EN 60146-1-3-1993 en Semiconductor Convertors General Requirements and Line Commutated Convertors Part 1-3 Transformers and Reactors (Remains Current)《半导体变流器 一般要求和电网换相转换器 第1-3部分 变压.pdf
《EN 60146-1-3-1993 en Semiconductor Convertors General Requirements and Line Commutated Convertors Part 1-3 Transformers and Reactors (Remains Current)《半导体变流器 一般要求和电网换相转换器 第1-3部分 变压.pdf》由会员分享,可在线阅读,更多相关《EN 60146-1-3-1993 en Semiconductor Convertors General Requirements and Line Commutated Convertors Part 1-3 Transformers and Reactors (Remains Current)《半导体变流器 一般要求和电网换相转换器 第1-3部分 变压.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、= 3404583 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM 0057bql1 O50 = EN 60146-1-3 February 1993 UDC 621.314.21 : 621.315.59 : 621.318 Descriptors: Electronics, convertors, semiconductor convertors, tranformers, reactors, characteristics, specifications, test English version Semiconductor conve
2、rtors General requirements and line commutated convertors Part 1-3: Transformers and reactors (IEC 146-1-3 : 1991) Convertisseurs semiconducteurs Halbleiter-Stromrichter Spcifications communes et convertisseurs commuts par le rseau Stromrichter Partie 1-3: Transformateurs et bobines Allgemeine Anfor
3、derungen und netzgefhrte Ri1 1-3: Transformatoren und Drosselspulen dinductance (IEC 146-1-3 : 1991) (CE1 146-1-3 : 1991) This European Standard was approved by CENELEC on 1992-12-09. CENELEC members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for givi
4、ng this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official v
5、ersions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees
6、 of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisc
7、hes Komitee fr Elektrotechnische Normung Centrai Secretariat: rue de Stassart 36, B-1050 Brussels O 1993 Copyright reserved to CENELEC members Ref. No. EN 60146-1-3 : 1993 E Page 2 EN 60146-11-3 : 1993 Foreword The CENELEC questionnaire procedure, performed for finding out whether or not the Interna
8、tional Standard IEC 146-1-3 : 1991 could be accepted without textual changes, has shown that no common modifications were necessary for the acceptance as European Standard. The reference document was submitted to the CENELEC members for formal vote and was approved by CENELEC as EN 60146-1-3 on 9 De
9、cember 1992. The following dates were fixed, - latest date of publication of an identical national standard (dop) 1993-12-01 - latest date of withdrawa of conflicting national standards (dw) 1993-12-01 For products which have complied with the relevant national standard before 1993-12-01, as shown b
10、y the manufacturer or by a certification body, this previous standard may continue to apply for production until 1998-12-01. Annexes designated ?normative? are part of the body of the standard. In this standard, annexes A and ZA are normative. = 3404583 0057b93 923 Page 3 EN 60146-1-3 : 1993 CONTENT
11、S clause 1 Scope . 2 Normative references . 3 Rated values for convertor transformers . 3.1 Rated current values . 3.2 Temperature limits of cooling media . 4 Losses and voltage drops in transformers and reactors . 4.1 Losses in the transformer windings . 4.2 Losses in interphase transformers. curre
12、nt balancing reactors. ser- ies-smoothing reactors. transductors and other current regulating acces- sories . 4.3 Voltage drops in transformers and reactors 5 Tests for convertor transformers 5.1 Measurement of commutating reactance and determination of inductive voltage drop (type test) . 5.2 Short
13、-circuit test (type test and routine test) . 5.3 Temperature rise test (type test) . Annex A (normative) . Corrections to be applied when cooling medium temperature is higher than standard Annex ZA (normative) Other international publications quoted in this standard with the references of the releva
14、nt European publications . Tables 1 . Temperature rise limits 2 . Connections and calculation factors . Page 4 4 5 5 5 6 6 6 7 7 7 8 9 13 13 14 10 11 W 3404583 005b4 8bT = Page 4 EN 60146-1-3 : 1993 SEMICONDUCTOR CONVERTORS General requirements and line commutated convertors Part 1-3: Transformers a
15、nd reactors 1 Scope This Part 1-3 of the International Standard relates, in general, to those characteristics wherein convertor transformers differ from ordinary power transformers. In all other respects, the rules spedfied in IEC 76 shall apply to convertor transformers. also, as far as they are no
16、t in contradiction with this standard. It should be borne in mind that a rectifier transformer operates with non-sinusoidal current waveshape. In single-way connection, the current in each cell winding contains a d.c. component which calls for special attention in design and testing. In some cases,
17、a special design is necessary when external short-circuits and cell failures would cause abnormal stress. For certain types of transformers, the waveshape of the normal operating voltage is non-sinusoidal. The core loss of such equipment is to be determined by applying a sinu- soidal voltage having
18、the same half-cyde arithmetic mean value and the same fundamental frequency as the voltage applied in service. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publication, th
19、e editions indicated were valid. All standards are subject to revision, and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the standards listed below. Members of IEC and IS0 maintain registers of curren
20、tly valid International Standards. IEC 76: 1967, Power transformem. IEC 146-1-1 : 1991, Semiconductor convettom - General requirements and line commutated convertors - Part 1-1, IEC 146-1 -1. Specifications of basic requirements. IEC 146-1 -2: 1991, Semiconductor convemrs - General requirements and
21、ine commutated convertors - Part 1-2: Application guide. m 3404583 0057675 7Tb m Fge 5 EN 60146-1-3 : 1993 3 Rated values for convertor transformers 3.1 Rafed current values 3.1.1 Single convertor or double convertor supplied from one common cell winding The convertor transformer shall be capable of
22、 cartying current corresponding to rated direct current of the convertor continuously, followed by overload current (where specified) for the specified duration (See IEC 146-1 -1, 3.1 0.3.5), at maximum cooling temperatures without exceeding its thermal limit. 3.1.2 Double Convertor where each fhyri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN60146131993ENSEMICONDUCTORCONVERTORSGENERALREQUIREMENTSANDLINECOMMUTATEDCONVERTORSPART13TRANSFORMERSANDREACTORSREMAINSCURRENT

链接地址:http://www.mydoc123.com/p-717659.html