EN 61290-4-3-2015 en Optical amplifiers - Test methods - Part 4-3 Power transient parameters - Single channel optical amplifiers in output power control.pdf
《EN 61290-4-3-2015 en Optical amplifiers - Test methods - Part 4-3 Power transient parameters - Single channel optical amplifiers in output power control.pdf》由会员分享,可在线阅读,更多相关《EN 61290-4-3-2015 en Optical amplifiers - Test methods - Part 4-3 Power transient parameters - Single channel optical amplifiers in output power control.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationOptical amplifiers Test methodsPart 4-3: Power transient parameters -Single channel optical amplifiers inoutput power controlBS EN 61290-4-3:2015National forewordThis British Standard is the UK implementation of EN 61290-4-3:2015. It isidentical to IEC 61290-4-3:2015.The UK
2、participation in its preparation was entrusted by TechnicalCommittee GEL/86, Fibre optics, to Subcommittee GEL/86/3, Fibre optic systems and active devices.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include al
3、l the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 83188 1ICS 33.180.30Compliance with a British Standard cannot confer immunity fromlegal obligations.This British St
4、andard was published under the authority of theStandards Policy and Strategy Committee on 30 November 2015.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 61290-4-3:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61290-4-3 November 2015 ICS 33.180.30 En
5、glish Version Optical amplifiers - Test methods - Part 4-3: Power transient parameters - Single channel optical amplifiers in output power control (IEC 61290-4-3:2015) Amplificateurs optiques - Mthodes dessai - Partie 4-3: Paramtres de puissance transitoire - Contrle de la puissance de sortie des am
6、plificateurs optiques monocanaux (IEC 61290-4-3:2015) Optische Verstrker - Prfverfahren - Teil 4-3: Leistungs-Transientenkenngren von Ein-Kanal-LWL-Verstrkern mit Ausgangs-Leistungskontrolle (IEC 61290-4-3:2015) This European Standard was approved by CENELEC on 2015-06-09. CENELEC members are bound
7、to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-
8、CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Ce
9、ntre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, It
10、aly, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr
11、 Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61290-4-3:2015 E BS EN 61290-4-3:2015EN 61290-4-3:2015 2 European foreword The text of
12、document 86C/1310/FDIS, future edition 1 of IEC 61290-4-3, prepared by SC 86C “Fibre optic systems and active devices“ of IEC/TC 86 “Fibre optics“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61290-4-3:2015. The following dates are fixed: latest date by which the docu
13、ment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2016-05-20 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-06-09 This standard is to be used in conjunction with EN 61290-1:
14、2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61290-4-3:2015 was
15、 approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 61290-3-3 NOTE Harmonized as EN 61290-3-3. IEC 61290-4-1 NOTE Harmonized as EN 61290-4-1. BS EN 61290-4-3:2015EN 6129
16、0-4-3:2015 3 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edit
17、ion cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest
18、 versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 61291-1 2012 Optical amplifiers - Part 1: Generic specification EN 61291-1 2012 BS EN 61290-4-3:2015 2 IEC 61290-4-3:2015 IEC 2015 CONTENTS FOREWORD . 3 1 Scope 5 2 Norma
19、tive references 5 3 Terms, definitions and abbreviations . 6 3.1 Terms and definitions 6 3.2 Abbreviations 7 4 Apparatus 7 4.1 Test set-up . 7 4.2 Characteristics of test equipment 8 5 Test sample . 9 6 Procedure 9 6.1 Test preparation 9 6.2 Test conditions . 9 7 Calculations . 10 8 Test results . 1
20、1 8.1 Test settings . 11 8.2 Test data 12 Annex A (informative) Overview of power transient events in single channel EDFA 13 A.1 Background. 13 A.2 Characteristic input power behaviour 13 A.3 Parameters for characterizing transient behaviour 15 Annex B (informative) Background on power transient phe
21、nomena in a single channel EDFA 17 B.1 Amplifier chains in optical networks 17 B.2 Typical optical amplifier design . 17 B.3 Approaches to address detection errors 19 Annex C (informative) Slew rate effect on transient gain response . 23 Bibliography 24 Figure 1 Power transient test set-up. 8 Figure
22、 2 OA output power transient response of a) input power increase . 11 Figure A.1 Example OA input power transient cases for a receiver application . 14 Figure A.2 Input power measurement parameters for a) input power increase and b) input power decrease 15 Figure A.3 OA output power transient respon
23、se of a) input power increase and b) input power decrease 16 Figure B.1 Transient response to a) input power drop (inverse step transient) with transient control, b) deactivated (constant pump power), and c) activated (power control) 21 Figure B.2 Transient response to a) input power rise (step tran
24、sient) with transient control, b) deactivated (constant pump power), and c) activated (power control) . 22 Table 1 Examples of transient control measurement test conditions . 10 BS EN 61290-4-3:2015IEC 61290-4-3:2015 IEC 2015 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ OPTICAL AMPLIFIERS TEST METH
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN61290432015ENOPTICALAMPLIFIERSTESTMETHODSPART43POWERTRANSIENTPARAMETERSSINGLECHANNELOPTICALAMPLIFIERSINOUTPUTPOWERCONTROLPDF

链接地址:http://www.mydoc123.com/p-719945.html