EN 50464-4-2007 en Three-phase oil-immersed distribution transformers 50 Hz from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 4 Requirements an.pdf
《EN 50464-4-2007 en Three-phase oil-immersed distribution transformers 50 Hz from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 4 Requirements an.pdf》由会员分享,可在线阅读,更多相关《EN 50464-4-2007 en Three-phase oil-immersed distribution transformers 50 Hz from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 4 Requirements an.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 50464-4:2007Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV Part 4: Requirements and tests concerning pressurised corrugated tanksICS 29.180nullnull nullnullnullnullnullnullnull nullnulln
2、ullnullnullnullnull nullnullnull nullnullnullnullnullnullnullnullnullnull nullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnullnull+A1:2011National forewordThis British Standard is the UK implementation of EN 50464-4:2007+A1:201
3、1. It supersedes BS EN 50464-4:2007 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee PEL/14, Power transformers.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to includ
4、e all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 50464-4:2007+A1:2011This British Standard waspublished under the authorityof the Standards Policy andStrategy Committ
5、eeon 31 August 2007 BSI 2011Amendments/corrigenda issued since publicationDate Comments 31 December 2011 Implementation of CENELEC amendment A1:2011: additional text in subclause 3.1ISBN 978 0 580 75264 3EUROPEAN STANDARD EN 50464-4:2007+A1NORME EUROPENNE EUROPISCHE NORMCENELEC European Committee fo
6、r Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELECAll rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Re
7、f. No. EN 50464-4:2007 EEnglish version Three-phase oil-immersed distribution transformers50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV -Part 4: Requirements and tests concerning pressurised corrugated tanks Transformateurs triphass de distribution immergs da
8、ns lhuile,50 Hz, de 50 kVA 2 500 kVA,de tension la plus leve pour le matriel ne dpassant pas 36 kV - Partie 4: Prescriptions et essais relatifsaux cuves sous pression lgefllte Drehstrom-Verteilungstransformatoren 50 Hz, 50 kVA bis 2 500 kVAmit einer hchsten Spannung fr Betriebsmittel bis 36 kV - Tei
9、l 4: Anforderungen und Prfungen fr druckbeanspruchte Wellwandkessel This European Standard wasapproved by CENELEC on 2006-12-01. CENELEC members are bound tocomplywiththe CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standa
10、rd without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version inanyotherlang
11、uage made by translation under the responsibility of a CENELEC member into its own languageand notified to the Central Secretariat has the same status as the official versions.CENELECmembersare the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic,Denmark
12、, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia,Slovenia, Spain, Sweden, Switzerland and the United Kingdom.ICS 29.180 Supersedes HD 428.6 S1:2002October 2011 2 Foreword T
13、he text of the Harmonization Document HD 428.6 S1:2002, prepared by the Technical Comm ittee CENELEC TC14, Power transformers, was submitted to the formal vote for conversion into a European Standard and was approved by CENELEC as EN 50464-4 on 2006-12-01.The following date was fixed: latest date by
14、 which the EN has to be implemented at national level by publication of an identicalnational standard or by endorsement (dop) 2007-12-01 The EN50464 seriesconsistsofthe following parts, under the general title “Three-phase oil-immersed distribution transformers 50 Hz,from 50 kVA to 2 500 kVA with hi
15、ghest voltage for equipment notexceeding 36 kV”:Part 1 General requirementsPart2-1 Distribution transformers with cable boxes on the high-voltage and/or low-voltage side General requirementsPart2-2 Distribution transformers with cable boxes on the high-voltage and/or low-voltage side Cable boxes typ
16、e 1 for use on distribution transformers meeting the requirements of EN 50464-2-1 Part2-3 Distribution transformers with cable boxes on the high-voltage and/or low-voltage side Cable boxes type 2 for use on distribution transformers meeting the requirements of EN 50464-2-1 Part 3 Determination of th
17、e power rating of a transformer loaded with non-sinusoidalcurrents Part 4 Requirements and tests concerning pressurised corrugated tanksThis document (EN 50464-4:2007/A1:2011) has been prepared by the CLC/TC 14, “Power transformers“. The following dates are fixed: latest date by which the document h
18、as to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-10-10 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2014-10-10 Attention is drawn to the possibility that some of the elements o
19、f this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. _ Foreword to amendment A1 BS EN 50464-4:2007+A1:2011 EN 50464-4:2007+A1:2011 (E) 3 Content1Scope42Normative references43General conditions43.1Temperat
20、ure variation43.2Sealing temperature.43.3Calculation of the volume variation44Test procedure.44.1General.44.2Measurement of pressure range.44.3Endurance test54.4Leakage test.54.5Evaluation of the tests.5BS EN 50464-4:2007+A1:2011 EN 50464-4:2007+A1:2011 (E) 4 1 Scope This Part 4 of EN 50464 series i
21、s applicable to testprocedures to verify the mechanicalwithstand capability of the corrugated tanks of completely oil filled and hermetically sealed distribution transformers.NOTE Variations of oil temperature due to variations of ambient temperature and loading, result in deformation of tank walls.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN5046442007ENTHREEPHASEOILIMMERSEDDISTRIBUTIONTRANSFORMERS50HZFROM50KVATO2500KVAWITHHIGHESTVOLTAGEFOREQUIPMENTNOTEXCEEDING36KVPART4REQUIREMENTSANPDF

链接地址:http://www.mydoc123.com/p-717175.html