EN 13167-2012 en Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification (Incorporates Amendment A1 2015)《建筑保温产品 工厂生产泡沫玻璃(CG)产品 规范》.pdf
《EN 13167-2012 en Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification (Incorporates Amendment A1 2015)《建筑保温产品 工厂生产泡沫玻璃(CG)产品 规范》.pdf》由会员分享,可在线阅读,更多相关《EN 13167-2012 en Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification (Incorporates Amendment A1 2015)《建筑保温产品 工厂生产泡沫玻璃(CG)产品 规范》.pdf(52页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationThermal insulation products for buildings Factory made cellular glass (CG) products SpecificationBS EN 13167:2012+A1:2015BS EN 13167:2012+A1:2015National forewordThis British Standard is the UK implementation of EN 13167:2012+A1:2015. It supersedes BS EN 13167:2012, which is
2、 withdrawn.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1 is indicated by !“.The UK participation in its preparation was entrust
3、ed to Technical Committee B/540, Energy performance of materials components and buildings.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible f
4、or its correct application. The British Standards Institution 2015. Published by BSI Standards Limited 2015ISBN 978 0 580 86748 4ICS 91.100.60Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the Standards Polic
5、y and Strategy Committee on 28 February 2013.Amendments/corrigenda issued since publicationDate Text affected31 March 2015 Implementation of CEN amendment A1:2015BRITISH STANDARDEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13167:2012+A1 February 2015 ICS 91.100.60 Supersedes EN 13167:2012Eng
6、lish Version Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification Produits isolants thermiques pour le btiment - Produits manufacturs en verre cellulaire (CG) - Spcification Wrmedmmstoffe fr Gebude - Werkmig hergestellte Produkte aus Schaumglas (CG) -
7、 Spezifikation This European Standard was approved by CEN on 6 October 2012 and includes Amendment 1 approved by CEN on 15 December 2014. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a nationa
8、l standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A versio
9、n in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Cze
10、ch Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. E
11、UROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13167:2012+A1
12、:2015 E2 Contents Page Foreword 4 1 Scope 6 2 Normative references 6 3 Terms, definitions, symbols, units and abbreviated terms .7 4 Requirements 11 5 Test methods . 17 6 Designation code 19 7 Assessment and Verification of the Constancy of Performance (AVCP) . 20 8 Marking and labelling . 21 Annex
13、A (normative) Determination of the declared values of thermal resistance and thermal conductivity . 23 Annex B (normative) !Product type determination“ (!PTD“) and factory production control (FPC) . 25 Annex C (normative) CG multi-layered insulation products . 29 Annex D (informative) Additional pro
14、perties 31 Annex E (informative) Preparation of the test specimens to measure thermal conductivity . 34 Annex ZA (informative) !Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation“ 36 Bibliography . 47 Tables Table 1 Dimensional stability under spec
15、ified conditions 13 Table 2 Levels for compressive strength . 14 Table 3 Levels for bending strength . 15 Table 4 Levels for deformation under point load . 15 Table 5 Test methods, test specimens and conditions. 18 Table A.1 Values for k for one sided 90 % tolerance interval with a confidence level
16、of 90 % . 24 Table B.1 Minimum number of tests for !PTD“ and minimum product testing frequencies . 25 Table B.2 Minimum product testing frequencies for the reaction to fire characteristics 27 Table D.1 Test methods, test specimens, conditions and minimum testing frequencies . 32 Table ZA.1 Relevant
17、clauses for factory made cellular glass and intended use 36 Table ZA.2 Systems of AVCP . 38 Table ZA.3.1 Assignment of AVCP tasks for factory made cellular glass products under system 1 for reaction to fire and system 3 (see Table ZA.2) 38 Table ZA.3.2 Assignment of AVCP tasks for factory made cellu
18、lar glass products under system 3 (see Table ZA.2) 40 BS EN 13167:2012+A1:2015 EN 13167:2012+A1:2015 (E)3 Table ZA.3.3 Assignment of AVCP tasks for factory made cellular glass products under combined system 4 for reaction to fire and system 3 (see Table ZA.2) 41 Figures Figure ZA.1 Example CE markin
19、g information of products under AVCP system 1 and system 3 46 BS EN 13167:2012+A1:2015 EN 13167:2012+A1:2015 (E)4 Foreword This document (EN 13167:2012+A1:2015) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. Th
20、is European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2015, and conflicting national standards shall be withdrawn at the latest by November 2016. Attention is drawn to the possibility that some of
21、the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supp
22、orts essential requirements of EU Directive(s). !For relationship with EU Construction Products Regulation (CPR), see informative Annex ZA, which is an integral part of this standard.“ This document supersedes !EN 13167:2012“. This document includes Amendment 1 approved by CEN on 2014-12-15. The sta
23、rt and finish of text introduced or altered by amendment is indicated in the text by tags !“. Compared with EN 13167:2008, the main changes are: a) better harmonisation between the individual standards of the package (EN 13162 to EN 13171) on definitions, requirements, classes and levels; b) new nor
24、mative annex on multi-layered products; c) changes on some editorial and technical content and addition of information on some specific items, such as point load (move towards 4.3); compressive strength (additional levels); bending strength (additional levels); d) addition of links to EN 15715, Ther
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN131672012ENTHERMALINSULATIONPRODUCTSFORBUILDINGSFACTORYMADECELLULARGLASSCGPRODUCTSSPECIFICATIONINCORPORATESAMENDMENTA12015

链接地址:http://www.mydoc123.com/p-707371.html