EN 61041-5-1997 en Non-Broadcast Video Tape Recorders - Methods of Measurement Part 5 High-Band Video Tape Recorders Including Those Equipped with Y C Video Connectors (NTSC PAL)《非.pdf
《EN 61041-5-1997 en Non-Broadcast Video Tape Recorders - Methods of Measurement Part 5 High-Band Video Tape Recorders Including Those Equipped with Y C Video Connectors (NTSC PAL)《非.pdf》由会员分享,可在线阅读,更多相关《EN 61041-5-1997 en Non-Broadcast Video Tape Recorders - Methods of Measurement Part 5 High-Band Video Tape Recorders Including Those Equipped with Y C Video Connectors (NTSC PAL)《非.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、- STDaBSI BS EN 61041-5-ENGL 1998 D 1b24bb9 Ob92498 52T BRITISH STANDARD Methods of measurement Non-broadcast video -tape recorders Part 5. High-band video tape recorders, including those equipped with Y/C video connectors (NTSC/PAL) * VI * The European Standard EN 61041-5 : 1997 has the status of a
2、 British Standard ICs 33.160.40 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN BS 7434 : Part 5 : 1998 IEC 61041-5 : 1997 61041-5 : 1998 STD-BSI BS EN b1041-5-ENGL 1998 1624669 0692499 4bb BS EN 61041-5 : 1998 Amd. No. National foreword Date Text affected This British S
3、tandard is the English language version of EN 61041-5 : 1997. It is identical with IEC 61041-5 : 1997. The K participation in its preparation was entrusted by Technical Committee EPU100, Audio,video and multimedia systems and equipment, to Subcommittee EPU100/2, Recording, which has the responsibili
4、ty to: - aid enquirers to understand the text; - present to the responsible internationalEuropean committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; - monitor related international and European developments and promulgate them in the UK This B
5、ritish Standard, having been prepared under the direction of the Eie therefore, these methods apply to measurement of the signal around those frequencies. 1.4.5 waveform distortion in vertical direction of a picture screen: Picture distortion in vertical direction of a picture screen caused by horiz
6、ontal (line) correlation process with a comb filter. It is measured as waveform distortion of luminance signal. 1.4.6 colour flicker: Flicker resulting from amplitude and phase variations of the chrominance signal from field to field. 1.4.7 colour change points: Transition points where the hue and/o
7、r level of the chrominance signal changes in the horizontal direction of a picture screen. 1.4.8 colour displacement in vertical direction: Time delay of the chrominance signal with respect to the luminance signal. It is measured as the number of horizontal lines. 1.4.9 colour distortion in vertical
8、 direction: Rise and fall time periods of the chrominance signal in the vertical direction. It is measured as the number of horizontal lines. 1.4.1 O Y signal: Abbreviated expression for luminance signal. 1.4.1 1 C signal: Abbreviation for chrominance signal. It is the colour subcarrier of the NTSC
9、or PAL system modulated by the chrominance signal. Section 2: Video characteristics, luminance signal (NTSWPAL) 2.1 Luminance signal-to-noise ratio This is the ratio of the reference voltage level (100 % level is 0,714 Vp-p for NTSC and 0,700 Vp-p for PAL) of the video test signal, with respect to t
10、he r.m.s. voltage level of noise at a flat part of the waveform of the luminance signal. 2.1.1 Test signal The test signal shall be as follows: a) for composite video input connector, see figure 1 ; b) for S video input connector, see figures 2 and 3. 2.1.2 Block diagram The block diagram for measur
11、ement shall be as follows: a) for composite video input connector, see figure 4; b) for S video input connector, see figure 5. STDeESI ES EN bL041-5-ENGL 5998 m Lb24669 Ob92509 135 m Page 10 EN 61041-6 : 1997 LPF sc trap Weight 2.1.3 Measurement 6 MHz 6 MHz On off off off - For a video tape recorder
