on 29 June 2007 BSI 2007ISBN 978 0 580 50861 5National forewordThis British Standard was published by BSI. It is the UK implementation of EN 61557-2:2007. It is identical with IEC 61557-2:2007. It supersedes BS EN 61557-2:1997, which will be withd
4、rawn on 1 March 2010. The UK participation in its preparation was entrusted to Technical Committee PEL/85, Measuring equipment for electrical and electromagnetic quantities.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not pur
5、port to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61557-2 NORME EUROPENNE EUROPIS
6、CHE NORM March 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by
7、 any means reserved worldwide for CENELEC members. Ref. No. EN 61557-2:2007 E ICS 17.220.20; 29.080.01; 29.240.01 Supersedes EN 61557-2:1997English version Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of pr
8、otective measures - Part 2: Insulation resistance (IEC 61557-2:2007) Scurit lectrique dans les rseaux de distribution basse tension de 1 000 V c.a. et 1 500 V. c.c. - Dispositifs de contrle, de mesure ou de surveillance de mesures de protection - Partie 2: Rsistance disolement (CEI 61557-2:2007) Ele
9、ktrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V - Gerte zum Prfen, Messen oder berwachen von Schutzmanahmen - Teil 2: Isolationswiderstand (IEC 61557-2:2007) This European Standard was approved by CENELEC on 2007-03-01. CENELEC members are bound to comply with the CEN/CENE
10、LEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any C
11、ENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versio
12、ns. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania,
13、Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 85/291/FDIS, future edition 2 of IEC 61557-2, prepared by IEC TC 85, Measuring equipment for electrical and electromagnetic quantities, was submitted to the IEC-CENELEC parallel vote and was approved
14、 by CENELEC as EN 61557-2 on 2007-03-01. This European Standard supersedes EN 61557-2:1997. The following changes were made with respect to EN 61557-2:1997: definitions complemented; revision of some requirements; addition of a warning pictogram; complete revision of the subclause on overload tests.
15、 This standard is to be used in conjunction with EN 61557-1. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-12-01 latest date by which the national standards conflicting
16、 with the EN have to be withdrawn (dow) 2010-03-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61557-2:2007 was approved by CENELEC as a European Standard without any modification. _ EN 61557-2:2007 2 CONTENTS 1 Scope.4 2 Normative references4
17、3 Terms and definitions .4 4 Requirements .4 5 Marking and operating instructions6 5.1 Marking .6 5.2 Operating instructions6 6 Tests 6Annex ZA (normative) Normative references to international publications with theircorresponding European publications.9 Table 1 Calculation of operating uncertainty
18、.5EN 61557-2:2007 3 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 000 V a.c. AND 1 500 V d.c. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES Part 2: Insulation resistance 1 Scope This part of IEC 61557 specifies the requirements applicable to equipment for meas
19、uring the insulation resistance of equipment and installations in the de-energized state. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition
20、 of the referenced document (including any amendments) applies. IEC 61010-1:2001, Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements IEC 61557-1, Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d
21、.c. Equipment for testing, measuring or monitoring of protective measures Part 1: General requirements 3 Terms and definitions For the purposes of this document, the definitions given in IEC 61557-1 and the following definitions apply. 3.1 rated output voltage UNvoltage output across the measuring e
22、quipment terminals when this equipment is loaded with the rated current 4 Requirements The following requirements as well as those given in IEC 61557-1 shall apply. 4.1 The output voltage shall be a d.c. voltage; the indication at the rated output voltage across a resistor of a value of UN (1 000 /V
23、) shall not differ by more than 10 % relative to the indicated value, as a result of possibly present a.c. voltage components in the output voltage, when a capacitor of 2 F is connected in parallel with the insulation resistance to be measured. 4.2 The open-circuit voltage shall not exceed 1,25 time
24、s the rated output voltage. 4.3 The rated current shall be at least 1 mA. EN 61557-2:2007 4 4.4 The measuring current shall not exceed 15 mA peak. Any a.c. component present shall not exceed 1,5 mA peak. 4.5 The maximum percentage operating uncertainty within the measurement range to be marked or st
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6155722007ENELECTRICALSAFETYINLOWVOLTAGEDISTRIBUTIONSYSTEMSUPTO1000VACAND1500VDCEQUIPMENTFORTESTINGMEASURINGORMONITORINGOFPROTECTIVEMEASURESPDF

链接地址:http://www.mydoc123.com/p-720280.html