EN 203-2-1-2014 en Gas heated catering equipment - Part 2-1 Specific requirements - Open burners and wok burners《燃气加热的餐饮设备 第2部分 1 特殊要求 一般安全规则 打开燃烧器和工作燃烧器》.pdf
《EN 203-2-1-2014 en Gas heated catering equipment - Part 2-1 Specific requirements - Open burners and wok burners《燃气加热的餐饮设备 第2部分 1 特殊要求 一般安全规则 打开燃烧器和工作燃烧器》.pdf》由会员分享,可在线阅读,更多相关《EN 203-2-1-2014 en Gas heated catering equipment - Part 2-1 Specific requirements - Open burners and wok burners《燃气加热的餐饮设备 第2部分 1 特殊要求 一般安全规则 打开燃烧器和工作燃烧器》.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 203-2-1:2014Gas heated catering equipmentPart 2-1: Specific requirements Openburners and wok burnersBS EN 203-2-1:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 203-2-1:2014. Itsupersedes BS EN 203-2-1:2005 which is withdrawn
2、.The UK participation in its preparation was entrusted to TechnicalCommittee GSE/19, Catering equipment (gas).A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users
3、 are responsible for its correctapplication. The British Standards Institution 2015. Published by BSI StandardsLimited 2015ISBN 978 0 580 82212 4ICS 97.040.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the
4、Standards Policy and Strategy Committee on 31 January 2015.Amendments issued since publicationDate Text affectedBS EN 203-2-1:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 203-2-1 December 2014 ICS 97.040.20 Supersedes EN 203-2-1:2005English Version Gas heated catering equipment - Part 2-
5、1: Specific requirements - Open burners and wok burners Appareils de cuisson professionnelle utilisant les combustibles gazeux - Partie 2-1: Exigences particulires - Brleurs dcouverts et woks Grokchengerte fr gasfrmige Brennstoffe - Teil 2-1: Spezifische Anforderungen - Offene Brenner und Wok-Brenne
6、r This European Standard was approved by CEN on 8 November 2014. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical r
7、eferences concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a
8、 CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Maced
9、onia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EURO
10、PISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 203-2-1:2014 EBS EN 203-2-1:2014EN 203-2-1:2014 (E) 2 Contents Page Foreword 5 1 Scope
11、 6 2 Normative references 6 3 Terms and definitions .6 4 Classification 6 5 Constructional requirements 6 5.1 General 6 5.1.1 Conversion to different gases 6 5.1.2 Materials and methods of construction 7 5.1.3 Use, cleaning and maintenance .7 5.1.4 Gas connections 7 5.1.5 Soundness 7 5.1.6 Supply of
12、 combustion air and evacuation of combustion products 7 5.1.7 Flame visibility .7 5.1.8 Electrical safety7 5.1.9 Construction requirements for gas cylinder compartment .8 5.2 Particular requirements for components in the gas circuit 8 5.2.1 General 8 5.2.2 Gas rate control and shut-off device .8 5.2
13、.3 Auxiliary equipment 8 5.2.4 Burners .8 5.2.5 Gas rate adjusters9 5.3 Particular requirements 9 5.3.1 Food spillage 9 5.3.2 Stability and mechanical safety .9 6 Performance requirements .9 6.1 Soundness 9 6.1.1 Soundness of the gas circuit 9 6.1.2 Soundness of combustion product circuit of type B
14、appliances .9 6.2 Obtaining the gas rate .9 6.2.1 Nominal heat input (Qn) .9 6.2.2 Full calorific rate 9 6.2.3 Reduced heat input9 6.2.4 Ignition burner heat input .9 6.3 Safety of operation . 10 6.3.1 Burners 10 6.3.2 Temperature limits 10 6.3.3 Ignition cross-lighting - flame stability 10 6.3.4 Co