12、 equipped with a composite video connector, the composite video test signal shall be as shown in figure 1. For a video tape recorder equipped with an S video connector, the S luminance and S chrominance test signals shall be as shown in figures 2 and 3. Then, using a colour noise meter, measure the
13、signal-to-noise ratio of the luminance signal. The following table lists the setting for the colour noise meter. a) Set the colour noise meter as follows: Table 1 - Setting of colour noise meter 1 I mmsitevideo sianai I S video sional I I HPF I 100 kHz I 100 kHz I b) Adjust the input level to 0,357
14、V for NTSC; 0,350 V for PAL. c) Read the colour noise meter. 2.1.4 Presentation of the results Presentation of the results shall be as follows: - the composite video connector: dB - the S video connector: dB 2.2 Horizontal resolution This is the resolution in the horizontal direction of a picture sc
15、reen. Toobtain the resolution, refer to the frequency where the test signal decreases a specified amount by recording and reproducing the resolution test signal of the luminance signal. 2.2.1 Test signal The test signal shall be a frequency sweep signal (synchronized with vertical sync signal) with
16、markers. The range or the frequency sweep shall be 100 kHz to 8 MHt. a) For composite video input connector, see figure 6. b) For S video input connector: - S luminance signal: use only the luminance portion of the test signal shown in figure 6; - S chrominance signal: use only the colour burst of t
17、he test signal shown in figure 6. 2.2.2 Block diagram The block diagram for measurement shall be as follows: a) for composite video input connector, see figure 7; b) for S video input connector, see figure 8. * * IB STD.BSI BS EN bL041-5-ENGL 1996 Lb24669 Ob925LO 957 Page 11 EN 61041-5 : 1997 2.2.3
18、Measurement Record and reproduce the frequency sweep test signal and read the frequency where the output level is 28,6 mV for NTSC; 28,O mV for PAL, which is -20 dB with respect to 40 % level. Use the following equation to obtain the horizontal resolution: Resolution s W x 2(1- a) f, / f, = 80 x f,
19、(TV line) where f, is the horizontal scanning frequency (MHz); a is the ratio of the blanking period in the horizontal scanning period (0,1700 for NTSC, 0,1875 for PAL); fo is the frequency (MHz) where the output signal level is 28,6 mV for NTSC; 28,O mV for PAL. NOTE - If the output signal contains
20、 too much noise and its level cannot be read clearly, apply single frequencies from within the normal sweep signal, one after another. Then, find the frequency at which the signal level reads 28,6 mV for NTSC or 28,O mV for PAL. 2.2.4 Presentation of results Presentation of the results shall be as f
21、ollows: - for the composite video signal: TV lines - for the S video signal: TV lines 2.3 Vertically correlated waveform distortion (waveform distortion of vertical This is to be measured as reproducibility of the waveform of vertical pulses when recording and reproducing the test signal for wavefor
22、m distortion measurement. luminance signal) 2.3.1 Test signal The test signal shall be as follows: a) for composite video input connector, see figure 9; b) for S video input connector: - S luminance signal: use only the luminance portion of the test signal shown in figure 9; - S chrominance signal:
23、use only the colour burst signal of the test signal shown in figure 9. NOTE - A window signal can be substituted for measurement of overshoot, pre-shoot, smear, and rise and fall time periods. 2.3.2 Block diagram The block diagram for measurement shall be as follows: a) for composite video input con
24、nector, see figure 7; b) for S video input connector, see figure 8. - STD.BSI BS EN 61041-5-ENGL 1998 Lb24669 0692511 893 Page 12 EN 61041-6 : 1997 Overshoot 2.3.3 Measurement Record and reproduce the test signal, and observe the output signal following items shall be measured. See figures 10, 11, 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6104151997ENNONBROADCASTVIDEOTAPERECORDERSMETHODSOFMEASUREMENTPART5HIGHBANDVIDEOTAPERECORDERSINCLUDINGTHOSEEQUIPPEDWITHYCVIDEOCONNECTORSNTSCPAL

链接地址:http://www.mydoc123.com/p-719383.html