1、BRITISH STANDARDBS EN 14175-3:2003 Fume cupboards Part 3: Type test methodsICS 71.040.10; 91.140.30nullnull nullnullnullnullnullnullnull nullnullnullnullnullnullnull nullnullnull nullnullnullnullnullnullnullnullnullnull nullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnull
2、nullnullnullnullnullnullnullnullnull nullnullnullIncorporating corrigendum February 2014National forewordThis British Standard is the UK implementation of EN 14175-3:2003. Together with BS EN 14175-1:2003, BS EN 14175-2:2003, BS EN 14175-4:2004, DD CEN/TS 14175-5:2006, BS EN 14175-6:2006 and BS EN 1
3、4175-7:2012, it supersedes BS 7258-1:1994, BS 7258-2:1994, BS 7258-3:1994 and BS 7258-4:1994 which are withdrawn.The UK committee advises that prior to purchasing a fume cupboard, a risk assessment should be performed to assess the risks associated with the substances that are to be manipulated. Thi
4、s would ensure that the fume cupboard is suitable for its intended purpose and that current exposure limits for toxic substances are not exceeded. It is suggested, therefore, that users may need to draw up a specification appropriate to their particular requirements, within the overall permissible l
5、imits of this standard and the information on installation included in the National Annex. For users with little experience of purchasing fume cupboards, it may be helpful for trade associations, employers bodies or other organizations associated with a particular activity to give guidance on a suit
6、able specification. An example would be Building Bulletin 88 from the Architects null Part 1: Vocabularynull Part2:Safetyand performance requirementsnull Part 3: Type test methodsnull Part 4: On-site test methodsnull Part 5: Recommendations for installation and maintenance (in preparation)null Part
7、6: Variable airvolume fume cupboards (in preparation)According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountriesare bound to implement this European Standard: Austria, Belgium,Czech Republic, Denmark, Finland,France, Germany, Greece, Hungary, Ice
8、land, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal,Slovakia, Spain,Sweden, Switzerland and the United Kingdom.EN 14175-3:20034IntroductionThe objective of this European Standard is to specify type test methods relevant to the assessment of the safetyand performance of fume cupboa
9、rds.EN 14175-3:200351 ScopeThis part of the European Standard EN 14175 specifies type test methods for the assessment of safety andperformance of fume cupboards. Relevant requirements are specified in Part 2 of this European Standard.Fortermsand their definitions EN 14175-1 applies. For safetyand pe
10、rformance requirements of fume cupboardsEN 14175-2 applies.NOTE For on-site test methods of fume cupboards, Part 4 of this European Standard is in preparation.For the testing of microbiological safety cabinetsEN 12469 applies.2 Normative referencesThis European Standardincorporates by dated or undat
11、ed reference, provisions from other publications. Thesenormative references arecited at the appropriate places in the text and the publications are listed hereafter. Fordated references, subsequent amendments to or revisions of any of these publications apply to this EuropeanStandard onlywhen incorp
12、orated in it byamendment or revision. For undated references the latest edition of thepublication referred to applies (including amendments).EN 12665, Light and lighting Basic termsand criteria for specifying lighting re quirements.EN 13150:2001,Workbenches for laboratories Dimensions, safety requir
13、ements and testmethods.EN 14175-1:2003,Fume cupboards Part 1: Vocabulary.EN 14175-2:2003,Fume cupboards Part 2: Safety and performance requirements.EN ISO 5167-1, Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: Gene
14、ral principles and requirements (ISO 5167-1:2003).EN ISO 12569, Thermalinsulation in buildings Determination of airchange in buildings Tracer gas dilutionmethod (ISO 12569:2000).3 Terms and definitionsFor the purposesof this European Standard, the definitionsgiven in EN 14175-1:2003 and the followin
15、g apply.3.1 plane of sashplane in the middle betweenthe innermost and the outermost screen surfaces of that part of the sash forming theupperboundary of the test sash opening.NOTE This definition replaces the definition given in EN14175-1:2003, 5.4.3.2 inner measurementplaneplane ofsash at the type
16、test opening, except where the plane of sash doesnot meet the work surface of the fumecupboard. In the latter case, it isusually a non-vertical plane bounded;null at the top by the lowestpoint of the upper edge of the type testopening in the plane of the sash;null at the bottom by the uppermost poin
17、t of the lower edge of the opening closest to the plane of sash;EN 14175-3:20036null at the sides bythe side edges of the opening.NOTE 1 See examples in Figures 1 and 2.NOTE 2 This definition replaces the definition given in EN14175-1:2003, 7.7.3.3 containmentfactor (CF )ratio of calculated concentr
18、ation of tracer gas in the workspace of the fume cupboard to the measuredconcentration in the inner orouter measurement plane.NOTE The containment factor is no constant value but depends on the extract volume flow rate and the measuredconcentration of tracer gas.4 Test room and general test conditio
19、ns4.1 Dimensions and constructionThe test room shall consist of an enclosure of cuboid shape, constructed of suitable materials,within an existingbuilding orlaboratory.The internal widthand length shall be not less than 4,0 m and the ceiling height not less than2,7 m.The ceiling and floor shall be l
20、evel and the room shall be dev oid of internal supports, internal walls or otherobstacles to the airflow.4.2 Test room conditionsThe room air temperature shall be (23 3)C. The make-up air temperature during measurementsshall be roomair temperature 1 C. Temperature gradients shall be avoided to the g
21、reatest possible extent. The make-up airshall be supplied at a distance greater than 2 m from the front of the fume cupboard.The test zone boundaryshall extend approx. 1,5 min front of the fume cupboard and approx. 1,0 m from the outersidewallsof the cupboard over the full room height.Roomextract ai
22、rshall be extracted symmetrically on the opposite side to the make-up air supply and from outsidethe testzone. The air speed shall be less than 0,1 m/s at the testzone boundaries.Care shall be taken regardinguncontrolled air streams and draughtsentering into the test room.Anydevice the temperature o
23、f which exceeds 40 C, except components which form part of the fume cupboardand/or the test equipment, shall be located outside the testzone boundaries.The air extracted from the test room shall be discharged to atmosphere in such a way as to prevent its re-entrainment in the make-up air.4.3 Fume cu
24、pboard installationThe fume cupboard shall be installed centrally on a wallwith its back to the wall.The test shall be carried out on the fume cupboard installed in the test room in accordance with the manufacturersinstallation instructions.4.4 Testconditions4.4.1 GeneralNo person otherthan the oper
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1417532003ENFUMECUPBOARDSPART3TYPETESTMETHODS 通风 部分 型式 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-708767.html