EN 2349-312-2006 en Aerospace series - Requirements and test procedures for relays and contactors - Part 312 Electrical service life - Mixed load《航空航天系列 继电器和电流接触器要求和试验程序 第312部分 电器使.pdf
《EN 2349-312-2006 en Aerospace series - Requirements and test procedures for relays and contactors - Part 312 Electrical service life - Mixed load《航空航天系列 继电器和电流接触器要求和试验程序 第312部分 电器使.pdf》由会员分享,可在线阅读,更多相关《EN 2349-312-2006 en Aerospace series - Requirements and test procedures for relays and contactors - Part 312 Electrical service life - Mixed load《航空航天系列 继电器和电流接触器要求和试验程序 第312部分 电器使.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 2349-312:2006Aerospace series Requirements and test procedures for relays and contactors Part 312: Electrical service life Mixed loadThe European Standard EN 2349-312:2006 has the status of a British StandardICS 49.060g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54
2、g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 2349-312:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 978 0
3、580 50027 5National forewordThis British Standard was published by BSI. It is the UK implementation of EN 2349-312:2006. The UK participation in its preparation was entrusted by Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology, to Panel ACE/6/-/4, Aerospace Switchin
4、g devices.A list of organizations represented on ACE/6/-/4 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity
5、from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 2349-312October 2006ICS 49.060English VersionAerospace series - Requirements and test procedures for relaysand contactors - Part 312: Electrical service life - Mixed load
6、Srie arospatiale - Exigences et mthodes dessais desrelais et contacteurs - Partie 312 : Pouvoirs decommutation - Charges combinesLuft- und Raumfahrt - Anforderungen und Prfverfahren frRelais und Schaltschtze - Teil 312: ElektrischeLebensdauer - MischlastThis European Standard was approved by CEN on
7、19 May 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obt
8、ained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secre
9、tariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portug
10、al, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means rese
11、rvedworldwide for CEN national Members.Ref. No. EN 2349-312:2006: E2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Mounting method.4 4 Test procedures.4 5 Test criteria.6 6 Verification tests6 EN 2349-312:20063 Foreword This document (EN 2349-312:2006) has been prepared by the AeroSpa
12、ce and Defence Industries Association of europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior t
13、o its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2007, and conflicting national standards shall be withdrawn at the latest by April 2007. According to the CEN/CENEL
14、EC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta
15、, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 2349-312:20064 1 Scope This standard specifies a method for testing the electrical service life - mixed load of relays and contactors. It shall be used together with EN 2349-10
16、0. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2349-100, Aerospace
17、series Requirements and test procedures for relays and contactors Part 100: General requirements 1)EN 2349-302, Aerospace series Requirements and test procedures for relays and contactors Part 302: Insulation resistance EN 2349-303, Aerospace series Requirements and test procedures for relays and co
18、ntactors Part 303: Dielectric strength EN 2349-307, Aerospace series Requirements and test procedures for relays and contactors Part 307: Contact voltage drop EN 2349-412, Aerospace series Requirements and test procedures for relays and contactors Part 412: Seal 3 Mounting method The relay or contac
19、tor shall be wired in accordance with EN 2349-100 and the rated contact load. The relay or contactor shall be mounted and placed in an air circulating heating cabinet. 4 Test procedures 4.1 Each normally closed and normally open contact shall connect, conduct and disconnect the specified loads. The
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN23493122006ENAEROSPACESERIESREQUIREMENTSANDTESTPROCEDURESFORRELAYSANDCONTACTORSPART312ELECTRICALSERVICELIFEMIXEDLOAD

链接地址:http://www.mydoc123.com/p-709957.html