EN 15111-2007 en Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry)《食品 微量元素的测定 ICP-MS(感应耦合等离子体质谱分析法)测定碘.pdf
《EN 15111-2007 en Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry)《食品 微量元素的测定 ICP-MS(感应耦合等离子体质谱分析法)测定碘.pdf》由会员分享,可在线阅读,更多相关《EN 15111-2007 en Foodstuffs - Determination of trace elements - Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry)《食品 微量元素的测定 ICP-MS(感应耦合等离子体质谱分析法)测定碘.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 15111:2007Foodstuffs Determination of trace elements Determination of iodine by ICP-MS (inductively coupled plasma mass spectrometry)The European Standard EN 15111:2007 has the status of a British StandardICS 67.050g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44
2、g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 15111:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2007 BSI 2007ISBN 978 0 580 5048
3、5 3National forewordThis British Standard was published by BSI. It is the UK implementation of EN 15111:2007. It supersedes DD CEN/TS 15111:2005 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee AW/-/3, Food analysis Horizontal methods.A list of organiza
4、tions represented on AW/-/3 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. Amendme
5、nts issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15111March 2007ICS 67.050 Supersedes CEN/TS 15111:2005 English VersionFoodstuffs - Determination of trace elements - Determination ofiodine by ICP-MS (inductively coupled plasma massspectrometry)Produ
6、its alimentaires - Dosage des lments traces -Dosage de liode par spectromtrie dmission avec plasmainduit par haute frquence et spectromtre de masse (ICP-SM)Lebensmittel - Bestimmung von Elementspuren -Bestimmung von Iod mit der ICP-MS(Massenspektrometrie mit induktiv gekoppeltem Plasma)This European
7、 Standard was approved by CEN on 21 January 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concern
8、ing such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own lan
9、guage and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Lux
10、embourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All right
11、s of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15111:2007: EEN 15111:2007 (E) 2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Principle4 4 Reagents.4 5 Apparatus and equipment 6 6 Sampling.7 7 Procedure .7 8 Calculation9 9 Limit o
12、f quantification .9 10 Precision.9 11 Test report 10 Annex A (normative) Results of the inter-laboratory test.11 Bibliography 12 EN 15111:2007 (E) 3 Foreword This document (EN 15111:2007) has been prepared by Technical Committee CEN/TC 275 “Food analysis - Horizontal methods”, the secretariat of whi
13、ch is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2007, and conflicting national standards shall be withdrawn at the latest by September 2007. This document supersedes C
14、EN/TS 15111:2005. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland
15、, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 15111:2007 (E) 4 1 Scope This European Standard specifies an extraction method for the determination of iodine compounds in fo
16、odstuffs by inductively coupled plasma mass spectrometry (ICP-MS). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced docu
17、ment (including any amendments) applies. EN 13804, Foodstuffs Determination of trace elements Performance criteria, general considerations and sample preparation 3 Principle Iodine compounds are extracted with a strong alkaline reagent at elevated temperature. After removing un-dissolved components,
18、 the nebulized solution is atomized and ionized in an inductively coupled argon plasma. The ions are extracted from the plasma by a system of sampler and skimmer cones, separated in a mass spectrometer on the basis of their mass/charge ratio and determined using a pulse counting detector system. WAR
19、NING The use of this European Standard may involve hazardous materials, operations and equipment. This European Standard does not purport to address all the safety problems associated with its use. It is the responsibility of the user of this European Standard to establish appropriate safety and hea
20、lth practices and determine the applicability or regulatory limitations prior to use. 4 Reagents 4.1 General The concentration of iodine in the reagents and water used shall be low enough not to affect the results of the determination, e.g. different qualities of TMAH are available. It is important
21、to check, that the iodine content is low enough for the analysis. 4.2 Tetramethylammonium hydroxide (TMAH = (CH3)4N+OH-) solution, mass concentration = 250 g/l, (mass fraction w = 25 %), suitable for trace analysis with an iodine content of less than 1 g/l. 4.3 Diluted tetramethylammonium hydroxide
22、(TMAH) solution Dilute TMAH solution for preparing the zero member compensation and calibration solutions, with a concentration to suit that of the sample solution (see 7.3). Prepare a 0,5 % TMAH solution by diluting 1,0 ml of TMAH solution (4.2) to 50 ml with water. 4.4 Stock solutions 4.4.1 Genera
23、l Commercial stock solutions may be used as an alternative to the solutions described below. EN 15111:2007 (E) 5 4.4.2 Iodine stock solution (KIO3), = 1 000 mg/l, purity: mass fraction w 99,5 %. Dissolve 1,686 4 g of potassium iodate in water and dilute to 1 l with water. 4.4.3 Tellurium stock solut
24、ion, = 1 000 mg/l. Dissolve 1,250 8 g of tellurium dioxide (TeO2) in 4 mol/l hydrochloric acid and dilute to 1 l with water. 4.5 Standard solutions 4.5.1 Iodine standard solution, = 10 mg/l. Pipette 1 ml of the iodine stock solution (4.4.2) into a 100 ml volumetric flask and dilute to the mark with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN151112007ENFOODSTUFFSDETERMINATIONOFTRACEELEMENTSDETERMINATIONOFIODINEBYICPMSINDUCTIVELYCOUPLEDPLASMAMASSSPECTROMETRY

链接地址:http://www.mydoc123.com/p-714782.html