EN 843-3-2005 en Advanced technical ceramics - Mechanical properties of monolithic ceramics at room temperature - Part 3 Determination of subcritical crack growth parameters from c.pdf
《EN 843-3-2005 en Advanced technical ceramics - Mechanical properties of monolithic ceramics at room temperature - Part 3 Determination of subcritical crack growth parameters from c.pdf》由会员分享,可在线阅读,更多相关《EN 843-3-2005 en Advanced technical ceramics - Mechanical properties of monolithic ceramics at room temperature - Part 3 Determination of subcritical crack growth parameters from c.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 843-3:2005Advanced technical ceramics Mechanical properties of monolithic ceramics at room temperature Part 3: Determination of subcritical crack growth parameters from constant stressing rate flexural strength testsThe European Standard EN 843-3:2005 has the status of a Britis
2、h StandardICS 81.060.30g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 843-3:2005This British Standard was published under the authority of th
3、e Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 978 0 580 49982 1National forewordThis British Standard was published by BSI. It is the UK implementation of EN 843-3:2005. It supersedes DD ENV 843-3:1997 which is withdrawn.The UK participation in its preparation was entrust
4、ed to Technical Committee RPI/13, Advanced technical ceramics.A list of organizations represented on RPI/13 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Complianc
5、e with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 843-3 June 2005 ICS 81.060.30 Supersedes ENV 843-3:1996 English version Advanced technical ceramics - Mechanical prope
6、rties of monolithic ceramics at room temperature - Part 3: Determination of subcritical crack growth parameters from constant stressing rate flexural strength tests Cramiques techniques avances - Proprits mcaniques des cramiques monolithiques temprature ambiante - Partie 3: Dtermination des paramtre
7、s de propagation sous-critique des fissures partir des essais de rsistance la flexion raliss vitesse de contrainte constante Hochleistungskeramik - Mechanische Eigenschaften monolithischer Keramik bei Raumtemperatur - Teil 3: Bestimmung der Parameter des unterkritischen Risswachstums aus Biegefestig
8、keitsprfungen mit konstanter Spannungsrate This European Standard was approved by CEN on 14 April 2005. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
9、 Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
10、under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary,
11、 Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Sta
12、ssart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 843-3:2005: EEN 843-3:2005 (E) 2 Contents Page Foreword 3 1 Scope. 4 2 Normative references. 4 3 Terms and definitions 4 4 Significance and use 5 5 Appa
13、ratus 6 5.1 Test jig. 6 5.2 Environmental control 7 5.3 Test machine. 7 5.4 Linear measuring devices 7 5.5 Drying oven. 7 5.6 Humidity measuring device . 8 6 Test pieces 8 7 Test procedure 8 8 Calculation 9 9 Precision and interferences. 10 10 Report 11 Annex A (informative) Derivation of relationsh
14、ip for determination of subcritical crack growth parameters from constant stressing rate flexural strength tests 13 Bibliography 14 EN 843-3:2005 (E) 3 Foreword This document (EN 843-3:2005) has been prepared by Technical Committee CEN/TC 184 “Advanced technical ceramics”, the secretariat of which i
15、s held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2005, and conflicting national standards shall be withdrawn at the latest by December 2005. EN 843 Advanced technical cerami
16、cs Mechanical properties of monolithic ceramics at room temperature consists of six parts: Part 1: Determination of flexural strength; Part 2: Determination of Youngs modulus, shear modulus and Poissons ratio; Part 3: Determination of subcritical crack growth parameters from constant stressing rate
17、flexural strength tests; Part 4: Vickers, Knoop and Rockwell superficial hardness; Part 5: Statistical analysis; Part 6: Guide for fractographic examination. This document supersedes ENV843-3:1996. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followi
18、ng countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
19、Switzerland and United Kingdom. EN 843-3:2005 (E) 4 1 Scope This European Standard specifies a method for the determination of subcritical crack growth parameters of advanced monolithic technical ceramics in the temperature range 15 C to 30 C by measuring the dependence of mean fracture strength on
20、the rate of loading. The method is based on strength test procedures described in EN 843-1. This European Standard is not applicable to test pieces with artificially introduced flaws or cracks. 2 Normative references The following referenced documents are indispensable for the application of this do
21、cument. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 843-1, Advanced technical ceramics Mechanical properties of monolithic ceramics at room temperature Part 1: Determination of flex
22、ural strength EN ISO 7500-1, Metallic materials Verification of static uniaxial testing machines Part 1: Tension/compression testing machines Verification and calibration of the force measuring system (ISO 7500-1:2004) EN ISO/IEC 17025, General requirements for the competence of testing and calibrat
23、ion laboratories (ISO/IEC 17025:1999) ISO 3611, Micrometer callipers for external measurement ISO 4677-1, Atmospheres for conditioning and testing Determination of relative humidity Part 1: Aspirated psychrometer method ISO 4677-2, Atmospheres for conditioning and testing Determination of relative h
24、umidity Part 2: Whirling psychrometer method 3 Terms and definitions For the purposes of this European Standard, the following terms and definitions apply. 3.1 nominal flexural strength maximum nominal stress at the instant of failure supported by the material when loaded in linear elastic bending 3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN84332005ENADVANCEDTECHNICALCERAMICSMECHANICALPROPERTIESOFMONOLITHICCERAMICSATROOMTEMPERATUREPART3DETERMINATIONOFSUBCRITICALCRACKGROWTHPARAMETERSFROMCPDF

链接地址:http://www.mydoc123.com/p-712849.html