15、mbustion products safety devices for type B11BSappliances . 10 6.3.5 Pre-purge . 11 6.4 Influence of burners on each other. 11 6.5 Auxiliary equipment . 11 6.5.1 Flame shut off device . 11 6.5.2 Ignition device . 11 6.6 Air proving device. 11 6.6.1 General . 11 6.6.2 Supervision of the combustion ai
16、r or combustion products rate . 11 6.6.3 Supervision of the combustion air pressure or combustion products pressure 12 6.6.4 Air/gas ratio controls 12 6.7 Combustion . 12 6.7.1 All appliances (in calm air) 12 6.7.2 Special conditions 12 BS EN 203-2-1:2014EN 203-2-1:2014 (E) 3 6.7.101 Abnormal use re
17、asonably foreseeable 12 6.8 Particular requirements 12 6.8.1 Stability and mechanical safety . 12 6.8.2 Pressurized parts . 12 6.8.3 Lack of heat-bearing fluid . 12 6.9 Auxiliary energy . 12 6.9.1 General 12 6.9.2 Electrical energy fluctuation 12 6.9.3 Other auxiliary energy . 12 6.10 Rational use o
18、f energy 12 6.10.101 Open burners 13 6.11 Operating requirements - Temperature of the LPG cylinder and its compartment 13 6.11.1 Temperature of the walls of the compartment . 13 6.11.2 Temperature of the LPG cylinder . 13 7 Test conditions 13 7.1 General 13 7.1.1 Characteristics of the test gases .
19、13 7.1.2 Requirements for making up test gases . 13 7.1.3 Test room . 13 7.1.4 Preparation of the appliance 13 7.1.5 Practical method of test 13 7.1.6 Test pressures . 13 7.1.7 Carrying out the tests 13 7.2 Soundness . 14 7.2.1 Soundness of the gas circuit . 14 7.2.2 Soundness of the combustion circ
20、uit and correct evacuation of the combustion products for type B appliances 14 7.3 Obtaining gas rates . 14 7.3.1 General 14 7.3.2 Nominal heat input 14 7.3.3 Full rate . 14 7.3.4 Reduced rate 15 7.4 Operational safety . 15 7.4.1 Burners . 15 7.4.2 Limit temperatures 15 7.4.3 Ignition - cross- light
21、ing - flame stability 15 7.5 Auxiliary equipment 17 7.5.1 Flame shut off device 17 7.5.2 Ignition device 17 7.6 Combustion 17 7.6.1 General 17 7.6.2 Tests carried out under normal conditions 17 7.6.3 Specific test for type B appliances 21 7.6.4 Test with sooting limit gas 21 7.7 Air-proving device .
22、 21 7.7.1 General 21 7.7.2 Supervision of the combustion air or the combustion products rate 21 7.7.3 Supervision of the combustion air or the combustion products pressure . 22 7.8 Special tests . 22 7.8.1 Stability and mechanical safety . 22 7.8.2 Pressurized parts . 22 7.8.3 Lack of heat bearing f
23、luid . 22 7.8.101 Spillage 22 7.9 Test method - Overheating of the LPG cylinder and its compartment 22 7.101 Rational use of energy 22 7.101.1 General 22 7.101.2 Test. 23 8 Designation 24 9 Marking and instructions 24 BS EN 203-2-1:2014EN 203-2-1:2014 (E) 4 9.1 General . 24 9.2 Marking on the applia
24、nce . 24 9.2.1 Data plates and labels 24 9.2.2 Other marking on the appliance 24 9.3 Instructions . 24 9.3.1 General . 24 9.3.2 Instructions for use and maintenance 24 9.3.3 Instructions for installation and adjustment 24 9.3.4 Instructions for conversion to different gases 24 9.4 Packaging 24 Annex
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN203212014ENGASHEATEDCATERINGEQUIPMENTPART21SPECIFICREQUIREMENTSOPENBURNERSANDWOKBURNERS 燃气 加热 餐饮 设备

链接地址:http://www.mydoc123.com/p-709644.html