《EN 50075-1990 en Flat Non-Wirable Two-Pole Plugs 2 5 A 250 V with Cord for the Connection of Class II-Equipment for Household and Similar Purposes《家用和类似用途Ⅱ类设备连接用带软线的2 5A、250V非线材制造的.pdf》由会员分享,可在线阅读,更多相关《EN 50075-1990 en Flat Non-Wirable Two-Pole Plugs 2 5 A 250 V with Cord for the Connection of Class II-Equipment for Household and Similar Purposes《家用和类似用途Ⅱ类设备连接用带软线的2 5A、250V非线材制造的.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、STD-BSI BS EN 50075-ENGL 1991 9 Lb2qbb9 079817L TI7 BRITISH STANDARD Specification for Flat non-wirable two-pole plugs, 2,5 A 250V, with cord, for the connection of class II-equipment for household and similar purposes The European Standard EN 50075 : 1990 has the status of a British Standard ICs 29
2、.120.30 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPRIGH LAW BS EN 50075 : 1991 ncorpomting Corrigendum No. 1 - STD=BSI BS EN 50075-ENGL 1991 I Lb2qbbS 0778172 773 loSi9 s after application of the voltage. The insulation resistance shall be not less than 5 m. The insulation resistanc
3、e is measured consecutively between: - the pins connected together and the body; - each pin in turn and the other, the latter being connected to the body. The term “body“ means a metal foil in contact with the outer surface of the plug, other than the engagement face and the insulating sleeves. Whil
4、e wrapping the metal foil round the outer surface, it is pressed against holes or grooves without any appreciable force by means of the straight unjointed test fmger, having the same dimensions as the standard test finger shown in figure 3. 11.2 A voltage of substantially sine-wave form, having a fr
5、equency of 50 Hz, is applied for 1 min between the parts indicated in 11.1 . The test voltage shall be 2000 v. Initially, not more than 1000 V is applied, then it is raised rapidly to the full 2000 V. No flashover or breakdown shall occur during the test. The high-voltage transformer used for the te
6、st shall be so designed that, when the output terminals are short-circuited after the output voltage has been adjusted to the appropriate test voltage, the output current is at least 200 mA. The overcurrent relay shall not trip when the output current is less than 100 mA. Care is taken that the r.m.
7、6. value of the test voltage applied is measured within f 3 %. Glow discharges without drop in voltage are neglected. STD*BSI BS EN 50075-ENGL 1991 W LbZlibbS 0798179 228 Page 6 EN 80075 : 1990 12 Flexible cords and their connection 12.1 Plugs shall be provided with a two-core cord complying with ei
8、ther HD 21.5 or HD 22.4. Flat tinsel cords and cords having a cross-sectional area of 0,5 mm2 are allowed in lengths up to 2 m only. A plug incorporated in a cord set is tested as specified in this standard and the connector is tested as specified in EN 60320, each device being tested individually.
9、Compliance is checked by inspection. 12.2 Moulded-on plugs shall be so designed that the cores of the cord are relieved from strain where they are connected to the terminations. Plugs other than moulded-on plugs, shall be provided with a cord anchorage such that the cores of the cord are relieved fr
10、om strain, including twisting, where they are connected to the terminations and that their insulation is protected from abrasion. The sheath, if any, of the cord shall be clamped within the cord anchorage. Compliance is checked by inspection and by the following test, made on new plugs of the second
11、 set. The plug is placed in a test apparatus as shown in figure 5 so that the axis of the cord is vertical where it enters the plug. The cord is then subjected 100 times to a pull of 50 N. The pulls are applied practically without jerks each time for 1 s. Immediately afterwards the cord is subjected
12、 for 1 min to a torque of - 0,l Nm if the cord connected has a nominal cross- sectional area of 0,5 mm2 - O, 15 Nm if the cord connected has a nominal cross-sectional area of 0,75 mm2 or more. Plugs with flat tinsel cords H03VH-Y are not subjected to this torque test. After the test, the cord shall
13、not have been displaced by more than 2 mm and there shall be no break in the electrical connections. For the measurement of the longitudinal displacement, a mark is made on the cord while it is subjected to the pull, at a distance approximately 2 cm from the end of the plug, before starting the test
14、s. If, for moulded-on plugs, there is no definite end to the plug, an additional mark is made on the body of the plug. After the tests, the displacement of the mark on the cord in relation to the plug, or to the mark on the plug, is measured while the cord is subjected to the pull. 12.3 Plugs shall
15、be so designed that the cord is protected against excessive bending where it enters the plug. Guards provided for this purpose shall be of insulating material and shall be fixed in a reliable manner. Helical metal springs, whether bare or covered with insulating material, shall not be used as cord g
16、uards. Compliance is checked by inspection and by a flexing test in an apparatus having an oscillating member similar to that shown in figure 6. The test is made on plugs of the third set. The plug is fixed to the oscillating member of the apparatus so that, when this is at the middle of its travel,
17、 the axis of the cord where it enters the plug, is vertical and passes through the axis of oscillation. Plugs with flat cords are mounted so that the major axis of the section is parallel to the axis of oscillation. The plug shall be xed in the test apparatus by its pins. The distance between the co
18、rd entry of the plug and the axis of oscillation is adjusted so that the weight makes the minimum lateral movement as the oscillating member moves over its fi111 travel. The cord is loaded with a mass so that the force applied is: - 10 N for plugs with cords having a nominal mss- sectional area of 0
19、,75 mm2 or less, - 20 N for plugs with other cords. A current of (2,5$42) A is passed through the conductors, the voltage between them being (250 f 15) V a.c. The oscillating member is moved backwards and forwards through an angle of 90“ (45“ on either side of the vertical), the number of flexings b
20、eing i0 O00 and the rate of flexing 60 per minute. A flexing is one movement, either backwards or forwards. Plugs with circular-section cords are turned through Wo in the oscillating member after 5 O00 flexings; plugs with flat cords are only bent in a direction perpendicular to the plane containing
21、 the axis of the cores. During the test, there shall be no interruption of the test current and no short-circuit between conductors. After the test, the plugs shall show no damage within the meaning of this standard, a guard, if any, shall not have separated from the body and the insulation of the c
22、ord shall show no sign of abrasion or wear and broken strands of the conductors shall not have pierced the insulation so as to become accessible. A short-circuit between the conductors of the cord is considered to occur if the current attains a value of 5 A. The voltage drop between a pin and the co
23、rresponding conductor shall not exceed 10 mV, when measured with a test current of: (l+$l) A for plugs with flat tinsel cord HOSVH-Y (2,5 T2) A for plugs with another cord. 13 Mechanicalstrength Plugs shall have adequate mechanical strength to withstand the stresses imposed during use. Compliance is
24、 checked by the tests of 13.1 and 13.4. 13.1 The plugs are pressed between two flat surfaces with a force of 150 N for 5 min, as shown in figure 7. Fifteen minutes after removal of the force, the plug shall not show such deformation as would result in undue alteration of those dimensions shown in St
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN500751990ENFLATNONWIRABLETWOPOLEPLUGS25A250VWITHCORDFORTHECONNECTIONOFCLASSIIEQUIPMENTFORHOUSEHOLDANDSIMILARPURPOSES

链接地址:http://www.mydoc123.com/p-716624.html