EN 14637-2007 en Building hardware - Electrically controlled hold-open systems for fire smoke door assemblies - Requirements test methods application and maintenance《建筑五金件 防火门 防烟门组.pdf
《EN 14637-2007 en Building hardware - Electrically controlled hold-open systems for fire smoke door assemblies - Requirements test methods application and maintenance《建筑五金件 防火门 防烟门组.pdf》由会员分享,可在线阅读,更多相关《EN 14637-2007 en Building hardware - Electrically controlled hold-open systems for fire smoke door assemblies - Requirements test methods application and maintenance《建筑五金件 防火门 防烟门组.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 14637:2007Building hardware Electrically controlled hold-open systems for fire/smoke door assemblies Requirements, test methods, application and maintenanceICS 91.060.50; 91.190g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g
2、59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 14637:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2008 BSI 2008ISBN 978 0 580 53506 2National forewordThis British Stand
3、ard is the UK implementation of EN 14637:2007.The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/4, Building hardware.A list of organizations represented on this committee can be obtained o
4、n request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda issued since publicationDate C
5、ommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14637November 2007ICS 91.060.50; 91.190English VersionBuilding hardware - Electrically controlled hold-open systems forfire/smoke door assemblies - Requirements, test methods,application and maintenanceQuincaillerie pour le btiment - Systmes d
6、e retenuecontrls lectriquement pour blocs-portes, coupe-feu oupare-fume - Exigences, mthode dessai, mise en uvreet maintenanceSchlsser und Baubeschlge - Elektrisch gesteuerteFeststellanlagen fr Feuer-/Rauchschutztren -Anforderungen, Prfverfahren, Anwendung und WartungThis European Standard was appro
7、ved by CEN on 30 September 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
8、standards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notifie
9、d to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, N
10、etherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation
11、 in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14637:2007: EEN 14637:2007 (E) 2 Contents Page Foreword5 Introduction .6 1 Scope 9 2 Normative references 9 3 Terms, definitions and abbreviated term 11 4 Classification13 4.1 Coding system .13 4.2 Category of use (
12、first digit).13 4.3 Durability (second digit)13 4.4 Door type (third digit) 13 4.5 Suitability for use on fire/smoke door assemblies (fourth digit)14 4.6 Safety (fifth digit) .14 4.7 Corrosion resistance (sixth digit) 14 4.8 Example of classification14 5 Requirements and test methods for components
13、of a hold-open system 15 5.1 General15 5.2 Fire detectors .15 5.2.1 Smoke detectors15 5.2.2 Heat detectors15 5.2.3 Resetting the detectors.15 5.3 Power supply units16 5.3.1 All power supply units 16 5.3.2 For power supply units with stand-by parallel operation16 5.4 Control units.17 5.4.1 General17
14、5.4.2 Control units in stand-alone hold-open systems (single-line systems) 17 5.4.3 Control units in fire detection and fire alarm systems (multi-line systems) .17 5.5 Hold-open devices.18 5.5.1 General18 5.5.2 Hold-open devices for swing doors.18 5.5.3 Hold-open devices for sliding doors, lifting d
15、oors, industrial doors and roller shutters 18 5.5.4 Automatic door operators.19 5.5.5 Low energy/power assisted swing door operators19 5.5.6 Free-swing door closers .20 5.6 Auxiliary equipment 20 5.6.1 Manual control push-buttons and switches .20 5.6.2 Presence sensors (electro-sensitive protective
16、equipment) 20 5.6.3 Door position sensors.21 5.6.4 Remote indicating devices .21 5.6.5 Manual reset.21 6 Requirements for the hold-open system.21 6.1 Design and performance.21 6.2 Product information.22 6.2.1 General22 6.2.2 For installation and maintenance.22 6.2.3 For initial hold-open system test
17、 .23 6.3 Requirements not covered under Clause 5 23 6.4 Electromagnetic compatibility (EMC) 23 BS EN 14637:2007EN 14637:2007 (E) 3 6.5 Additional design requirements for connection of components to fire alarm systems 24 6.6 Electrical safety .24 6.7 Durability 24 6.8 Environmental behaviour .25 6.8.
18、1 Dry heat 25 6.8.2 Cold.25 6.8.3 Damp heat, steady state (operational) 25 6.8.4 Corrosion .25 6.8.5 Vibration .25 6.9 Supply voltage variations.25 7 System tests 25 7.1 General .25 7.2 Test apparatus .26 7.3 Theoretical analysis 27 7.4 Test methods .27 7.4.1 General .27 7.4.2 Design verification 28
19、 7.4.3 Performance tests .28 7.4.4 Check of switching device capabilities of the control unit.30 7.4.5 Short-circuit test30 7.4.6 Electrical safety tests30 7.4.7 Electromagnetic compatibility (EMC) tests 30 7.4.8 Environmental tests 31 7.4.9 Corrosion test 32 7.4.10 Vibration test, sinusoidal (opera
20、tional).33 7.4.11 Vibration test, sinusoidal (endurance)33 8 Marking.35 8.1 Components.35 8.2 Hold-open system .35 Annex A (informative) Recommendations for planning and design of the hold-open system36 A.1 General .36 A.2 Restrictions36 A.3 Detectors 36 A.3.1 Selection of detector type 36 A.3.2 Pos
21、itioning and number of detectors37 A.4 Selection of hold-open device .43 A.4.1 General .43 A.4.2 Swing doors .43 A.4.3 Sliding doors44 A.4.4 Roller shutter and lifting doors44 A.4.5 Automatic doors 44 A.5 Manual release and manual control 44 A.5.1 General .44 A.5.2 Location of switch/push-button.45
22、A.6 Interconnecting cables .45 A.7 Guidance on competence and responsibilities for individual installations in individual buildings.45 A.7.1 Planning .45 A.7.2 Installation45 Annex B (informative) Recommendations for installation and fixing of the hold-open system46 Annex C (informative) Recommendat
23、ions for acceptance inspection of the hold-open system 47 Annex D (informative) Acceptance inspection report form .48 Annex E (informative) Recommendations for usage and maintenance of the hold-open system 50 E.1 Usage of installations .50 E.1.1 General .50 E.1.2 Periodic inspection .50 BS EN 14637:
24、2007EN 14637:2007 (E) 4 E.2 Routine site inspection report form.50 Annex F (informative) Evaluation of conformity 52 F.1 General52 F.1.1 Introduction52 F.1.2 Initial type test52 F.1.3 Characteristics.52 F.1.4 Use of historical data 53 F.1.5 Treatment of calculated values and design 53 F.1.6 Sampling
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN146372007ENBUILDINGHARDWAREELECTRICALLYCONTROLLEDHOLDOPENSYSTEMSFORFIRESMOKEDOORASSEMBLIESREQUIREMENTSTESTMETHODSAPPLICATIONANDMAINTENANCE

链接地址:http://www.mydoc123.com/p-714361.html